Rehabilitation of the Roof Timber Trusses of a Multiuse Pavilion

Detalhes bibliográficos
Autor(a) principal: Negrão, João H.
Data de Publicação: 2020
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/101468
https://doi.org/10.28991/cej-2020-03091628
Resumo: This paper describes the rehabilitation procedure of the roof timber structure of a multiuse pavilion in Viseu, Portugal. The roof structure consists of a series of parallel double timber trusses, partially concealed above a polyhedral wooden plank-made ceiling. Recently, the support of one of the trusses failed and another one has been assessed as in a pre-failure condition. Some load-redistribution and the prompt shore of the structure prevented the generalized collapse. The subsequent inspection and assessment led to the conclusion that the primary cause of the collapse was the failure perpendicular to the grain of the solid timber elements inserted between the double rafters and tie-beams. The replacement of the existing with a steel structure, and the repair and reinforcement of the existing wooden trusses, were considered as intervention possibilities. The latter revealed much cheaper, less time-consuming and in line with the international recommendations on rehabilitation works, and was therefore adopted. An innovative solution, consisting of the replacement of the central timber elements in all the supports, resulted in minimum visual impact and improved the load bearing capability beyond its original value.
id RCAP_ac50762edaf08179d9675dabc64cecf3
oai_identifier_str oai:estudogeral.uc.pt:10316/101468
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Rehabilitation of the Roof Timber Trusses of a Multiuse PavilionTimber StructuresRehabilitationStrengtheningConstruction ProcessProsthesisThis paper describes the rehabilitation procedure of the roof timber structure of a multiuse pavilion in Viseu, Portugal. The roof structure consists of a series of parallel double timber trusses, partially concealed above a polyhedral wooden plank-made ceiling. Recently, the support of one of the trusses failed and another one has been assessed as in a pre-failure condition. Some load-redistribution and the prompt shore of the structure prevented the generalized collapse. The subsequent inspection and assessment led to the conclusion that the primary cause of the collapse was the failure perpendicular to the grain of the solid timber elements inserted between the double rafters and tie-beams. The replacement of the existing with a steel structure, and the repair and reinforcement of the existing wooden trusses, were considered as intervention possibilities. The latter revealed much cheaper, less time-consuming and in line with the international recommendations on rehabilitation works, and was therefore adopted. An innovative solution, consisting of the replacement of the central timber elements in all the supports, resulted in minimum visual impact and improved the load bearing capability beyond its original value.2020info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://hdl.handle.net/10316/101468http://hdl.handle.net/10316/101468https://doi.org/10.28991/cej-2020-03091628eng2476-30552676-6957Negrão, João H.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-08-26T20:57:03Zoai:estudogeral.uc.pt:10316/101468Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T21:18:39.332294Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Rehabilitation of the Roof Timber Trusses of a Multiuse Pavilion
title Rehabilitation of the Roof Timber Trusses of a Multiuse Pavilion
spellingShingle Rehabilitation of the Roof Timber Trusses of a Multiuse Pavilion
Negrão, João H.
Timber Structures
Rehabilitation
Strengthening
Construction Process
Prosthesis
title_short Rehabilitation of the Roof Timber Trusses of a Multiuse Pavilion
title_full Rehabilitation of the Roof Timber Trusses of a Multiuse Pavilion
title_fullStr Rehabilitation of the Roof Timber Trusses of a Multiuse Pavilion
title_full_unstemmed Rehabilitation of the Roof Timber Trusses of a Multiuse Pavilion
title_sort Rehabilitation of the Roof Timber Trusses of a Multiuse Pavilion
author Negrão, João H.
author_facet Negrão, João H.
author_role author
dc.contributor.author.fl_str_mv Negrão, João H.
dc.subject.por.fl_str_mv Timber Structures
Rehabilitation
Strengthening
Construction Process
Prosthesis
topic Timber Structures
Rehabilitation
Strengthening
Construction Process
Prosthesis
description This paper describes the rehabilitation procedure of the roof timber structure of a multiuse pavilion in Viseu, Portugal. The roof structure consists of a series of parallel double timber trusses, partially concealed above a polyhedral wooden plank-made ceiling. Recently, the support of one of the trusses failed and another one has been assessed as in a pre-failure condition. Some load-redistribution and the prompt shore of the structure prevented the generalized collapse. The subsequent inspection and assessment led to the conclusion that the primary cause of the collapse was the failure perpendicular to the grain of the solid timber elements inserted between the double rafters and tie-beams. The replacement of the existing with a steel structure, and the repair and reinforcement of the existing wooden trusses, were considered as intervention possibilities. The latter revealed much cheaper, less time-consuming and in line with the international recommendations on rehabilitation works, and was therefore adopted. An innovative solution, consisting of the replacement of the central timber elements in all the supports, resulted in minimum visual impact and improved the load bearing capability beyond its original value.
publishDate 2020
dc.date.none.fl_str_mv 2020
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/101468
http://hdl.handle.net/10316/101468
https://doi.org/10.28991/cej-2020-03091628
url http://hdl.handle.net/10316/101468
https://doi.org/10.28991/cej-2020-03091628
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 2476-3055
2676-6957
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799134081007484928