Polyclonal anti T-lymphocyte antibody therapy monitoring in kidney transplant recipients: comparison of CD3+ T cell and total lymphocyte counts
Autor(a) principal: | |
---|---|
Data de Publicação: | 2018 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Einstein (São Paulo) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082018000400213 |
Resumo: | ABSTRACT Objective: To investigate the correlation between total lymphocyte and CD3+ T cell counts in peripheral blood in renal transplant patients treated with anti-thymocyte globulin, and discuss related outcomes. Methods: A single-center, retrospective study involving 226 patients submitted to kidney transplant between 2008 and 2013, and treated with anti-thymocyte globulin for induction or treatment of cellular rejection. Doses were adjusted according to CD3+ T cell or total lymphocyte counts in peripheral blood. Results: A total of 664 paired samples were analyzed. The Spearman's correlation coefficient was 0.416 (p<0.001) for all samples combined; the overall Kappa coefficient was 0.267 (p<0.001). Diagnostic parameters estimated based on total lymphocyte counts were also calculated using the number of CD3+ T cells (gold standard), with a cut off of >20 cells/mm3. Conclusion: Total lymphocyte and CD3+ T cell counts in peripheral blood are not equivalent monitoring strategies in anti-thymocyte globulin therapy. |
id |
IIEPAE-1_70ed079b625b13defa5acd718dd66835 |
---|---|
oai_identifier_str |
oai:scielo:S1679-45082018000400213 |
network_acronym_str |
IIEPAE-1 |
network_name_str |
Einstein (São Paulo) |
repository_id_str |
|
spelling |
Polyclonal anti T-lymphocyte antibody therapy monitoring in kidney transplant recipients: comparison of CD3+ T cell and total lymphocyte countsKidney transplantationImmunosuppressionT-lymphocytesMonitoring, immunologicReceptor-CD3 complex, antigen, T-cellABSTRACT Objective: To investigate the correlation between total lymphocyte and CD3+ T cell counts in peripheral blood in renal transplant patients treated with anti-thymocyte globulin, and discuss related outcomes. Methods: A single-center, retrospective study involving 226 patients submitted to kidney transplant between 2008 and 2013, and treated with anti-thymocyte globulin for induction or treatment of cellular rejection. Doses were adjusted according to CD3+ T cell or total lymphocyte counts in peripheral blood. Results: A total of 664 paired samples were analyzed. The Spearman's correlation coefficient was 0.416 (p<0.001) for all samples combined; the overall Kappa coefficient was 0.267 (p<0.001). Diagnostic parameters estimated based on total lymphocyte counts were also calculated using the number of CD3+ T cells (gold standard), with a cut off of >20 cells/mm3. Conclusion: Total lymphocyte and CD3+ T cell counts in peripheral blood are not equivalent monitoring strategies in anti-thymocyte globulin therapy.Instituto Israelita de Ensino e Pesquisa Albert Einstein2018-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082018000400213einstein (São Paulo) v.16 n.4 2018reponame:Einstein (São Paulo)instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)instacron:IIEPAE10.31744/einstein_journal/2018ao4278info:eu-repo/semantics/openAccessMachado,Fabiani PalagiVicari,Alessandra RosaSpuldaro,FábioCastro Filho,João Batista Saldanha deManfro,Roberto Cerattieng2018-11-26T00:00:00Zoai:scielo:S1679-45082018000400213Revistahttps://journal.einstein.br/pt-br/ONGhttps://old.scielo.br/oai/scielo-oai.php||revista@einstein.br2317-63851679-4508opendoar:2018-11-26T00:00Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE)false |
dc.title.none.fl_str_mv |
Polyclonal anti T-lymphocyte antibody therapy monitoring in kidney transplant recipients: comparison of CD3+ T cell and total lymphocyte counts |
title |
Polyclonal anti T-lymphocyte antibody therapy monitoring in kidney transplant recipients: comparison of CD3+ T cell and total lymphocyte counts |
spellingShingle |
