Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filter

Detalhes bibliográficos
Autor(a) principal: Albuquerque, Antonio
Data de Publicação: 2012
Outros Autores: Makinia, Jacek, Pagilla, Krishna
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.6/1475
Resumo: A submerged biological aerated filter (BAF) partially aerated was used to study the removal of low concentrations of ammonia nitrogen (0.3 g N/m3 to 30.5 g N/m3) typically found in nutrient enriched river and lake waters, and treated effluents. Four series of experiments were performed with a synthetic wastewater at ammonia loading rates between 6 g N/m3 d and 903 g N/m3 d and C/N ratios from 2 to 20. The results showed that ammonia removal rates reached higher values (172 g N/m3 d to 564 g N/m3 d) for C/N = 2 and lower values (13.6 g N/m3 d to 34.6 g N/m3 d) for C/N = 20. Between 50% and 70% of the ammonia was removed in the upper section of the BAF, where the dissolved oxygen (DO) concentration was over 2.1 g O2/m3 and the biofilm depth ranged from 0.4 to 0.6 mm. At the bottom section of the reactor, simultaneous removal of ammonia and nitrate was observed at the DO concentrations in the range 0.4 g O2/m3 to 0.8 g O2/m3. There was no removal of ammonia nitrogen for loads below 15 g N/m3.d. The results indicate that the removal of nitrogen in partially aerated BAF may not only be explained by the conventional mechanisms of nitrification/denitrification.
id RCAP_129fc1f11a8d827602e58b20f896e352
oai_identifier_str oai:ubibliorum.ubi.pt:10400.6/1475
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str
spelling Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filterBiological aerated filterDenitrificationNitrogen removalNitrificationPartial aerationBAFResidual removalNutrient removalA submerged biological aerated filter (BAF) partially aerated was used to study the removal of low concentrations of ammonia nitrogen (0.3 g N/m3 to 30.5 g N/m3) typically found in nutrient enriched river and lake waters, and treated effluents. Four series of experiments were performed with a synthetic wastewater at ammonia loading rates between 6 g N/m3 d and 903 g N/m3 d and C/N ratios from 2 to 20. The results showed that ammonia removal rates reached higher values (172 g N/m3 d to 564 g N/m3 d) for C/N = 2 and lower values (13.6 g N/m3 d to 34.6 g N/m3 d) for C/N = 20. Between 50% and 70% of the ammonia was removed in the upper section of the BAF, where the dissolved oxygen (DO) concentration was over 2.1 g O2/m3 and the biofilm depth ranged from 0.4 to 0.6 mm. At the bottom section of the reactor, simultaneous removal of ammonia and nitrate was observed at the DO concentrations in the range 0.4 g O2/m3 to 0.8 g O2/m3. There was no removal of ammonia nitrogen for loads below 15 g N/m3.d. The results indicate that the removal of nitrogen in partially aerated BAF may not only be explained by the conventional mechanisms of nitrification/denitrification.ElsevieruBibliorumAlbuquerque, AntonioMakinia, JacekPagilla, Krishna2013-11-09T23:09:12Z20122012-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.6/1475eng0925-8574info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-01-16T11:38:39ZPortal AgregadorONG
dc.title.none.fl_str_mv Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filter
title Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filter
spellingShingle Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filter
Albuquerque, Antonio
Biological aerated filter
Denitrification
Nitrogen removal
Nitrification
Partial aeration
BAF
Residual removal
Nutrient removal
title_short Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filter
title_full Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filter
title_fullStr Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filter
title_full_unstemmed Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filter
title_sort Impact of aeration conditions on the removal of low concentrations of nitrogen in a tertiary partially aerated biological filter
author Albuquerque, Antonio
author_facet Albuquerque, Antonio
Makinia, Jacek
Pagilla, Krishna
author_role author
author2 Makinia, Jacek
Pagilla, Krishna
author2_role author
author
dc.contributor.none.fl_str_mv uBibliorum
dc.contributor.author.fl_str_mv Albuquerque, Antonio
Makinia, Jacek
Pagilla, Krishna
dc.subject.por.fl_str_mv Biological aerated filter
Denitrification
Nitrogen removal
Nitrification
Partial aeration
BAF
Residual removal
Nutrient removal
topic Biological aerated filter
Denitrification
Nitrogen removal
Nitrification
Partial aeration
BAF
Residual removal
Nutrient removal
description A submerged biological aerated filter (BAF) partially aerated was used to study the removal of low concentrations of ammonia nitrogen (0.3 g N/m3 to 30.5 g N/m3) typically found in nutrient enriched river and lake waters, and treated effluents. Four series of experiments were performed with a synthetic wastewater at ammonia loading rates between 6 g N/m3 d and 903 g N/m3 d and C/N ratios from 2 to 20. The results showed that ammonia removal rates reached higher values (172 g N/m3 d to 564 g N/m3 d) for C/N = 2 and lower values (13.6 g N/m3 d to 34.6 g N/m3 d) for C/N = 20. Between 50% and 70% of the ammonia was removed in the upper section of the BAF, where the dissolved oxygen (DO) concentration was over 2.1 g O2/m3 and the biofilm depth ranged from 0.4 to 0.6 mm. At the bottom section of the reactor, simultaneous removal of ammonia and nitrate was observed at the DO concentrations in the range 0.4 g O2/m3 to 0.8 g O2/m3. There was no removal of ammonia nitrogen for loads below 15 g N/m3.d. The results indicate that the removal of nitrogen in partially aerated BAF may not only be explained by the conventional mechanisms of nitrification/denitrification.
publishDate 2012
dc.date.none.fl_str_mv 2012
2012-01-01T00:00:00Z
2013-11-09T23:09:12Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.6/1475
url http://hdl.handle.net/10400.6/1475
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 0925-8574
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv