Reliability and validity of the Pittsburgh Sleep Quality Index in breast cancer patients

Detalhes bibliográficos
Autor(a) principal: Fontes, F
Data de Publicação: 2017
Outros Autores: Gonçalves, M, Maia, S, Pereira, S, Severo, M, Lunet, N
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10216/111758
Resumo: Purpose: We aimed to assess the factor structure, internal consistency, test-retest reliability, and construct validity of the European Portuguese version of the Pittsburgh Sleep Quality Index (PSQI) in breast cancer patients. Methods: This study was based on a cohort of breast cancer patients, among whom the PSQI was used to measure sleep quality three years after cancer diagnosis (N = 474). A sample of 62 participants underwent additional PSQI testing, wore a wrist actigraph for five consecutive days, and was reevaluated with the PSQI after one month. A confirmatory factor analysis, considering the components suggested by the principal component analysis (PCA), was performed to determine model fit. To evaluate internal consistency and test-retest reliability, Cronbach’s alpha and intraclass correlation coefficient (ICC) were calculated, respectively. To assess construct validity, Spearman’s correlation coefficients were computed between PSQI scores and actigraphy measures and other theoretical related constructs. Results: PCA suggested one or two components. The latter showed better fit to the data, though the two factors were strongly correlated (r = 0.76) and internal consistency was not satisfactory for one of the factors. Regarding the one-factor model, internal consistency (Cronbach’s alpha = 0.70) and test-retest reliability (ICC = 0.76) were adequate. Sleep duration, habitual sleep efficiency, and sleep disturbance dimensions were significantly correlated with the corresponding actigraphy measures; the PSQI global score derived from the one-factor model was more strongly correlated with subjective sleep complaints (r ≥ 0.60). Conclusions: The unidimensional construct of the European Portuguese version of the PSQI showed adequate reliability and validity among breast cancer patients.
id RCAP_96cf9303c6d128323c72867689c5649b
oai_identifier_str oai:repositorio-aberto.up.pt:10216/111758
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Reliability and validity of the Pittsburgh Sleep Quality Index in breast cancer patientsPittsburgh Sleep Quality IndexBreast cancer - PatientsPurpose: We aimed to assess the factor structure, internal consistency, test-retest reliability, and construct validity of the European Portuguese version of the Pittsburgh Sleep Quality Index (PSQI) in breast cancer patients. Methods: This study was based on a cohort of breast cancer patients, among whom the PSQI was used to measure sleep quality three years after cancer diagnosis (N = 474). A sample of 62 participants underwent additional PSQI testing, wore a wrist actigraph for five consecutive days, and was reevaluated with the PSQI after one month. A confirmatory factor analysis, considering the components suggested by the principal component analysis (PCA), was performed to determine model fit. To evaluate internal consistency and test-retest reliability, Cronbach’s alpha and intraclass correlation coefficient (ICC) were calculated, respectively. To assess construct validity, Spearman’s correlation coefficients were computed between PSQI scores and actigraphy measures and other theoretical related constructs. Results: PCA suggested one or two components. The latter showed better fit to the data, though the two factors were strongly correlated (r = 0.76) and internal consistency was not satisfactory for one of the factors. Regarding the one-factor model, internal consistency (Cronbach’s alpha = 0.70) and test-retest reliability (ICC = 0.76) were adequate. Sleep duration, habitual sleep efficiency, and sleep disturbance dimensions were significantly correlated with the corresponding actigraphy measures; the PSQI global score derived from the one-factor model was more strongly correlated with subjective sleep complaints (r ≥ 0.60). Conclusions: The unidimensional construct of the European Portuguese version of the PSQI showed adequate reliability and validity among breast cancer patients.Springer Berlin Heidelberg20172017-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfapplication/pdfhttp://hdl.handle.net/10216/111758eng1433-733910.1007/s00520-017-3713-9Fontes, FGonçalves, MMaia, SPereira, SSevero, MLunet, Ninfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-11-29T14:06:12Zoai:repositorio-aberto.up.pt:10216/111758Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T23:54:49.777411Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Reliability and validity of the Pittsburgh Sleep Quality Index in breast cancer patients
title Reliability and validity of the Pittsburgh Sleep Quality Index in breast cancer patients
spellingShingle Reliability and validity of the Pittsburgh Sleep Quality Index in breast cancer patients
Fontes, F
Pittsburgh Sleep Quality Index
Breast cancer - Patients
title_short Reliability and validity of the Pittsburgh Sleep Quality Index in breast cancer patients
title_full Reliability and validity of the Pittsburgh Sleep Quality Index in breast cancer patients
title_fullStr Reliability and validity of the Pittsburgh Sleep Quality Index in breast cancer patients
title_full_unstemmed Reliability and validity of the Pittsburgh Sleep Quality Index in breast cancer patients
title_sort Reliability and validity of the Pittsburgh Sleep Quality Index in breast cancer patients
author Fontes, F
author_facet Fontes, F
Gonçalves, M
Maia, S
Pereira, S
Severo, M
Lunet, N
author_role author
author2 Gonçalves, M
Maia, S
Pereira, S
Severo, M
Lunet, N
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Fontes, F
Gonçalves, M
Maia, S
Pereira, S
Severo, M
Lunet, N
dc.subject.por.fl_str_mv Pittsburgh Sleep Quality Index
Breast cancer - Patients
topic Pittsburgh Sleep Quality Index
Breast cancer - Patients
description Purpose: We aimed to assess the factor structure, internal consistency, test-retest reliability, and construct validity of the European Portuguese version of the Pittsburgh Sleep Quality Index (PSQI) in breast cancer patients. Methods: This study was based on a cohort of breast cancer patients, among whom the PSQI was used to measure sleep quality three years after cancer diagnosis (N = 474). A sample of 62 participants underwent additional PSQI testing, wore a wrist actigraph for five consecutive days, and was reevaluated with the PSQI after one month. A confirmatory factor analysis, considering the components suggested by the principal component analysis (PCA), was performed to determine model fit. To evaluate internal consistency and test-retest reliability, Cronbach’s alpha and intraclass correlation coefficient (ICC) were calculated, respectively. To assess construct validity, Spearman’s correlation coefficients were computed between PSQI scores and actigraphy measures and other theoretical related constructs. Results: PCA suggested one or two components. The latter showed better fit to the data, though the two factors were strongly correlated (r = 0.76) and internal consistency was not satisfactory for one of the factors. Regarding the one-factor model, internal consistency (Cronbach’s alpha = 0.70) and test-retest reliability (ICC = 0.76) were adequate. Sleep duration, habitual sleep efficiency, and sleep disturbance dimensions were significantly correlated with the corresponding actigraphy measures; the PSQI global score derived from the one-factor model was more strongly correlated with subjective sleep complaints (r ≥ 0.60). Conclusions: The unidimensional construct of the European Portuguese version of the PSQI showed adequate reliability and validity among breast cancer patients.
publishDate 2017
dc.date.none.fl_str_mv 2017
2017-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10216/111758
url http://hdl.handle.net/10216/111758
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1433-7339
10.1007/s00520-017-3713-9
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.publisher.none.fl_str_mv Springer Berlin Heidelberg
publisher.none.fl_str_mv Springer Berlin Heidelberg
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799135868684861440