Polyclonal anti T-lymphocyte antibody therapy monitoring in kidney transplant recipients: comparison of CD3+ T cell and total lymphocyte counts Machado,Fabiani Palagi Kidney transplantation Immunosuppression T-lymphocytes Monitoring, immunologic Receptor-CD3 complex, antigen, T-cell |
title_short |
Polyclonal anti T-lymphocyte antibody therapy monitoring in kidney transplant recipients: comparison of CD3+ T cell and total lymphocyte counts |
title_full |
Polyclonal anti T-lymphocyte antibody therapy monitoring in kidney transplant recipients: comparison of CD3+ T cell and total lymphocyte counts |
title_fullStr |
Polyclonal anti T-lymphocyte antibody therapy monitoring in kidney transplant recipients: comparison of CD3+ T cell and total lymphocyte counts |
title_full_unstemmed |
Polyclonal anti T-lymphocyte antibody therapy monitoring in kidney transplant recipients: comparison of CD3+ T cell and total lymphocyte counts |
title_sort |
Polyclonal anti T-lymphocyte antibody therapy monitoring in kidney transplant recipients: comparison of CD3+ T cell and total lymphocyte counts |
author |
Machado,Fabiani Palagi |
author_facet |
Machado,Fabiani Palagi Vicari,Alessandra Rosa Spuldaro,Fábio Castro Filho,João Batista Saldanha de Manfro,Roberto Ceratti |
author_role |
author |
author2 |
Vicari,Alessandra Rosa Spuldaro,Fábio Castro Filho,João Batista Saldanha de Manfro,Roberto Ceratti |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Machado,Fabiani Palagi Vicari,Alessandra Rosa Spuldaro,Fábio Castro Filho,João Batista Saldanha de Manfro,Roberto Ceratti |
dc.subject.por.fl_str_mv |
Kidney transplantation Immunosuppression T-lymphocytes Monitoring, immunologic Receptor-CD3 complex, antigen, T-cell |
topic |
Kidney transplantation Immunosuppression T-lymphocytes Monitoring, immunologic Receptor-CD3 complex, antigen, T-cell |
description |
ABSTRACT Objective: To investigate the correlation between total lymphocyte and CD3+ T cell counts in peripheral blood in renal transplant patients treated with anti-thymocyte globulin, and discuss related outcomes. Methods: A single-center, retrospective study involving 226 patients submitted to kidney transplant between 2008 and 2013, and treated with anti-thymocyte globulin for induction or treatment of cellular rejection. Doses were adjusted according to CD3+ T cell or total lymphocyte counts in peripheral blood. Results: A total of 664 paired samples were analyzed. The Spearman's correlation coefficient was 0.416 (p<0.001) for all samples combined; the overall Kappa coefficient was 0.267 (p<0.001). Diagnostic parameters estimated based on total lymphocyte counts were also calculated using the number of CD3+ T cells (gold standard), with a cut off of >20 cells/mm3. Conclusion: Total lymphocyte and CD3+ T cell counts in peripheral blood are not equivalent monitoring strategies in anti-thymocyte globulin therapy. |
publishDate |
2018 |
dc.date.none.fl_str_mv |
2018-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082018000400213 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1679-45082018000400213 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.31744/einstein_journal/2018ao4278 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Instituto Israelita de Ensino e Pesquisa Albert Einstein |
publisher.none.fl_str_mv |
Instituto Israelita de Ensino e Pesquisa Albert Einstein |
dc.source.none.fl_str_mv |
einstein (São Paulo) v.16 n.4 2018 reponame:Einstein (São Paulo) instname:Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) instacron:IIEPAE |
instname_str |
Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) |
instacron_str |
IIEPAE |
institution |
IIEPAE |
reponame_str |
Einstein (São Paulo) |
collection |
Einstein (São Paulo) |
repository.name.fl_str_mv |
Einstein (São Paulo) - Instituto Israelita de Ensino e Pesquisa Albert Einstein (IIEPAE) |
repository.mail.fl_str_mv |
||revista@einstein.br |
_version_ |
1752129909560442880 |