Comparison of Four Natural Ventilation Systems in a Mediterranean Greenhouse

Bibliographic Details
Main Author: Coelho, M.
Publication Date: 2006
Other Authors: Baptista, F.J., Fitas da Cruz, Vasco, Garcia, José Luís
Format: Article
Language: eng
Source: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Download full: http://hdl.handle.net/10174/3099
Summary: Ventilation is one of the most important tools for controlling the greenhouse climate, influencing the environmental conditions such as temperature, humidity and carbon dioxide concentration, which affect the development and production of the crop. Natural ventilation is the result of the action of two natural forces, wind and thermal buoyancy. The main objectives of this study were to: 1). compare the behaviour of internal air parameters such as air temperature and humidity in a greenhouse with different management of natural ventilation and 2). calibrate and validate a climatic model. The study was based on experiments carried out in a greenhouse located at the ETSIA-Universidad Politecnica de Madrid, with floor area of 132 m2. The greenhouse was equipped with roof and side vents along the entire length. Four different systems (S) were studied, both roof and side openings (S1, A1=21.3 m2) and only roof openings (S2, A2=12.3 m2; S3, A3=7.9 m2 and S4, A4=4.4 m2). External and internal climatic parameters, such as air temperature, relative humidity, solar radiation and wind speed were measured and recorded using a data logger. All the data were recorded during several days for the different systems. Data of internal air temperature and water vapour pressure difference were analysed and compared between the different systems. In this study, ventilation rates were calculated using a model based on wind and buoyancy forces, assuming that total ventilation is due to the combined effect of both natural forces. Ventilation rates were then related to internal air conditions. Temperature differences between inside and outside varied within a range of 3.3 ºC (S1) and 10.6 ºC (S4), presenting an inverse proportionality to the ventilation area. The vapour pressure difference presented the highest value (0.111 kPa) for S2 and the lowest (0.011 kPa) for S3. A climatic model, based on energy and mass balances, allowing the prediction of internal air temperature and relative humidity, was calibrated and validated for the different ventilation systems. Partial data were used to calibrate the model and another set of data from different periods was used for model validation. Measured and predicted data were comparatively close.
id RCAP_a3e4948a4f9b030fe3744bd256a071ba
oai_identifier_str oai:dspace.uevora.pt:10174/3099
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Comparison of Four Natural Ventilation Systems in a Mediterranean Greenhousenatural ventilationgreenhousesmodellingVentilation is one of the most important tools for controlling the greenhouse climate, influencing the environmental conditions such as temperature, humidity and carbon dioxide concentration, which affect the development and production of the crop. Natural ventilation is the result of the action of two natural forces, wind and thermal buoyancy. The main objectives of this study were to: 1). compare the behaviour of internal air parameters such as air temperature and humidity in a greenhouse with different management of natural ventilation and 2). calibrate and validate a climatic model. The study was based on experiments carried out in a greenhouse located at the ETSIA-Universidad Politecnica de Madrid, with floor area of 132 m2. The greenhouse was equipped with roof and side vents along the entire length. Four different systems (S) were studied, both roof and side openings (S1, A1=21.3 m2) and only roof openings (S2, A2=12.3 m2; S3, A3=7.9 m2 and S4, A4=4.4 m2). External and internal climatic parameters, such as air temperature, relative humidity, solar radiation and wind speed were measured and recorded using a data logger. All the data were recorded during several days for the different systems. Data of internal air temperature and water vapour pressure difference were analysed and compared between the different systems. In this study, ventilation rates were calculated using a model based on wind and buoyancy forces, assuming that total ventilation is due to the combined effect of both natural forces. Ventilation rates were then related to internal air conditions. Temperature differences between inside and outside varied within a range of 3.3 ºC (S1) and 10.6 ºC (S4), presenting an inverse proportionality to the ventilation area. The vapour pressure difference presented the highest value (0.111 kPa) for S2 and the lowest (0.011 kPa) for S3. A climatic model, based on energy and mass balances, allowing the prediction of internal air temperature and relative humidity, was calibrated and validated for the different ventilation systems. Partial data were used to calibrate the model and another set of data from different periods was used for model validation. Measured and predicted data were comparatively close.Elsevier2012-01-09T10:24:50Z2012-01-092006-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10174/3099http://hdl.handle.net/10174/3099engCOELHO M, BAPTISTA FJ, FITAS DA CRUZ V and GARCIA JL. 2006. Comparison of Four Natural Ventilation Strategies in a Mediterranean Greenhouse. Acta Horticulturae 719:157-164Partilhar com ICAAMndfb@uevora.ptvfc@uevora.ptnd580Coelho, M.Baptista, F.J.Fitas da Cruz, VascoGarcia, José Luísinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-01-03T18:40:07Zoai:dspace.uevora.pt:10174/3099Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T00:58:41.249619Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Comparison of Four Natural Ventilation Systems in a Mediterranean Greenhouse
title Comparison of Four Natural Ventilation Systems in a Mediterranean Greenhouse
spellingShingle Comparison of Four Natural Ventilation Systems in a Mediterranean Greenhouse
Coelho, M.
