Resumo: Intertrochanteric fracture is the most frequent type of fracture in the proximal femur and the compressive hip screw is one of the most popular methods of treatment. The reduction criteria for this type of fracture are ill-defined. The purpose of this study was to validate 3 reduction criteria: displacement, alignment in the anteroposterior and in the lateral plane. We reviewed a cohort of 430 intertrochanteric fractures treated with a compression hip screw. The type of fracture, quality of reduction and technical complications were noted. We observed a relationship between accuracy of reduction and the incidence of complications, even among fractures of the same severity. A displacement bigger than 4mm and failure to accomplish correct alignment (a neck-shaft angle over 125 masculine and less than 20 degrees angulation on the lateral view) was considered a poor reduction and was associated with more complications.
id RCAP_7571750b3aba6867284f5367a3495a7b
oai_identifier_str oai:repositorio.chlc.min-saude.pt:10400.17/2979
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Complications Relating to Accuracy of Reduction of Intertrochanteric Fractures Treated with a Compressive Hip ScrewAgedAged, 80 and overBiomechanical PhenomenaBone ScrewsFemaleFracture Fixation, InternalFractures, MalunitedHip FracturesHumansMaleMiddle AgedRadiographyRetrospective StudiesHCC ORTIntertrochanteric fracture is the most frequent type of fracture in the proximal femur and the compressive hip screw is one of the most popular methods of treatment. The reduction criteria for this type of fracture are ill-defined. The purpose of this study was to validate 3 reduction criteria: displacement, alignment in the anteroposterior and in the lateral plane. We reviewed a cohort of 430 intertrochanteric fractures treated with a compression hip screw. The type of fracture, quality of reduction and technical complications were noted. We observed a relationship between accuracy of reduction and the incidence of complications, even among fractures of the same severity. A displacement bigger than 4mm and failure to accomplish correct alignment (a neck-shaft angle over 125 masculine and less than 20 degrees angulation on the lateral view) was considered a poor reduction and was associated with more complications.WichtigRepositório do Centro Hospitalar Universitário de Lisboa Central, EPEGuerra Pinto, FDantas, PMoreira, RMamede, RAmaral, L2018-05-22T15:41:43Z20102010-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.17/2979engHip Int. 2010 Apr-Jun;20(2):221-8.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-03-10T09:40:37Zoai:repositorio.chlc.min-saude.pt:10400.17/2979Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T17:20:17.775154Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Complications Relating to Accuracy of Reduction of Intertrochanteric Fractures Treated with a Compressive Hip Screw
title Complications Relating to Accuracy of Reduction of Intertrochanteric Fractures Treated with a Compressive Hip Screw
spellingShingle Complications Relating to Accuracy of Reduction of Intertrochanteric Fractures Treated with a Compressive Hip Screw
Guerra Pinto, F
Aged
Aged, 80 and over
Biomechanical Phenomena
Bone Screws
Female
Fracture Fixation, Internal
Fractures, Malunited
Hip Fractures
Humans
Male
Middle Aged
Radiography
Retrospective Studies
HCC ORT
title_short Complications Relating to Accuracy of Reduction of Intertrochanteric Fractures Treated with a Compressive Hip Screw
title_full Complications Relating to Accuracy of Reduction of Intertrochanteric Fractures Treated with a Compressive Hip Screw
title_fullStr Complications Relating to Accuracy of Reduction of Intertrochanteric Fractures Treated with a Compressive Hip Screw
title_full_unstemmed Complications Relating to Accuracy of Reduction of Intertrochanteric Fractures Treated with a Compressive Hip Screw
title_sort Complications Relating to Accuracy of Reduction of Intertrochanteric Fractures Treated with a Compressive Hip Screw
author Guerra Pinto, F
author_facet Guerra Pinto, F
Dantas, P
Moreira, R
Mamede, R
Amaral, L
author_role author
author2 Dantas, P
Moreira, R
Mamede, R
Amaral, L
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Repositório do Centro Hospitalar Universitário de Lisboa Central, EPE
dc.contributor.author.fl_str_mv Guerra Pinto, F
Dantas, P
Moreira, R
Mamede, R
Amaral, L
dc.subject.por.fl_str_mv Aged
Aged, 80 and over
Biomechanical Phenomena
Bone Screws
Female
Fracture Fixation, Internal
Fractures, Malunited
Hip Fractures
Humans
Male
Middle Aged
Radiography
Retrospective Studies
HCC ORT
topic Aged
Aged, 80 and over
Biomechanical Phenomena
Bone Screws
Female
Fracture Fixation, Internal
Fractures, Malunited
Hip Fractures
Humans
Male
Middle Aged
Radiography
Retrospective Studies
HCC ORT
description Intertrochanteric fracture is the most frequent type of fracture in the proximal femur and the compressive hip screw is one of the most popular methods of treatment. The reduction criteria for this type of fracture are ill-defined. The purpose of this study was to validate 3 reduction criteria: displacement, alignment in the anteroposterior and in the lateral plane. We reviewed a cohort of 430 intertrochanteric fractures treated with a compression hip screw. The type of fracture, quality of reduction and technical complications were noted. We observed a relationship between accuracy of reduction and the incidence of complications, even among fractures of the same severity. A displacement bigger than 4mm and failure to accomplish correct alignment (a neck-shaft angle over 125 masculine and less than 20 degrees angulation on the lateral view) was considered a poor reduction and was associated with more complications.
publishDate 2010
dc.date.none.fl_str_mv 2010
2010-01-01T00:00:00Z
2018-05-22T15:41:43Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.17/2979
url http://hdl.handle.net/10400.17/2979
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Hip Int. 2010 Apr-Jun;20(2):221-8.
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Wichtig
publisher.none.fl_str_mv Wichtig
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799131298833367040