Concrete block structural masonry beam shear design: theoretical and experimental analysis and recommendations to the brazilian standards

Detalhes bibliográficos
Autor(a) principal: PASQUANTONIO,R. D.
Data de Publicação: 2019
Outros Autores: PARSEKIAN,G. A., CAMACHO,J. S.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista IBRACON de Estruturas e Materiais
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000400884
Resumo: Abstract Beams are subject a flexure and shear, with the last as the theme of this research. The purpose of this paper is to analyze specifications for the shear design of concrete block structural masonry beams, based on an extensive literature review and experimental tests here reported. From this scope, specifications for revision of Brazilian standardization are suggested. In the theoretical part, literature review from both national and international researchers were considered and the specifications of Brazilian standards, in addition to North American, Australian, Canadian and European, ABNT NBR 15961-1/2011, ABNT NBR 6118/2014TMS 402/2016, AS3700/2001, CSA S304/2014 and EuroCode6.1/2001, respectively. To analyze and validate the specifications of the literature, an experimental program was carried out assessing ten concrete block masonry beams results tested mainly to shear loads. Two-course high beams with three vertical load positions (position a/d) and two transverse reinforcement rates were tested. The specifications from the Brazilian and European standards led to considerably higher results than the experimental results, while those presented in the standards TMS 402/2016, AS3700/2001, CSA S304/2014 and NBR6118/2014 lead to results close to those obtained experimentally. As a conclusion, it can be noted that the rupture pattern is similar to that expected for reinforced concrete beams, the cracks were conditioned by the position of the loading point and by the mortar joints positions, the increase in the transverse reinforcement ratio led to an increase in the shear force. Results indicate that the consideration of apparent increase in shear strength by the ratio M ⁄ (V∙d) is not consistent. Eliminating this recommendation, considering the masonry shear strength equal to 0.35 MPa, limiting the stirrups tension to 0.90 of fyk and considering the contribution of the longitudinal reinforcement, it was possible to estimate the shear value at the rupture of each beam between 73% to 106% of the values verified in the tests.
id IBRACON-1_2ae4cfc57b589437a728cc7a09c012c2
oai_identifier_str oai:scielo:S1983-41952019000400884
network_acronym_str IBRACON-1
network_name_str Revista IBRACON de Estruturas e Materiais
repository_id_str
spelling Concrete block structural masonry beam shear design: theoretical and experimental analysis and recommendations to the brazilian standardsbeammasonryreinforced masonryshearAbstract Beams are subject a flexure and shear, with the last as the theme of this research. The purpose of this paper is to analyze specifications for the shear design of concrete block structural masonry beams, based on an extensive literature review and experimental tests here reported. From this scope, specifications for revision of Brazilian standardization are suggested. In the theoretical part, literature review from both national and international researchers were considered and the specifications of Brazilian standards, in addition to North American, Australian, Canadian and European, ABNT NBR 15961-1/2011, ABNT NBR 6118/2014TMS 402/2016, AS3700/2001, CSA S304/2014 and EuroCode6.1/2001, respectively. To analyze and validate the specifications of the literature, an experimental program was carried out assessing ten concrete block masonry beams results tested mainly to shear loads. Two-course high beams with three vertical load positions (position a/d) and two transverse reinforcement rates were tested. The specifications from the Brazilian and European standards led to considerably higher results than the experimental results, while those presented in the standards TMS 402/2016, AS3700/2001, CSA S304/2014 and NBR6118/2014 lead to results close to those obtained experimentally. As a conclusion, it can be noted that the rupture pattern is similar to that expected for reinforced concrete beams, the cracks were conditioned by the position of the loading point and by the mortar joints positions, the increase in the transverse reinforcement ratio led to an increase in the shear force. Results indicate that the consideration of apparent increase in shear strength by the ratio M ⁄ (V∙d) is not consistent. Eliminating this recommendation, considering the masonry shear strength equal to 0.35 MPa, limiting the stirrups tension to 0.90 of fyk and considering the contribution of the longitudinal reinforcement, it was possible to estimate the shear value at the rupture of each beam between 73% to 106% of the values verified in the tests.IBRACON - Instituto Brasileiro do Concreto2019-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000400884Revista IBRACON de Estruturas e Materiais v.12 n.4 2019reponame:Revista IBRACON de Estruturas e Materiaisinstname:Instituto Brasileiro do Concreto (IBRACON)instacron:IBRACON10.1590/s1983-41952019000400010info:eu-repo/semantics/openAccessPASQUANTONIO,R. D.PARSEKIAN,G. A.CAMACHO,J. S.eng2019-09-19T00:00:00Zoai:scielo:S1983-41952019000400884Revistahttp://www.revistas.ibracon.org.br/index.php/riemhttps://old.scielo.br/oai/scielo-oai.phpeditores.riem@gmail.com||arlene@ibracon.org.br1983-41951983-4195opendoar:2019-09-19T00:00Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)false
dc.title.none.fl_str_mv Concrete block structural masonry beam shear design: theoretical and experimental analysis and recommendations to the brazilian standards
title Concrete block structural masonry beam shear design: theoretical and experimental analysis and recommendations to the brazilian standards
spellingShingle Concrete block structural masonry beam shear design: theoretical and experimental analysis and recommendations to the brazilian standards
PASQUANTONIO,R. D.