natural ventilation
greenhouses
modelling
title_short Comparison of Four Natural Ventilation Systems in a Mediterranean Greenhouse
title_full Comparison of Four Natural Ventilation Systems in a Mediterranean Greenhouse
title_fullStr Comparison of Four Natural Ventilation Systems in a Mediterranean Greenhouse
title_full_unstemmed Comparison of Four Natural Ventilation Systems in a Mediterranean Greenhouse
title_sort Comparison of Four Natural Ventilation Systems in a Mediterranean Greenhouse
author Coelho, M.
author_facet Coelho, M.
Baptista, F.J.
Fitas da Cruz, Vasco
Garcia, José Luís
author_role author
author2 Baptista, F.J.
Fitas da Cruz, Vasco
Garcia, José Luís
author2_role author
author
author
dc.contributor.author.fl_str_mv Coelho, M.
Baptista, F.J.
Fitas da Cruz, Vasco
Garcia, José Luís
dc.subject.por.fl_str_mv natural ventilation
greenhouses
modelling
topic natural ventilation
greenhouses
modelling
description Ventilation is one of the most important tools for controlling the greenhouse climate, influencing the environmental conditions such as temperature, humidity and carbon dioxide concentration, which affect the development and production of the crop. Natural ventilation is the result of the action of two natural forces, wind and thermal buoyancy. The main objectives of this study were to: 1). compare the behaviour of internal air parameters such as air temperature and humidity in a greenhouse with different management of natural ventilation and 2). calibrate and validate a climatic model. The study was based on experiments carried out in a greenhouse located at the ETSIA-Universidad Politecnica de Madrid, with floor area of 132 m2. The greenhouse was equipped with roof and side vents along the entire length. Four different systems (S) were studied, both roof and side openings (S1, A1=21.3 m2) and only roof openings (S2, A2=12.3 m2; S3, A3=7.9 m2 and S4, A4=4.4 m2). External and internal climatic parameters, such as air temperature, relative humidity, solar radiation and wind speed were measured and recorded using a data logger. All the data were recorded during several days for the different systems. Data of internal air temperature and water vapour pressure difference were analysed and compared between the different systems. In this study, ventilation rates were calculated using a model based on wind and buoyancy forces, assuming that total ventilation is due to the combined effect of both natural forces. Ventilation rates were then related to internal air conditions. Temperature differences between inside and outside varied within a range of 3.3 ºC (S1) and 10.6 ºC (S4), presenting an inverse proportionality to the ventilation area. The vapour pressure difference presented the highest value (0.111 kPa) for S2 and the lowest (0.011 kPa) for S3. A climatic model, based on energy and mass balances, allowing the prediction of internal air temperature and relative humidity, was calibrated and validated for the different ventilation systems. Partial data were used to calibrate the model and another set of data from different periods was used for model validation. Measured and predicted data were comparatively close.
publishDate 2006
dc.date.none.fl_str_mv 2006-01-01T00:00:00Z
2012-01-09T10:24:50Z
2012-01-09
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10174/3099
http://hdl.handle.net/10174/3099
url http://hdl.handle.net/10174/3099
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv COELHO M, BAPTISTA FJ, FITAS DA CRUZ V and GARCIA JL. 2006. Comparison of Four Natural Ventilation Strategies in a Mediterranean Greenhouse. Acta Horticulturae 719:157-164
Partilhar com ICAAM
nd
fb@uevora.pt
vfc@uevora.pt
nd
580
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.publisher.none.fl_str_mv Elsevier
publisher.none.fl_str_mv Elsevier
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799136470196289536