Calibration of a clinical beta therapy applicator using the thermoluminescence samples
Autor(a) principal: | |
---|---|
Data de Publicação: | 2020 |
Outros Autores: | , |
Tipo de documento: | Artigo de conferência |
Título da fonte: | Repositório Institucional do IPEN |
Texto Completo: | http://repositorio.ipen.br/handle/123456789/30987 |
Resumo: | In some parts of Brazil, 90Sr/90Y clinical applicators are still used for dermatological and ophthalmic treatments, even with the higher efficiency of linear accelerators because they are of lower cost and easier use. Calibration and periodic recalibration of these applicators to verify the absorbed dose rate is essential to ensure accuracy in clinical treatments. In this work the thermoluminescent response of BeO and ??LiF pellets was evaluated, determining the reproducibility, linearity of response and their dose-response curves. This standard, for this type of calibration, recommends the use of small detectors such as ??LiF. Therefore, the utility of ??LiF and BeO in the calibration of clinical applicators was compared. |
id |
IPEN_362b2bec3f1b82640412d30c8c1fda8b |
---|---|
oai_identifier_str |
oai:repositorio.ipen.br:123456789/30987 |
network_acronym_str |
IPEN |
network_name_str |
Repositório Institucional do IPEN |
repository_id_str |
4510 |
spelling |
2020-03-30T13:47:03Z2020-03-30T13:47:03Z24-27 de novembro, 2019http://repositorio.ipen.br/handle/123456789/309870000-0002-7362-2455In some parts of Brazil, 90Sr/90Y clinical applicators are still used for dermatological and ophthalmic treatments, even with the higher efficiency of linear accelerators because they are of lower cost and easier use. Calibration and periodic recalibration of these applicators to verify the absorbed dose rate is essential to ensure accuracy in clinical treatments. In this work the thermoluminescent response of BeO and ??LiF pellets was evaluated, determining the reproducibility, linearity of response and their dose-response curves. This standard, for this type of calibration, recommends the use of small detectors such as ??LiF. Therefore, the utility of ??LiF and BeO in the calibration of clinical applicators was compared.Submitted by Pedro Silva Filho (pfsilva@ipen.br) on 2020-03-30T13:47:03Z No. of bitstreams: 1 26784.pdf: 783224 bytes, checksum: cb85d8da0cc1534fdb0a6d981db09c9e (MD5)Made available in DSpace on 2020-03-30T13:47:03Z (GMT). No. of bitstreams: 1 26784.pdf: 783224 bytes, checksum: cb85d8da0cc1534fdb0a6d981db09c9e (MD5)Conselho Nacional de Desenvolvimento Cient??fico e Tecnol??gico (CNPq)Coordena????o de Aperfei??oamento de Pessoal de N??vel Superior (CAPES)CNPq: 301335/2016-8CAPES: 554/2018Sociedade Brasileira de Metrologiaberyllium oxideslithium fluoridesbeta particlescalibrationcomparative evaluationsdosimetryradiation sourcestherapythermoluminescenceCalibration of a clinical beta therapy applicator using the thermoluminescence samplesinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/conferenceObjectNRio de Janeiro, RJFlorian??polis, SC145851495600600LITVAC, DANIELCALDAS, LINDA V.E.CONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA EL??TRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MEC??NICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIA????ES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QU??MICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ??PTICA, 3.info:eu-repo/semantics/openAccessreponame:Repositório Institucional do IPENinstname:Instituto de Pesquisas Energéticas e Nucleares (IPEN)instacron:IPEN267842019CALDAS, LINDA V.E.LITVAC, DANIEL20-03Anais149514585preliminary resultsCALDAS, LINDA V.E.:1495:330:NLITVAC, DANIEL:14585:330:SORIGINAL26784.pdf26784.pdfapplication/pdf783224http://repositorio.ipen.br/bitstream/123456789/30987/1/26784.pdfcb85d8da0cc1534fdb0a6d981db09c9eMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://repositorio.ipen.br/bitstream/123456789/30987/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52123456789/309872020-07-16 23:46:09.48oai:repositorio.ipen.br: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Repositório InstitucionalPUBhttp://repositorio.ipen.br/oai/requestbibl@ipen.bropendoar:45102020-07-16T23:46:09Repositório Institucional do IPEN - Instituto de Pesquisas Energéticas e Nucleares (IPEN)false |
dc.title.pt_BR.fl_str_mv |
Calibration of a clinical beta therapy applicator using the thermoluminescence samples |
title |
Calibration of a clinical beta therapy applicator using the thermoluminescence samples |
spellingShingle |