beam
masonry
reinforced masonry
shear
title_short Concrete block structural masonry beam shear design: theoretical and experimental analysis and recommendations to the brazilian standards
title_full Concrete block structural masonry beam shear design: theoretical and experimental analysis and recommendations to the brazilian standards
title_fullStr Concrete block structural masonry beam shear design: theoretical and experimental analysis and recommendations to the brazilian standards
title_full_unstemmed Concrete block structural masonry beam shear design: theoretical and experimental analysis and recommendations to the brazilian standards
title_sort Concrete block structural masonry beam shear design: theoretical and experimental analysis and recommendations to the brazilian standards
author PASQUANTONIO,R. D.
author_facet PASQUANTONIO,R. D.
PARSEKIAN,G. A.
CAMACHO,J. S.
author_role author
author2 PARSEKIAN,G. A.
CAMACHO,J. S.
author2_role author
author
dc.contributor.author.fl_str_mv PASQUANTONIO,R. D.
PARSEKIAN,G. A.
CAMACHO,J. S.
dc.subject.por.fl_str_mv beam
masonry
reinforced masonry
shear
topic beam
masonry
reinforced masonry
shear
description Abstract Beams are subject a flexure and shear, with the last as the theme of this research. The purpose of this paper is to analyze specifications for the shear design of concrete block structural masonry beams, based on an extensive literature review and experimental tests here reported. From this scope, specifications for revision of Brazilian standardization are suggested. In the theoretical part, literature review from both national and international researchers were considered and the specifications of Brazilian standards, in addition to North American, Australian, Canadian and European, ABNT NBR 15961-1/2011, ABNT NBR 6118/2014TMS 402/2016, AS3700/2001, CSA S304/2014 and EuroCode6.1/2001, respectively. To analyze and validate the specifications of the literature, an experimental program was carried out assessing ten concrete block masonry beams results tested mainly to shear loads. Two-course high beams with three vertical load positions (position a/d) and two transverse reinforcement rates were tested. The specifications from the Brazilian and European standards led to considerably higher results than the experimental results, while those presented in the standards TMS 402/2016, AS3700/2001, CSA S304/2014 and NBR6118/2014 lead to results close to those obtained experimentally. As a conclusion, it can be noted that the rupture pattern is similar to that expected for reinforced concrete beams, the cracks were conditioned by the position of the loading point and by the mortar joints positions, the increase in the transverse reinforcement ratio led to an increase in the shear force. Results indicate that the consideration of apparent increase in shear strength by the ratio M ⁄ (V∙d) is not consistent. Eliminating this recommendation, considering the masonry shear strength equal to 0.35 MPa, limiting the stirrups tension to 0.90 of fyk and considering the contribution of the longitudinal reinforcement, it was possible to estimate the shear value at the rupture of each beam between 73% to 106% of the values verified in the tests.
publishDate 2019
dc.date.none.fl_str_mv 2019-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000400884
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1983-41952019000400884
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/s1983-41952019000400010
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
publisher.none.fl_str_mv IBRACON - Instituto Brasileiro do Concreto
dc.source.none.fl_str_mv Revista IBRACON de Estruturas e Materiais v.12 n.4 2019
reponame:Revista IBRACON de Estruturas e Materiais
instname:Instituto Brasileiro do Concreto (IBRACON)
instacron:IBRACON
instname_str Instituto Brasileiro do Concreto (IBRACON)
instacron_str IBRACON
institution IBRACON
reponame_str Revista IBRACON de Estruturas e Materiais
collection Revista IBRACON de Estruturas e Materiais
repository.name.fl_str_mv Revista IBRACON de Estruturas e Materiais - Instituto Brasileiro do Concreto (IBRACON)
repository.mail.fl_str_mv editores.riem@gmail.com||arlene@ibracon.org.br
_version_ 1754193605670469632