Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments

Bibliographic Details
Main Author: Faot, Fernanda
Publication Date: 2009
Other Authors: Silva, Wander José da, R. Garcia, Renata Cunha Matheus, Del Bel Cury, Altair Antoninha
Format: Article
Language: eng
Source: Revista odonto ciência (Online)
Download full: https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408
Summary: Purpose: Titanium alloys are commonly used for prosthetic abutments fabrication, but these alloys present high cost and difficult handling. Alternative Ni-Cr alloys with Mo and Ti combination have been proposed. This study compared the alloys Ti-6Al-4V and Ni-Cr-Ti-Mo by analyzing their surface properties such as hardness, morphology and microstructural characterization. Methods: Five discs (5 x 2 mm) of commercially Ti-6Al-4V and Ni-Cr-Ti-Mo alloys were used to evaluate Vickers hardness by hardness micro indentation test. The same specimens were analyzed by scanning electron microscopy (SEM) regarding surface morphology and subjected to a metallographic analysis of the microstructure by optical microscopy. Data on surface hardness were analyzed using one-way ANOVA followed by Tukey test (α = 0.05). Results: The Ni-Cr-Mo-Ti alloy showed significantly higher Vickers hardness (kg/mm2) values (452.2 ± 3.9) than the Ti-6Al-4V alloy (375.7 ± 15.2). The surface morphology evaluated by SEM revealed differences between the alloys. Metallographic analyses, for both alloys, showed a two-phase equilibrium microstructure, with the presence of e α + β phase for Ti-6Al-4V; and gamma (γ) primary phase and gamma-prime (γ’) as a second phase for Ni-Cr-Mo-Ti. Conclusion: It can be concluded that both alloys present the requirements to be used in prosthetic abutments.
id PUC_RS-22_b867e30d8a7eba469d02f33a2b14e3c6
oai_identifier_str oai:ojs.revistaseletronicas.pucrs.br:article/5408
network_acronym_str PUC_RS-22
network_name_str Revista odonto ciência (Online)
repository_id_str
spelling Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutmentsCaracterização microestrutural das ligas Ni-Cr-Mo-Ti e Ti-6Al-4V utilizadas para pilares de prótesesTi-6Al-4VNi-Cr-Mo-Tidental alloymicrostructurehardnessabutmentmetal alloysPurpose: Titanium alloys are commonly used for prosthetic abutments fabrication, but these alloys present high cost and difficult handling. Alternative Ni-Cr alloys with Mo and Ti combination have been proposed. This study compared the alloys Ti-6Al-4V and Ni-Cr-Ti-Mo by analyzing their surface properties such as hardness, morphology and microstructural characterization. Methods: Five discs (5 x 2 mm) of commercially Ti-6Al-4V and Ni-Cr-Ti-Mo alloys were used to evaluate Vickers hardness by hardness micro indentation test. The same specimens were analyzed by scanning electron microscopy (SEM) regarding surface morphology and subjected to a metallographic analysis of the microstructure by optical microscopy. Data on surface hardness were analyzed using one-way ANOVA followed by Tukey test (α = 0.05). Results: The Ni-Cr-Mo-Ti alloy showed significantly higher Vickers hardness (kg/mm2) values (452.2 ± 3.9) than the Ti-6Al-4V alloy (375.7 ± 15.2). The surface morphology evaluated by SEM revealed differences between the alloys. Metallographic analyses, for both alloys, showed a two-phase equilibrium microstructure, with the presence of e α + β phase for Ti-6Al-4V; and gamma (γ) primary phase and gamma-prime (γ’) as a second phase for Ni-Cr-Mo-Ti. Conclusion: It can be concluded that both alloys present the requirements to be used in prosthetic abutments.Objetivo: As ligas de titânio são comumente usadas para a fabricação de componentes protéticos, entretanto apresentam alto custo e dificuldade de manuseio laboratorial. Ligas alternativas a base de Ni-Cr combinadas com Mo e Ti também tem sido propostas com o mesmo objeto. Este estudo comparou as ligas Ti-6Al-4V e Ni-Cr-Ti-Mo pela análise de suas propriedades de superfície como dureza, morfologia e caracterização da microestrutura. Metodologia: Cinco discos (5 × 2 mm) das ligas Ti-6Al-4V e Ni-Cr-Ti-Mo foram utilizados para a avaliação da dureza Vickers, análise de morfologia de superfície por meio da microscopia eletrônica de varredura (MEV) e análise da microestrutura pela análise metalográfica. Os dados da dureza de superfície foram analisados pela Análise de Variância a um nível seguida do teste de Tukey (α = 0,05). Resultados: A liga Ni-Cr-Mo-Ti apresentou os maiores valores de dureza Vickers (kg/mm2) (452,2 ± 3,9) comparada a liga Ti-6Al-4V (375,7 ± 15,2) A morfologia de superfície avaliada por MEV revelou características distintas entre as ligas. A análise metalográfica para ambas as ligas mostrou uma microestrutura com equilíbrio de duas fases, com a presença de fase α + β para Ti-6Al-4V; e fase gamma primária (γ) e fase gamma-prime (γ') como secundária para Ni-Cr-Mo-Ti. Conclusão: Ambas as ligas podem ser utilizadas para