Calibration of a clinical beta therapy applicator using the thermoluminescence samples LITVAC, DANIEL beryllium oxides lithium fluorides beta particles calibration comparative evaluations dosimetry radiation sources therapy thermoluminescence |
title_short |
Calibration of a clinical beta therapy applicator using the thermoluminescence samples |
title_full |
Calibration of a clinical beta therapy applicator using the thermoluminescence samples |
title_fullStr |
Calibration of a clinical beta therapy applicator using the thermoluminescence samples |
title_full_unstemmed |
Calibration of a clinical beta therapy applicator using the thermoluminescence samples |
title_sort |
Calibration of a clinical beta therapy applicator using the thermoluminescence samples |
author |
LITVAC, DANIEL |
author_facet |
LITVAC, DANIEL CALDAS, LINDA V.E. CONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA EL??TRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MEC??NICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIA????ES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QU??MICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ??PTICA, 3. |
author_role |
author |
author2 |
CALDAS, LINDA V.E. CONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA EL??TRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MEC??NICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIA????ES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QU??MICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ??PTICA, 3. |
author2_role |
author author |
dc.contributor.author.fl_str_mv |
LITVAC, DANIEL CALDAS, LINDA V.E. CONGRESSO BRASILEIRO DE METROLOGIA, 10.; CONGRESSO INTERNACIONAL DE METROLOGIA EL??TRICA, 13.; CONGRESSO INTERNACIONAL DE METROLOGIA MEC??NICA, 5.; CONGRESSO BRASILEIRO DE METROLOGIA DAS RADIA????ES IONIZANTES, 6.; WORKSHOP DA REDE DE METROLOGIA QU??MICA DO INMETRO, 4.; CONGRESSO BRASILEIRO DE METROLOGIA ??PTICA, 3. |
dc.subject.por.fl_str_mv |
beryllium oxides lithium fluorides beta particles calibration comparative evaluations dosimetry radiation sources therapy thermoluminescence |
topic |
beryllium oxides lithium fluorides beta particles calibration comparative evaluations dosimetry radiation sources therapy thermoluminescence |
description |
In some parts of Brazil, 90Sr/90Y clinical applicators are still used for dermatological and ophthalmic treatments, even with the higher efficiency of linear accelerators because they are of lower cost and easier use. Calibration and periodic recalibration of these applicators to verify the absorbed dose rate is essential to ensure accuracy in clinical treatments. In this work the thermoluminescent response of BeO and ??LiF pellets was evaluated, determining the reproducibility, linearity of response and their dose-response curves. This standard, for this type of calibration, recommends the use of small detectors such as ??LiF. Therefore, the utility of ??LiF and BeO in the calibration of clinical applicators was compared. |
publishDate |
2020 |
dc.date.evento.pt_BR.fl_str_mv |
24-27 de novembro, 2019 |
dc.date.accessioned.fl_str_mv |
2020-03-30T13:47:03Z |
dc.date.available.fl_str_mv |
2020-03-30T13:47:03Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/conferenceObject |
format |
conferenceObject |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://repositorio.ipen.br/handle/123456789/30987 |
dc.identifier.orcid.pt_BR.fl_str_mv |
0000-0002-7362-2455 |
url |
http://repositorio.ipen.br/handle/123456789/30987 |
identifier_str_mv |
0000-0002-7362-2455 |
dc.relation.authority.fl_str_mv |
14585 1495 |
dc.relation.confidence.fl_str_mv |
600 600 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.coverage.pt_BR.fl_str_mv |
N |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Metrologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Metrologia |
dc.source.none.fl_str_mv |
reponame:Repositório Institucional do IPEN instname:Instituto de Pesquisas Energéticas e Nucleares (IPEN) instacron:IPEN |
instname_str |
Instituto de Pesquisas Energéticas e Nucleares (IPEN) |
instacron_str |
IPEN |
institution |
IPEN |
reponame_str |
Repositório Institucional do IPEN |
collection |
Repositório Institucional do IPEN |
bitstream.url.fl_str_mv |
http://repositorio.ipen.br/bitstream/123456789/30987/1/26784.pdf http://repositorio.ipen.br/bitstream/123456789/30987/2/license.txt |
bitstream.checksum.fl_str_mv |
cb85d8da0cc1534fdb0a6d981db09c9e 8a4605be74aa9ea9d79846c1fba20a33 |
bitstream.checksumAlgorithm.fl_str_mv |
MD5 MD5 |
repository.name.fl_str_mv |
Repositório Institucional do IPEN - Instituto de Pesquisas Energéticas e Nucleares (IPEN) |
repository.mail.fl_str_mv |
bibl@ipen.br |
_version_ |
1767254251468226560 |