Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers

Detalhes bibliográficos
Autor(a) principal: Andrade, Érica
Data de Publicação: 2013
Outros Autores: Braghirolli, Ana Maria Silveira, Instituto de Engenharia Nuclear
Tipo de documento: Artigo de conferência
Idioma: eng
Título da fonte: Repositório Institucional do IEN
Texto Completo: http://carpedien.ien.gov.br:8080/handle/ien/2399
Resumo: The commercialization and use of radiopharmaceuticals in Brazil are regulated by Agência Nacional de Vigilância Sanitária (ANVISA) which require Good Manufacturing Practices (GMP)certification for Radiopharmaceuticals Producer Centers. Quality Assurance Program should implement the GMP standards to ensure radiopharmaceuticals have requirements quality to proving its efficiency. Several aspects should be controlled within the Quality Assurance Programs, and one of them is the traceability of the Radionuclides Activity Measurement in radiopharmaceuticals doses. The quality assurance of activity measurements is fundamental to maintain both the efficiency of the nuclear medicine procedures and patient and exposed occupationally individuals safety. The radiation doses received by patients, during the nuclear medicine procedures, is estimated according to administered radiopharmaceuticals quantity. Therefore it is very important either the activity measurements performed in radiopharmaceuticals producer centers (RPC) as the measurements performed in nuclear medicine services are traceable to national standards. This paper aims to present an implementation program to provide trace ability to radionuclides activity measurements performed in the dose calibrators (well type ionization chambers) used in Radiopharmaceuticals Producer Center placed in different states in Brazil. The proposed program is based on the principles of GMP and ISO 17025 standards. According to dose calibrator performance, the RPC will be able to provide consistent, safe and effective radioactivity measurement to the nuclear medicine services.
id IEN_28bacb7c034f47d3cc94da4d6e1a9e98
oai_identifier_str oai:carpedien.ien.gov.br:ien/2399
network_acronym_str IEN
network_name_str Repositório Institucional do IEN
spelling Andrade, ÉricaBraghirolli, Ana Maria SilveiraInstituto de Engenharia Nuclear2018-06-07T16:34:19Z2018-06-07T16:34:19Z2013-11http://carpedien.ien.gov.br:8080/handle/ien/2399Submitted by Marcele Costal de Castro (costalcastro@gmail.com) on 2018-06-07T16:34:19Z No. of bitstreams: 1 Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers.pdf: 175538 bytes, checksum: 30f225cbe60997cb126bbaedc24bd15c (MD5)Made available in DSpace on 2018-06-07T16:34:19Z (GMT). No. of bitstreams: 1 Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers.pdf: 175538 bytes, checksum: 30f225cbe60997cb126bbaedc24bd15c (MD5) Previous issue date: 2013-11The commercialization and use of radiopharmaceuticals in Brazil are regulated by Agência Nacional de Vigilância Sanitária (ANVISA) which require Good Manufacturing Practices (GMP)certification for Radiopharmaceuticals Producer Centers. Quality Assurance Program should implement the GMP standards to ensure radiopharmaceuticals have requirements quality to proving its efficiency. Several aspects should be controlled within the Quality Assurance Programs, and one of them is the traceability of the Radionuclides Activity Measurement in radiopharmaceuticals doses. The quality assurance of activity measurements is fundamental to maintain both the efficiency of the nuclear medicine procedures and patient and exposed occupationally individuals safety. The radiation doses received by patients, during the nuclear medicine procedures, is estimated according to administered radiopharmaceuticals quantity. Therefore it is very important either the activity measurements performed in radiopharmaceuticals producer centers (RPC) as the measurements performed in nuclear medicine services are traceable to national standards. This paper aims to present an implementation program to provide trace ability to radionuclides activity measurements performed in the dose calibrators (well type ionization chambers) used in Radiopharmaceuticals Producer Center placed in different states in Brazil. The proposed program is based on the principles of GMP and ISO 17025 standards. According to dose calibrator performance, the RPC will be able to provide consistent, safe and effective radioactivity measurement to the nuclear medicine services.engInstituto de Engenharia NuclearIENBrasilINAC 2013Nuclear medicineRadiopharmaceuticalRadionuclidesMetrology ProgrammeImplementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centersinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjectVI INACinfo:eu-repo/semantics/openAccessreponame:Repositório Institucional do IENinstname:Instituto de Engenharia Nuclearinstacron:IENLICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2399/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52ORIGINALImplementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers.pdfImplementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers.pdfapplication/pdf175538http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2399/1/Implementation+of+a+Metrology+Programme+to+provide+traceability+for+Radionuclides+Activity+measurements+in+the+CNEN+Radiopharmaceuticals+Producers+Centers.pdf30f225cbe60997cb126bbaedc24bd15cMD51ien/2399oai:carpedien.ien.gov.br:ien/23992018-06-07 13:34:19.672Dspace IENlsales@ien.gov.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
dc.title.pt_BR.fl_str_mv Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers
title Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers
spellingShingle Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers
Andrade, Érica
INAC 2013
Nuclear medicine
