Study Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracer

Detalhes bibliográficos
Autor(a) principal: SALGADO, William L.
Data de Publicação: 2013
Outros Autores: BRANDÃO, Luis Eduardo Barreira, william.otero@hotmail.com, brandao@ien.gov.br
Tipo de documento: Artigo de conferência
Idioma: por
Título da fonte: Repositório Institucional do IEN
Texto Completo: http://carpedien.ien.gov.br:8080/handle/ien/1787
Resumo: This paper aims to determinate the water flowrate using Time Transient and Cross-Correlation techniques. The detection system uses two NaI(Tl) detectors adequately positioned on the outside of pipe and a gamma-ray source (82Br radiotracer). The water flowrate measurements using Time Transient and Cross-Correlation techniques were compared to invasive conventional measurements of the flowmeter previously installed in pipeline. Discrepancies between Time Transient and Cross-Correlation techniques flowrate values were found to be less than 3% in relation to conventional ones.
id IEN_c3321a032dddcf1a850ec2b15461ccc0
oai_identifier_str oai:carpedien.ien.gov.br:ien/1787
network_acronym_str IEN
network_name_str Repositório Institucional do IEN
spelling SALGADO, William L.BRANDÃO, Luis Eduardo Barreirawilliam.otero@hotmail.combrandao@ien.gov.br2016-06-29T16:39:39Z2016-06-29T16:39:39Z2013http://carpedien.ien.gov.br:8080/handle/ien/1787Submitted by Sherillyn Lopes (sherillynmartins@yahoo.com.br) on 2016-06-29T16:39:39Z No. of bitstreams: 1 STUDY OF WATER FLOWRATE USING TIME TRANSIENT AND.pdf: 959494 bytes, checksum: bf060b54d434b47143fc985f390aff4a (MD5)Made available in DSpace on 2016-06-29T16:39:39Z (GMT). No. of bitstreams: 1 STUDY OF WATER FLOWRATE USING TIME TRANSIENT AND.pdf: 959494 bytes, checksum: bf060b54d434b47143fc985f390aff4a (MD5) Previous issue date: 2013This paper aims to determinate the water flowrate using Time Transient and Cross-Correlation techniques. The detection system uses two NaI(Tl) detectors adequately positioned on the outside of pipe and a gamma-ray source (82Br radiotracer). The water flowrate measurements using Time Transient and Cross-Correlation techniques were compared to invasive conventional measurements of the flowmeter previously installed in pipeline. Discrepancies between Time Transient and Cross-Correlation techniques flowrate values were found to be less than 3% in relation to conventional ones.porInstituto de Engenharia NuclearIENBrasilWater FlowrateTime TransientCross-CorrelationStudy Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracerinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObject2013info:eu-repo/semantics/openAccessreponame:Repositório Institucional do IENinstname:Instituto de Engenharia Nuclearinstacron:IENLICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/1787/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52ORIGINALSTUDY OF WATER FLOWRATE USING TIME TRANSIENT AND.pdfSTUDY OF WATER FLOWRATE USING TIME TRANSIENT AND.pdfapplication/pdf959494http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/1787/1/STUDY+OF+WATER+FLOWRATE+USING+TIME+TRANSIENT+AND.pdfbf060b54d434b47143fc985f390aff4aMD51ien/1787oai:carpedien.ien.gov.br:ien/17872016-06-29 13:39:39.848Dspace IENlsales@ien.gov.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
dc.title.pt_BR.fl_str_mv Study Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracer
title Study Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracer
spellingShingle Study Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracer
SALGADO, William L.
Water Flowrate
Time Transient
Cross-Correlation
title_short Study Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracer
title_full Study Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracer
title_fullStr Study Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracer
title_full_unstemmed Study Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracer
title_sort Study Of Water Flowrate Using Time Transient And Cross-Correlation Techniques With 82br Radiotracer
author SALGADO, William L.
author_facet SALGADO, William L.
BRANDÃO, Luis Eduardo Barreira
william.otero@hotmail.com
brandao@ien.gov.br
author_role author
author2 BRANDÃO, Luis Eduardo Barreira
william.otero@hotmail.com
brandao@ien.gov.br
author2_role author
author
author
dc.contributor.author.fl_str_mv SALGADO, William L.
BRANDÃO, Luis Eduardo Barreira
william.otero@hotmail.com
brandao@ien.gov.br
dc.subject.por.fl_str_mv Water Flowrate
Time Transient
Cross-Correlation
topic Water Flowrate
Time Transient
Cross-Correlation
dc.description.abstract.por.fl_txt_mv This paper aims to determinate the water flowrate using Time Transient and Cross-Correlation techniques. The detection system uses two NaI(Tl) detectors adequately positioned on the outside of pipe and a gamma-ray source (82Br radiotracer). The water flowrate measurements using Time Transient and Cross-Correlation techniques were compared to invasive conventional measurements of the flowmeter previously installed in pipeline. Discrepancies between Time Transient and Cross-Correlation techniques flowrate values were found to be less than 3% in relation to conventional ones.
description This paper aims to determinate the water flowrate using Time Transient and Cross-Correlation techniques. The detection system uses two NaI(Tl) detectors adequately positioned on the outside of pipe and a gamma-ray source (82Br radiotracer). The water flowrate measurements using Time Transient and Cross-Correlation techniques were compared to invasive conventional measurements of the flowmeter previously installed in pipeline. Discrepancies between Time Transient and Cross-Correlation techniques flowrate values were found to be less than 3% in relation to conventional ones.
publishDate 2013
dc.date.issued.fl_str_mv 2013
dc.date.accessioned.fl_str_mv 2016-06-29T16:39:39Z
dc.date.available.fl_str_mv 2016-06-29T16:39:39Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/conferenceObject
status_str publishedVersion
format conferenceObject
dc.identifier.uri.fl_str_mv http://carpedien.ien.gov.br:8080/handle/ien/1787
url http://carpedien.ien.gov.br:8080/handle/ien/1787
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Instituto de Engenharia Nuclear
dc.publisher.initials.fl_str_mv IEN
dc.publisher.country.fl_str_mv Brasil
publisher.none.fl_str_mv Instituto de Engenharia Nuclear
dc.source.none.fl_str_mv reponame:Repositório Institucional do IEN
instname:Instituto de Engenharia Nuclear
instacron:IEN
reponame_str Repositório Institucional do IEN
collection Repositório Institucional do IEN
instname_str Instituto de Engenharia Nuclear
instacron_str IEN
institution IEN
bitstream.url.fl_str_mv http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/1787/2/license.txt
http://carpedien.ien.gov.br:8080/xmlui/bitstream/ien/1787/1/STUDY+OF+WATER+FLOWRATE+USING+TIME+TRANSIENT+AND.pdf
bitstream.checksum.fl_str_mv 8a4605be74aa9ea9d79846c1fba20a33
bf060b54d434b47143fc985f390aff4a
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
repository.name.fl_str_mv Dspace IEN
repository.mail.fl_str_mv lsales@ien.gov.br
_version_ 1656026986672291840