Efficacy of a gas permeable contact lens to induce peripheral myopic defocus

Detalhes bibliográficos
Autor(a) principal: Pauné, Jaume
Data de Publicação: 2015
Outros Autores: Queirós, A., Ferreira, Daniela Lopes, Ribeiro, Miguel António Faria, Quevedo, L., González-Méijome, José Manuel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/39500
Resumo: Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients. Methods. Fifty-two right eyes of 52 myopic patients (mean [TSD] age, 21 [T2] years) with spherical refractive errors ranging from j0.75 to j8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields. Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p G 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding j1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error. Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baselin spherical equivalent refractive error.
id RCAP_519dd266425fdc7fb9101f1cfa35b18d
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/39500
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str
spelling Efficacy of a gas permeable contact lens to induce peripheral myopic defocusMyopia progressionGas permeable contact lensPeripheral refractionScience & TechnologyPurpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients. Methods. Fifty-two right eyes of 52 myopic patients (mean [TSD] age, 21 [T2] years) with spherical refractive errors ranging from j0.75 to j8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields. Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p G 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding j1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error. Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baselin spherical equivalent refractive error.Jaume Paune´ has proprietary and financial interests in the manufacturing and distribution of lenses evaluated in this study. The remaining authors declare that they do not have any proprietary or financial interest in any of the materials mentioned in this article. This work was partially funded by Fundação para Ciência e Tecnologia, Portugal, Projects: PTDC/SAU-BEB/ 098392/2008 and PTDC/SAU-BEB/098391/2008American Academy of Optometry (AAOPT)Universidade do MinhoPauné, JaumeQueirós, A.Ferreira, Daniela LopesRibeiro, Miguel António FariaQuevedo, L.González-Méijome, José Manuel20152015-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/39500engPauné, Jaume; Queiros, Antonio; Lopes-Ferreira, Daniela; Faria-Ribeiro, Miguel; Quevedo, Lluisa; Gonzalez-Meijome, Jose Manuel. Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus, Optometry and Vision Science, 92, 5, 596-603, 2015.1040-548810.1097/OPX.000000000000058225875679info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:41:50ZPortal AgregadorONG
dc.title.none.fl_str_mv Efficacy of a gas permeable contact lens to induce peripheral myopic defocus
title Efficacy of a gas permeable contact lens to induce peripheral myopic defocus
spellingShingle Efficacy of a gas permeable contact lens to induce peripheral myopic defocus
Pauné, Jaume
Myopia progression
Gas permeable contact lens
Peripheral refraction
Science & Technology
title_short Efficacy of a gas permeable contact lens to induce peripheral myopic defocus
title_full Efficacy of a gas permeable contact lens to induce peripheral myopic defocus
title_fullStr Efficacy of a gas permeable contact lens to induce peripheral myopic defocus
title_full_unstemmed Efficacy of a gas permeable contact lens to induce peripheral myopic defocus
title_sort Efficacy of a gas permeable contact lens to induce peripheral myopic defocus
author Pauné, Jaume
author_facet Pauné, Jaume
Queirós, A.
Ferreira, Daniela Lopes
Ribeiro, Miguel António Faria
Quevedo, L.
González-Méijome, José Manuel
author_role author
author2 Queirós, A.
Ferreira, Daniela Lopes
Ribeiro, Miguel António Faria
Quevedo, L.
González-Méijome, José Manuel
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Pauné, Jaume
Queirós, A.
Ferreira, Daniela Lopes
Ribeiro, Miguel António Faria
Quevedo, L.
González-Méijome, José Manuel
dc.subject.por.fl_str_mv Myopia progression
Gas permeable contact lens
Peripheral refraction
Science & Technology
topic Myopia progression
Gas permeable contact lens
Peripheral refraction
Science & Technology
description Purpose. The purpose of this work was to evaluate the potential of a novel custom-designed rigid gas permeable (RGP) contact lens to modify the relative peripheral refractive error in a sample of myopic patients. Methods. Fifty-two right eyes of 52 myopic patients (mean [TSD] age, 21 [T2] years) with spherical refractive errors ranging from j0.75 to j8.00 diopters (D) and refractive astigmatism of 1.00 D or less were fitted with a novel experimental RGP (ExpRGP) lens designed to create myopic defocus in the peripheral retina. A standard RGP (StdRGP) lens was used as a control in the same eye. The relative peripheral refractive error was measured without the lens and with each of two lenses (StdRGP and ExpRGP) using an open-field autorefractometer from 30 degrees nasal to 30 degrees temporal, in 5-degree steps. The effectiveness of the lens design was evaluated as the amount of relative peripheral refractive error difference induced by the ExpRGP compared with no lens and with StdRGP conditions at 30 degrees in the nasal and temporal (averaged) peripheral visual fields. Results. Experimental RGP lens induced a significant change in relative peripheral refractive error compared with the nolens condition (baseline), beyond the 10 degrees of eccentricity to the nasal and temporal side of the visual field (p G 0.05). The maximum effect was achieved at 30 degrees. Wearing the ExpRGP lens, 60% of the eyes had peripheral myopia exceeding j1.00 D, whereas none of the eyes presented with this feature at baseline. There was no significant correlation (r = 0.04; p = 0.756) between the degree of myopia induced at 30 degrees of eccentricity of the visual field with the ExpRGP lens and the baseline refractive error. Conclusions. Custom-designed RGP contact lenses can generate a significant degree of relative peripheral myopia in myopic patients regardless of their baselin spherical equivalent refractive error.
publishDate 2015
dc.date.none.fl_str_mv 2015
2015-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/39500
url http://hdl.handle.net/1822/39500
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Pauné, Jaume; Queiros, Antonio; Lopes-Ferreira, Daniela; Faria-Ribeiro, Miguel; Quevedo, Lluisa; Gonzalez-Meijome, Jose Manuel. Efficacy of a Gas Permeable Contact Lens to Induce Peripheral Myopic Defocus, Optometry and Vision Science, 92, 5, 596-603, 2015.
1040-5488
10.1097/OPX.0000000000000582
25875679
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv American Academy of Optometry (AAOPT)
publisher.none.fl_str_mv American Academy of Optometry (AAOPT)
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1777303820741640192