Radiopharmaceutical
Radionuclides
Metrology Programme
title_short Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers
title_full Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers
title_fullStr Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers
title_full_unstemmed Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers
title_sort Implementation of a Metrology Programme to provide traceability for Radionuclides Activity measurements in the CNEN Radiopharmaceuticals Producers Centers
author Andrade, Érica
author_facet Andrade, Érica
Braghirolli, Ana Maria Silveira
Instituto de Engenharia Nuclear
author_role author
author2 Braghirolli, Ana Maria Silveira
Instituto de Engenharia Nuclear
author2_role author
author
dc.contributor.author.fl_str_mv Andrade, Érica
Braghirolli, Ana Maria Silveira
Instituto de Engenharia Nuclear
dc.subject.por.fl_str_mv INAC 2013
Nuclear medicine
Radiopharmaceutical
Radionuclides
Metrology Programme
topic INAC 2013
Nuclear medicine
Radiopharmaceutical
Radionuclides
Metrology Programme
dc.description.abstract.por.fl_txt_mv The commercialization and use of radiopharmaceuticals in Brazil are regulated by Agência Nacional de Vigilância Sanitária (ANVISA) which require Good Manufacturing Practices (GMP)certification for Radiopharmaceuticals Producer Centers. Quality Assurance Program should implement the GMP standards to ensure radiopharmaceuticals have requirements quality to proving its efficiency. Several aspects should be controlled within the Quality Assurance Programs, and one of them is the traceability of the Radionuclides Activity Measurement in radiopharmaceuticals doses. The quality assurance of activity measurements is fundamental to maintain both the efficiency of the nuclear medicine procedures and patient and exposed occupationally individuals safety. The radiation doses received by patients, during the nuclear medicine procedures, is estimated according to administered radiopharmaceuticals quantity. Therefore it is very important either the activity measurements performed in radiopharmaceuticals producer centers (RPC) as the measurements performed in nuclear medicine services are traceable to national standards. This paper aims to present an implementation program to provide trace ability to radionuclides activity measurements performed in the dose calibrators (well type ionization chambers) used in Radiopharmaceuticals Producer Center placed in different states in Brazil. The proposed program is based on the principles of GMP and ISO 17025 standards. According to dose calibrator performance, the RPC will be able to provide consistent, safe and effective radioactivity measurement to the nuclear medicine services.
description The commercialization and use of radiopharmaceuticals in Brazil are regulated by Agência Nacional de Vigilância Sanitária (ANVISA) which require Good Manufacturing Practices (GMP)certification for Radiopharmaceuticals Producer Centers. Quality Assurance Program should implement the GMP standards to ensure radiopharmaceuticals have requirements quality to proving its efficiency. Several aspects should be controlled within the Quality Assurance Programs, and one of them is the traceability of the Radionuclides Activity Measurement in radiopharmaceuticals doses. The quality assurance of activity measurements is fundamental to maintain both the efficiency of the nuclear medicine procedures and patient and exposed occupationally individuals safety. The radiation doses received by patients, during the nuclear medicine procedures, is estimated according to administered radiopharmaceuticals quantity. Therefore it is very important either the activity measurements performed in radiopharmaceuticals producer centers (RPC) as the measurements performed in nuclear medicine services are traceable to national standards. This paper aims to present an implementation program to provide trace ability to radionuclides activity measurements performed in the dose calibrators (well type ionization chambers) used in Radiopharmaceuticals Producer Center placed in different states in Brazil. The proposed program is based on the principles of GMP and ISO 17025 standards. According to dose calibrator performance, the RPC will be able to provide consistent, safe and effective radioactivity measurement to the nuclear medicine services.
publishDate 2013
dc.date.issued.fl_str_mv 2013-11
dc.date.accessioned.fl_str_mv 2018-06-07T16:34:19Z
dc.date.available.fl_str_mv 2018-06-07T16:34:19Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
status_str publishedVersion
format conferenceObject
dc.identifier.uri.fl_str_mv http://carpedien.ien.gov.br:8080/handle/ien/2399
url http://carpedien.ien.gov.br:8080/handle/ien/2399
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Instituto de Engenharia Nuclear
dc.publisher.initials.fl_str_mv IEN
dc.publisher.country.fl_str_mv Brasil
publisher.none.fl_str_mv Instituto de Engenharia Nuclear
dc.source.none.fl_str_mv reponame:Repositório Institucional do IEN
instname:Instituto de Engenharia Nuclear
instacron:IEN
reponame_str Repositório Institucional do IEN
collection Repositório Institucional do IEN
instname_str Instituto de Engenharia Nuclear
instacron_str IEN
institution IEN
bitstream.url.fl_str_mv http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2399/2/license.txt
http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/2399/1/Implementation+of+a+Metrology+Programme+to+provide+traceability+for+Radionuclides+Activity+measurements+in+the+CNEN+Radiopharmaceuticals+Producers+Centers.pdf
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
30f225cbe60997cb126bbaedc24bd15c
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Dspace IEN
repository.mail.fl_str_mv lsales@ien.gov.br
_version_ 1656026993839308800