Physicochemical properties and filling capacity of an experimental iodoform-based paste in primary teeth

Detalhes bibliográficos
Autor(a) principal: Marques, Renata Pereira de Samuel
Data de Publicação: 2020
Outros Autores: Moura-Netto, Cacio, Oliveira, Natalia Matsuda de, Bresolin, Carmela Rampazzo, Mello-Moura, Anna Carolina Volpi, Mendes, Fausto Medeiros, Novaes, Tatiane Fernandes
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.14/32424
Resumo: In this study, we evaluated the physicochemical properties (PCP; radiopacity, flow, pH, and solubility) and the quality of root canal filling provided by an experimental industrialized paste (EP), with the same active ingredients as those of the Guedes Pinto paste, compared with the Vitapex® paste. PCP were analyzed according to the ANSI/ADA laboratory testing methods for endodontic filling and sealing materials. To analyze filling capacity, 120 artificial primary teeth (60 maxillary incisors [MIs] and 60 mandibulary molars [MMs]) were endodontically treated. The teeth were divided into eight groups based on the dental group (MIs or MMs), filling material (Vitapex® or EP), and insertion method (syringe or lentulo). The Image J® software was used to analyze the initial an final digital radiographies of each tooth, measuring and comparing root canal and void areas. The percentage of filling failure areas was obtained. Data were submitted to ANOVA and Tukey test of mean comparison. Regarding PCP, both pastes presented results according the ANSI/ADA standards. Flow capacity: Vitapex: 19.6 mm, EP: 25 mm (p < 0.01); radiopacity: Vitapex: 4.47 mmAl, EP: 6.06 mmAl (p < 0.01); pH after 28 days: Vitapex: 7.79, EP: 8.19 (p = 0.12); and solubility after 28 days: Vitapex: 2.68%, EP: 2.89% (p > 0.05). Regarding filling capacity analysis, EP demonstrated 12.5% of failure against 31.5% of Vitapex (p < 0.01). Compared to Vitapex, EP presented statistically significantly better results in flow, radiopacity, pH, and filling capacity. Molars presented more filling failures than incisors. The insertion method using a syringe and a thin tip was significantly better than that using Lentulo spiral carriers.
id RCAP_3361226bbec4aabd1eb6e35cf243b4db
oai_identifier_str oai:repositorio.ucp.pt:10400.14/32424
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Physicochemical properties and filling capacity of an experimental iodoform-based paste in primary teethDeciduousEndodonticsRoot canal obturationToothIn this study, we evaluated the physicochemical properties (PCP; radiopacity, flow, pH, and solubility) and the quality of root canal filling provided by an experimental industrialized paste (EP), with the same active ingredients as those of the Guedes Pinto paste, compared with the Vitapex® paste. PCP were analyzed according to the ANSI/ADA laboratory testing methods for endodontic filling and sealing materials. To analyze filling capacity, 120 artificial primary teeth (60 maxillary incisors [MIs] and 60 mandibulary molars [MMs]) were endodontically treated. The teeth were divided into eight groups based on the dental group (MIs or MMs), filling material (Vitapex® or EP), and insertion method (syringe or lentulo). The Image J® software was used to analyze the initial an final digital radiographies of each tooth, measuring and comparing root canal and void areas. The percentage of filling failure areas was obtained. Data were submitted to ANOVA and Tukey test of mean comparison. Regarding PCP, both pastes presented results according the ANSI/ADA standards. Flow capacity: Vitapex: 19.6 mm, EP: 25 mm (p < 0.01); radiopacity: Vitapex: 4.47 mmAl, EP: 6.06 mmAl (p < 0.01); pH after 28 days: Vitapex: 7.79, EP: 8.19 (p = 0.12); and solubility after 28 days: Vitapex: 2.68%, EP: 2.89% (p > 0.05). Regarding filling capacity analysis, EP demonstrated 12.5% of failure against 31.5% of Vitapex (p < 0.01). Compared to Vitapex, EP presented statistically significantly better results in flow, radiopacity, pH, and filling capacity. Molars presented more filling failures than incisors. The insertion method using a syringe and a thin tip was significantly better than that using Lentulo spiral carriers.Veritati - Repositório Institucional da Universidade Católica PortuguesaMarques, Renata Pereira de SamuelMoura-Netto, CacioOliveira, Natalia Matsuda deBresolin, Carmela RampazzoMello-Moura, Anna Carolina VolpiMendes, Fausto MedeirosNovaes, Tatiane Fernandes2021-03-31T14:31:05Z20202020-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.14/32424eng1517-749110.1590/1807-3107bor-2020.vol34.00898508940761232785478000651511900001info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-12-05T01:37:19Zoai:repositorio.ucp.pt:10400.14/32424Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:26:10.960921Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Physicochemical properties and filling capacity of an experimental iodoform-based paste in primary teeth
