Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity

Detalhes bibliográficos
Autor(a) principal: Machado, Vanessa
Data de Publicação: 2018
Outros Autores: Botelho, João, Mascarenhas, Paulo, Cavacas, Maria Alzira, Alves, Ricardo, Mendes, José João
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.26/33669
Resumo: This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
id RCAP_9c3f41fb33ea665543912d8e18d251b5
oai_identifier_str oai:comum.rcaap.pt:10400.26/33669
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificityBiasEpidemiologyPeriodontal attachment lossPeriodontal indexPeriodontal pocketPrevalenceThis is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).Objectives: This study aimed to assess bias magnitudes, sensibility, and specificity of particular partial-mouth recording protocols (PRPs) to estimate periodontal clinical measurements and periodontal status. Methods: Estimates of mean clinical attachment loss (MCAL) and mean probing depth (MPD) were calculated for 15 different PRPs and were compared to full-mouth recording protocol (FRP) data from 402 Portuguese. Biases, relative biases and intra-class correlations for all PRPs were evaluated. Bland–Altman plots and Receiver Operating Characteristic / Area Under the Curve (ROC/AUC) analysis were used to assess the sensitivity and specificity for each PRP periodontal diagnosis. Results: Regarding MPD, Half RD6 UR/LL and RD6 UL/LR had the lowest bias observed with 0.00 mm (-0.22% and 0.22%, respectively) and all full-mouth PRPs significantly produce an underestimation. Concerning MCAL, the Half MB-B-DL UR/LR had the lowest bias observed with 0.01 mm (0.16%). Excluding CPITN, Full-Mouth PRPs outperforms in average Half Mouth PRPs correlations. The Half RD6 UR/LL had the highest AUC (0.96) with 95.5 and 97.1% of sensitivity and specificity, respectively. Conclusions: Three half-mouth PRPs (Half MB-B-DL UR/LR, Half RD6 UR/LL and Half RD6 UL/ LR) protocols can be used to estimate periodontal clinical measurements with limited bias, and high sensitivity, specificity, and concordance. All full-mouth PRPs failed to estimate pocket depth means, and for clinical attachment loss, they present less ability then half-mouth partial protocols, despite presenting high sensitivity levels.Sociedade Portuguesa de Estomatologia e Medicina DentáriaRepositório ComumMachado, VanessaBotelho, JoãoMascarenhas, PauloCavacas, Maria AlziraAlves, RicardoMendes, José João2020-10-20T10:17:25Z2018-11-01T00:00:00Z2018-11-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.26/33669engMachado V, Botelho J, Mascarenhas P, Cavacas MA, Alves R, Mendes JJ; Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity. Rev Port Estomatol Med Dent Cir Maxilofac . 2018;59(3):145-1531646-289010.24873/j.rpemd.2018.11.239info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-10-06T14:54:08Zoai:comum.rcaap.pt:10400.26/33669Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T15:09:54.652037Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity
title Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity
spellingShingle Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity
Machado, Vanessa
Bias
Epidemiology
Periodontal attachment loss
Periodontal index
Periodontal pocket
Prevalence
title_short Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity
title_full Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity
title_fullStr Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity
title_full_unstemmed Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity
title_sort Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity
author Machado, Vanessa
author_facet Machado, Vanessa
Botelho, João
Mascarenhas, Paulo
Cavacas, Maria Alzira
Alves, Ricardo
Mendes, José João
author_role author
author2 Botelho, João
Mascarenhas, Paulo
Cavacas, Maria Alzira
Alves, Ricardo
Mendes, José João
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório Comum
dc.contributor.author.fl_str_mv Machado, Vanessa
Botelho, João
Mascarenhas, Paulo
Cavacas, Maria Alzira
Alves, Ricardo
Mendes, José João
dc.subject.por.fl_str_mv Bias
Epidemiology
Periodontal attachment loss
Periodontal index
Periodontal pocket
Prevalence
topic Bias
Epidemiology
Periodontal attachment loss
Periodontal index
Periodontal pocket
Prevalence
description This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
publishDate 2018
dc.date.none.fl_str_mv 2018-11-01T00:00:00Z
2018-11-01T00:00:00Z
2020-10-20T10:17:25Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.26/33669
url http://hdl.handle.net/10400.26/33669
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Machado V, Botelho J, Mascarenhas P, Cavacas MA, Alves R, Mendes JJ; Partial recording protocols performance on the assessment of Periodontitis severity and extent: bias magnitudes, sensibility, and specificity. Rev Port Estomatol Med Dent Cir Maxilofac . 2018;59(3):145-153
1646-2890
10.24873/j.rpemd.2018.11.239
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Sociedade Portuguesa de Estomatologia e Medicina Dentária
publisher.none.fl_str_mv Sociedade Portuguesa de Estomatologia e Medicina Dentária
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799129968928620544