fabricação de pilares protéticos.EDIPUCRS - Editora Universitária da PUCRS2009-08-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer-reviewed Articledescriptive; laboratoryapplication/pdfhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408Revista Odonto Ciência; Vol. 24 No. 4 (2009); 401 - 405Revista Odonto Ciência; v. 24 n. 4 (2009); 401 - 4051980-65230102-9460reponame:Revista odonto ciência (Online)instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)instacron:PUC_RSenghttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408/4782Faot, FernandaSilva, Wander José daR. Garcia, Renata Cunha MatheusDel Bel Cury, Altair Antoninhainfo:eu-repo/semantics/openAccess2013-11-11T12:57:32Zoai:ojs.revistaseletronicas.pucrs.br:article/5408Revistahttps://revistaseletronicas.pucrs.br/ojs/index.php/foPRIhttps://revistaseletronicas.pucrs.br/ojs/index.php/fo/oai||odontociencia@pucrs.br1980-65230102-9460opendoar:2013-11-11T12:57:32Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)false
dc.title.none.fl_str_mv Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments
Caracterização microestrutural das ligas Ni-Cr-Mo-Ti e Ti-6Al-4V utilizadas para pilares de próteses
title Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments
spellingShingle Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments
Faot, Fernanda
Ti-6Al-4V
Ni-Cr-Mo-Ti
dental alloy
microstructure
hardness
abutment
metal alloys
title_short Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments
title_full Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments
title_fullStr Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments
title_full_unstemmed Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments
title_sort Microstructural characterization of Ni-Cr-Mo-Ti and Ti-6Al-4V alloys used in prosthetic abutments
author Faot, Fernanda
author_facet Faot, Fernanda
Silva, Wander José da
R. Garcia, Renata Cunha Matheus
Del Bel Cury, Altair Antoninha
author_role author
author2 Silva, Wander José da
R. Garcia, Renata Cunha Matheus
Del Bel Cury, Altair Antoninha
author2_role author
author
author
dc.contributor.author.fl_str_mv Faot, Fernanda
Silva, Wander José da
R. Garcia, Renata Cunha Matheus
Del Bel Cury, Altair Antoninha
dc.subject.por.fl_str_mv Ti-6Al-4V
Ni-Cr-Mo-Ti
dental alloy
microstructure
hardness
abutment
metal alloys
topic Ti-6Al-4V
Ni-Cr-Mo-Ti
dental alloy
microstructure
hardness
abutment
metal alloys
description Purpose: Titanium alloys are commonly used for prosthetic abutments fabrication, but these alloys present high cost and difficult handling. Alternative Ni-Cr alloys with Mo and Ti combination have been proposed. This study compared the alloys Ti-6Al-4V and Ni-Cr-Ti-Mo by analyzing their surface properties such as hardness, morphology and microstructural characterization. Methods: Five discs (5 x 2 mm) of commercially Ti-6Al-4V and Ni-Cr-Ti-Mo alloys were used to evaluate Vickers hardness by hardness micro indentation test. The same specimens were analyzed by scanning electron microscopy (SEM) regarding surface morphology and subjected to a metallographic analysis of the microstructure by optical microscopy. Data on surface hardness were analyzed using one-way ANOVA followed by Tukey test (α = 0.05). Results: The Ni-Cr-Mo-Ti alloy showed significantly higher Vickers hardness (kg/mm2) values (452.2 ± 3.9) than the Ti-6Al-4V alloy (375.7 ± 15.2). The surface morphology evaluated by SEM revealed differences between the alloys. Metallographic analyses, for both alloys, showed a two-phase equilibrium microstructure, with the presence of e α + β phase for Ti-6Al-4V; and gamma (γ) primary phase and gamma-prime (γ’) as a second phase for Ni-Cr-Mo-Ti. Conclusion: It can be concluded that both alloys present the requirements to be used in prosthetic abutments.
publishDate 2009
dc.date.none.fl_str_mv 2009-08-10
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
Peer-reviewed Article
descriptive; laboratory
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408
url https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://revistaseletronicas.pucrs.br/ojs/index.php/fo/article/view/5408/4782
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
publisher.none.fl_str_mv EDIPUCRS - Editora Universitária da PUCRS
dc.source.none.fl_str_mv Revista Odonto Ciência; Vol. 24 No. 4 (2009); 401 - 405
Revista Odonto Ciência; v. 24 n. 4 (2009); 401 - 405
1980-6523
0102-9460
reponame:Revista odonto ciência (Online)
instname:Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron:PUC_RS
instname_str Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
instacron_str PUC_RS
institution PUC_RS
reponame_str Revista odonto ciência (Online)
collection Revista odonto ciência (Online)
repository.name.fl_str_mv Revista odonto ciência (Online) - Pontifícia Universidade Católica do Rio Grande do Sul (PUCRS)
repository.mail.fl_str_mv ||odontociencia@pucrs.br
_version_ 1754820874921312256