Comparison of two water measurement systems for feedlot beef cattle

Detalhes bibliográficos
Autor(a) principal: Palhares,Júlio Cesar Pascale
Data de Publicação: 2021
Outros Autores: Morelli,Marcela, Novelli,Táisla Inara, Méo Filho,Paulo de, Hisatugu,Matheus Toshio
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Ambiente & Água
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-993X2021000400311
Resumo: Abstract The objective of this study was to compare cattle drinking water consumption collected electronically with that of direct human observation using water metres and to analyse whether an automated system compensates due to its greater precision. The study was conducted in the feedlot of Embrapa Pecuaria Sudeste. The reference unit had four pens: two with electronic drinkers and two with water metres. Experiment 1 utilised 52 Nelore steers and Experiment 2 utilised 44 Canchim steers. Nelore fed a conventional diet, the automated system median daily water intake (DWI) was higher than for animals drinking from the water metre, 17.9 L day-1 and 15.6 L day-1. The reverse was observed for animals fed the co-product diet, the automated system median DWI was 18.9 L day-1 and in the water metre pen was 23.0 L day-1. When the Canchim drank from water metres, the median DWI was lower than with the automated system group, 25.9 L day-1 and 27.8 L day-1, respectively. In Experiment 1, there was a statistical difference between the two sets of equipment for both diets. In Experiment 2, the animals were the same breed, had similar weights and were fed the same diet. There was no statistical difference between the equipment in these conditions. The results indicate that the water meter can have the same performance as high technology at a much lower cost. If a more simplified system for measuring water consumption has the same performance as an automated system, this will justify its use with environmental and economic advantages.
id IPABHI-1_e4fef4406ca8469c56e753b0310129fe
oai_identifier_str oai:scielo:S1980-993X2021000400311
network_acronym_str IPABHI-1
network_name_str Revista Ambiente & Água
repository_id_str
spelling Comparison of two water measurement systems for feedlot beef cattleelectronic drinkersprecision livestock farmingwater meterAbstract The objective of this study was to compare cattle drinking water consumption collected electronically with that of direct human observation using water metres and to analyse whether an automated system compensates due to its greater precision. The study was conducted in the feedlot of Embrapa Pecuaria Sudeste. The reference unit had four pens: two with electronic drinkers and two with water metres. Experiment 1 utilised 52 Nelore steers and Experiment 2 utilised 44 Canchim steers. Nelore fed a conventional diet, the automated system median daily water intake (DWI) was higher than for animals drinking from the water metre, 17.9 L day-1 and 15.6 L day-1. The reverse was observed for animals fed the co-product diet, the automated system median DWI was 18.9 L day-1 and in the water metre pen was 23.0 L day-1. When the Canchim drank from water metres, the median DWI was lower than with the automated system group, 25.9 L day-1 and 27.8 L day-1, respectively. In Experiment 1, there was a statistical difference between the two sets of equipment for both diets. In Experiment 2, the animals were the same breed, had similar weights and were fed the same diet. There was no statistical difference between the equipment in these conditions. The results indicate that the water meter can have the same performance as high technology at a much lower cost. If a more simplified system for measuring water consumption has the same performance as an automated system, this will justify its use with environmental and economic advantages.Instituto de Pesquisas Ambientais em Bacias Hidrográficas2021-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-993X2021000400311Revista Ambiente & Água v.16 n.4 2021reponame:Revista Ambiente & Águainstname:Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHI)instacron:IPABHI10.4136/ambi-agua.2729info:eu-repo/semantics/openAccessPalhares,Júlio Cesar PascaleMorelli,MarcelaNovelli,Táisla InaraMéo Filho,Paulo deHisatugu,Matheus Toshioeng2021-08-18T00:00:00Zoai:scielo:S1980-993X2021000400311Revistahttp://www.ambi-agua.net/PUBhttps://old.scielo.br/oai/scielo-oai.php||ambi.agua@gmail.com1980-993X1980-993Xopendoar:2021-08-18T00:00Revista Ambiente & Água - Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHI)false
dc.title.none.fl_str_mv Comparison of two water measurement systems for feedlot beef cattle
title Comparison of two water measurement systems for feedlot beef cattle
spellingShingle Comparison of two water measurement systems for feedlot beef cattle
Palhares,Júlio Cesar Pascale
electronic drinkers
precision livestock farming
water meter
title_short Comparison of two water measurement systems for feedlot beef cattle
title_full Comparison of two water measurement systems for feedlot beef cattle
title_fullStr Comparison of two water measurement systems for feedlot beef cattle
title_full_unstemmed Comparison of two water measurement systems for feedlot beef cattle
title_sort Comparison of two water measurement systems for feedlot beef cattle
author Palhares,Júlio Cesar Pascale
author_facet Palhares,Júlio Cesar Pascale
Morelli,Marcela
Novelli,Táisla Inara
Méo Filho,Paulo de
Hisatugu,Matheus Toshio
author_role author
author2 Morelli,Marcela
Novelli,Táisla Inara
Méo Filho,Paulo de
Hisatugu,Matheus Toshio
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Palhares,Júlio Cesar Pascale
Morelli,Marcela
Novelli,Táisla Inara
Méo Filho,Paulo de
Hisatugu,Matheus Toshio
dc.subject.por.fl_str_mv electronic drinkers
precision livestock farming
water meter
topic electronic drinkers
precision livestock farming
water meter
description Abstract The objective of this study was to compare cattle drinking water consumption collected electronically with that of direct human observation using water metres and to analyse whether an automated system compensates due to its greater precision. The study was conducted in the feedlot of Embrapa Pecuaria Sudeste. The reference unit had four pens: two with electronic drinkers and two with water metres. Experiment 1 utilised 52 Nelore steers and Experiment 2 utilised 44 Canchim steers. Nelore fed a conventional diet, the automated system median daily water intake (DWI) was higher than for animals drinking from the water metre, 17.9 L day-1 and 15.6 L day-1. The reverse was observed for animals fed the co-product diet, the automated system median DWI was 18.9 L day-1 and in the water metre pen was 23.0 L day-1. When the Canchim drank from water metres, the median DWI was lower than with the automated system group, 25.9 L day-1 and 27.8 L day-1, respectively. In Experiment 1, there was a statistical difference between the two sets of equipment for both diets. In Experiment 2, the animals were the same breed, had similar weights and were fed the same diet. There was no statistical difference between the equipment in these conditions. The results indicate that the water meter can have the same performance as high technology at a much lower cost. If a more simplified system for measuring water consumption has the same performance as an automated system, this will justify its use with environmental and economic advantages.
publishDate 2021
dc.date.none.fl_str_mv 2021-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-993X2021000400311
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1980-993X2021000400311
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.4136/ambi-agua.2729
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Instituto de Pesquisas Ambientais em Bacias Hidrográficas
publisher.none.fl_str_mv Instituto de Pesquisas Ambientais em Bacias Hidrográficas
dc.source.none.fl_str_mv Revista Ambiente & Água v.16 n.4 2021
reponame:Revista Ambiente & Água
instname:Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHI)
instacron:IPABHI
instname_str Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHI)
instacron_str IPABHI
institution IPABHI
reponame_str Revista Ambiente & Água
collection Revista Ambiente & Água
repository.name.fl_str_mv Revista Ambiente & Água - Instituto de Pesquisas Ambientais em Bacias Hidrográficas (IPABHI)
repository.mail.fl_str_mv ||ambi.agua@gmail.com
_version_ 1752129751694180352