Assessment of the density loss in anobiid infested pine using x-ray micro-computed tomography

Detalhes bibliográficos
Autor(a) principal: Parracha, João
Data de Publicação: 2021
Outros Autores: Pereira, Manuel Francisco Costa, Maurício, António, Faria, Paulina, Lima, Daniel F., Tenório, Marina, Nunes, Lina
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10362/119392
Resumo: The authors acknowledge the support given by Portuguese Foundation for Science and Technology (FCT) within research projects: PTDC/EPH-PAT/4684/2014 (DB-HERITAGE), PTDC/ECM-EST/1072/2014 (Pro-Timber), Pest-OE/CTE/UI4028/2011 (CERENA) and UIDB/04625/2020 (CERIS).
id RCAP_2e3d4efa117e99f6da3b771fb3fc10d8
oai_identifier_str oai:run.unl.pt:10362/119392
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str
spelling Assessment of the density loss in anobiid infested pine using x-ray micro-computed tomographyAnobiid infestationDamage assessmentResidual apparent densityThree-dimensional reconstructionWoodArchitectureCivil and Structural EngineeringBuilding and ConstructionThe authors acknowledge the support given by Portuguese Foundation for Science and Technology (FCT) within research projects: PTDC/EPH-PAT/4684/2014 (DB-HERITAGE), PTDC/ECM-EST/1072/2014 (Pro-Timber), Pest-OE/CTE/UI4028/2011 (CERENA) and UIDB/04625/2020 (CERIS).The present study aims at evaluating the impact of anobiid damage on pine timber elements. Anobiid attack produces a diffuse damage of the elements with a set of tunnels in random directions and sizes, thus confusing quantification. Therefore, a method was developed based on X-ray micro-computed tomography (µ-XCT) to obtain, for naturally infested timber samples, an empirical correlation between lost material percentage (consumed by beetles) and timber apparent density (original, before degradation—OTD and residual, after degradation—RTD). The quantified density loss can then be used in further assessment of the structure. The results of the tests performed showed high correlation between original apparent density and lost material percentage (r2 = 0.60) and between residual apparent density and lost material percentage (r2 = 0.83), which confirms µ-XCT as a valuable tool to the required quantification. The loss of density results can be further applied on the definition of an assessment method for the evaluation of the residual strength of anobiids infested timber, thus contributing to reducing unnecessary replacement. The optimized procedure of the µ-XCT study for infested Maritime pine (Pinus pinaster) is presented and discussed in this article.DEC - Departamento de Engenharia CivilRUNParracha, JoãoPereira, Manuel Francisco CostaMaurício, AntónioFaria, PaulinaLima, Daniel F.Tenório, MarinaNunes, Lina2021-06-16T22:19:54Z2021-04-172021-04-17T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article13application/pdfhttp://hdl.handle.net/10362/119392eng2075-5309PURE: 29761029https://doi.org/10.3390/buildings11040173info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-10T16:00:58ZPortal AgregadorONG
dc.title.none.fl_str_mv Assessment of the density loss in anobiid infested pine using x-ray micro-computed tomography
title Assessment of the density loss in anobiid infested pine using x-ray micro-computed tomography
spellingShingle Assessment of the density loss in anobiid infested pine using x-ray micro-computed tomography
Parracha, João
Anobiid infestation
Damage assessment
Residual apparent density
Three-dimensional reconstruction
Wood
Architecture
Civil and Structural Engineering
Building and Construction
title_short Assessment of the density loss in anobiid infested pine using x-ray micro-computed tomography
title_full Assessment of the density loss in anobiid infested pine using x-ray micro-computed tomography
title_fullStr Assessment of the density loss in anobiid infested pine using x-ray micro-computed tomography
title_full_unstemmed Assessment of the density loss in anobiid infested pine using x-ray micro-computed tomography
title_sort Assessment of the density loss in anobiid infested pine using x-ray micro-computed tomography
author Parracha, João
author_facet Parracha, João
Pereira, Manuel Francisco Costa
Maurício, António
Faria, Paulina
Lima, Daniel F.
Tenório, Marina
Nunes, Lina
author_role author
author2 Pereira, Manuel Francisco Costa
Maurício, António
Faria, Paulina
Lima, Daniel F.
Tenório, Marina
Nunes, Lina
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv DEC - Departamento de Engenharia Civil
RUN
dc.contributor.author.fl_str_mv Parracha, João
Pereira, Manuel Francisco Costa
Maurício, António
Faria, Paulina
Lima, Daniel F.
Tenório, Marina
Nunes, Lina
dc.subject.por.fl_str_mv Anobiid infestation
Damage assessment
Residual apparent density
Three-dimensional reconstruction
Wood
Architecture
Civil and Structural Engineering
Building and Construction
topic Anobiid infestation
Damage assessment
Residual apparent density
Three-dimensional reconstruction
Wood
Architecture
Civil and Structural Engineering
Building and Construction
description The authors acknowledge the support given by Portuguese Foundation for Science and Technology (FCT) within research projects: PTDC/EPH-PAT/4684/2014 (DB-HERITAGE), PTDC/ECM-EST/1072/2014 (Pro-Timber), Pest-OE/CTE/UI4028/2011 (CERENA) and UIDB/04625/2020 (CERIS).
publishDate 2021
dc.date.none.fl_str_mv 2021-06-16T22:19:54Z
2021-04-17
2021-04-17T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10362/119392
url http://hdl.handle.net/10362/119392
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2075-5309
PURE: 29761029
https://doi.org/10.3390/buildings11040173
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 13
application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1777303037839147008