title Physicochemical properties and filling capacity of an experimental iodoform-based paste in primary teeth
spellingShingle Physicochemical properties and filling capacity of an experimental iodoform-based paste in primary teeth
Marques, Renata Pereira de Samuel
Deciduous
Endodontics
Root canal obturation
Tooth
title_short Physicochemical properties and filling capacity of an experimental iodoform-based paste in primary teeth
title_full Physicochemical properties and filling capacity of an experimental iodoform-based paste in primary teeth
title_fullStr Physicochemical properties and filling capacity of an experimental iodoform-based paste in primary teeth
title_full_unstemmed Physicochemical properties and filling capacity of an experimental iodoform-based paste in primary teeth
title_sort Physicochemical properties and filling capacity of an experimental iodoform-based paste in primary teeth
author Marques, Renata Pereira de Samuel
author_facet Marques, Renata Pereira de Samuel
Moura-Netto, Cacio
Oliveira, Natalia Matsuda de
Bresolin, Carmela Rampazzo
Mello-Moura, Anna Carolina Volpi
Mendes, Fausto Medeiros
Novaes, Tatiane Fernandes
author_role author
author2 Moura-Netto, Cacio
Oliveira, Natalia Matsuda de
Bresolin, Carmela Rampazzo
Mello-Moura, Anna Carolina Volpi
Mendes, Fausto Medeiros
Novaes, Tatiane Fernandes
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv Veritati - Repositório Institucional da Universidade Católica Portuguesa
dc.contributor.author.fl_str_mv Marques, Renata Pereira de Samuel
Moura-Netto, Cacio
Oliveira, Natalia Matsuda de
Bresolin, Carmela Rampazzo
Mello-Moura, Anna Carolina Volpi
Mendes, Fausto Medeiros
Novaes, Tatiane Fernandes
dc.subject.por.fl_str_mv Deciduous
Endodontics
Root canal obturation
Tooth
topic Deciduous
Endodontics
Root canal obturation
Tooth
description In this study, we evaluated the physicochemical properties (PCP; radiopacity, flow, pH, and solubility) and the quality of root canal filling provided by an experimental industrialized paste (EP), with the same active ingredients as those of the Guedes Pinto paste, compared with the Vitapex® paste. PCP were analyzed according to the ANSI/ADA laboratory testing methods for endodontic filling and sealing materials. To analyze filling capacity, 120 artificial primary teeth (60 maxillary incisors [MIs] and 60 mandibulary molars [MMs]) were endodontically treated. The teeth were divided into eight groups based on the dental group (MIs or MMs), filling material (Vitapex® or EP), and insertion method (syringe or lentulo). The Image J® software was used to analyze the initial an final digital radiographies of each tooth, measuring and comparing root canal and void areas. The percentage of filling failure areas was obtained. Data were submitted to ANOVA and Tukey test of mean comparison. Regarding PCP, both pastes presented results according the ANSI/ADA standards. Flow capacity: Vitapex: 19.6 mm, EP: 25 mm (p < 0.01); radiopacity: Vitapex: 4.47 mmAl, EP: 6.06 mmAl (p < 0.01); pH after 28 days: Vitapex: 7.79, EP: 8.19 (p = 0.12); and solubility after 28 days: Vitapex: 2.68%, EP: 2.89% (p > 0.05). Regarding filling capacity analysis, EP demonstrated 12.5% of failure against 31.5% of Vitapex (p < 0.01). Compared to Vitapex, EP presented statistically significantly better results in flow, radiopacity, pH, and filling capacity. Molars presented more filling failures than incisors. The insertion method using a syringe and a thin tip was significantly better than that using Lentulo spiral carriers.
publishDate 2020
dc.date.none.fl_str_mv 2020
2020-01-01T00:00:00Z
2021-03-31T14:31:05Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.14/32424
url http://hdl.handle.net/10400.14/32424
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1517-7491
10.1590/1807-3107bor-2020.vol34.0089
85089407612
32785478
000651511900001
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131977731801088