The effect of metoclopramide in capsule enteroscopy

Detalhes bibliográficos
Autor(a) principal: Almeida, N
Data de Publicação: 2010
Outros Autores: Figueiredo, P, Freire, P, Lopes, S, Lérias, C, Gouveia, H, Leitão, MC
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.4/1918
Resumo: Clinical utility of prokinetics in capsule endoscopy (CE) is not clearly established. The objective of this prospective, randomized, single-blind, controlled trial was to determine if metoclopramide is useful in CE by increasing the rate of complete enteroscopy. Ninety-five patients referred for CE were randomized to no metoclopramide (group B, n = 48) or 10 mg metoclopramide (group A, n = 47). Complete enteroscopy was possible in 38 patients of group A (80.9%) and 37 of group B (77.1%) (P = 0.422) with two cases of gastric retention in group B (4.2%; P = 0.253). Median gastric transit time was 26 min (1-211) in group A and 28 min (4-200) in group B (P = 0.511). Mean small bowel transit time, calculated after excluding 20 patients with incomplete enteroscopy, was similar in both groups (221.2 +/- 89 min vs. 256 +/- 82.2 min; P = 0.083). There were also no differences in the total number of findings (group A 4.5 +/- 4.7; group B 4.7 +/- 3.7, P = 0.815). Administration of 10 mg metoclopramide orally 15 min before capsule ingestion did not significantly increase the rate of total enteroscopies and had no effect on transit times. It also did not modify CE diagnostic yield.
id RCAP_b16ecac309557a39ba646a2bacbb3c28
oai_identifier_str oai:rihuc.huc.min-saude.pt:10400.4/1918
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str
spelling The effect of metoclopramide in capsule enteroscopyEndoscopia por CápsulaMetoclopramidaPré-MedicaçãoClinical utility of prokinetics in capsule endoscopy (CE) is not clearly established. The objective of this prospective, randomized, single-blind, controlled trial was to determine if metoclopramide is useful in CE by increasing the rate of complete enteroscopy. Ninety-five patients referred for CE were randomized to no metoclopramide (group B, n = 48) or 10 mg metoclopramide (group A, n = 47). Complete enteroscopy was possible in 38 patients of group A (80.9%) and 37 of group B (77.1%) (P = 0.422) with two cases of gastric retention in group B (4.2%; P = 0.253). Median gastric transit time was 26 min (1-211) in group A and 28 min (4-200) in group B (P = 0.511). Mean small bowel transit time, calculated after excluding 20 patients with incomplete enteroscopy, was similar in both groups (221.2 +/- 89 min vs. 256 +/- 82.2 min; P = 0.083). There were also no differences in the total number of findings (group A 4.5 +/- 4.7; group B 4.7 +/- 3.7, P = 0.815). Administration of 10 mg metoclopramide orally 15 min before capsule ingestion did not significantly increase the rate of total enteroscopies and had no effect on transit times. It also did not modify CE diagnostic yield.RIHUCAlmeida, NFigueiredo, PFreire, PLopes, SLérias, CGouveia, HLeitão, MC2016-05-12T09:53:28Z2010-012010-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.4/1918engDig Dis Sci. 2010 Jan;55(1):153-7.10.1007/s10620-008-0687-yinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-11T14:23:12ZPortal AgregadorONG
dc.title.none.fl_str_mv The effect of metoclopramide in capsule enteroscopy
title The effect of metoclopramide in capsule enteroscopy
spellingShingle The effect of metoclopramide in capsule enteroscopy
Almeida, N
Endoscopia por Cápsula
Metoclopramida
Pré-Medicação
title_short The effect of metoclopramide in capsule enteroscopy
title_full The effect of metoclopramide in capsule enteroscopy
title_fullStr The effect of metoclopramide in capsule enteroscopy
title_full_unstemmed The effect of metoclopramide in capsule enteroscopy
title_sort The effect of metoclopramide in capsule enteroscopy
author Almeida, N
author_facet Almeida, N
Figueiredo, P
Freire, P
Lopes, S
Lérias, C
Gouveia, H
Leitão, MC
author_role author
author2 Figueiredo, P
Freire, P
Lopes, S
Lérias, C
Gouveia, H
Leitão, MC
author2_role author
author
author
author
author
author
dc.contributor.none.fl_str_mv RIHUC
dc.contributor.author.fl_str_mv Almeida, N
Figueiredo, P
Freire, P
Lopes, S
Lérias, C
Gouveia, H
Leitão, MC
dc.subject.por.fl_str_mv Endoscopia por Cápsula
Metoclopramida
Pré-Medicação
topic Endoscopia por Cápsula
Metoclopramida
Pré-Medicação
description Clinical utility of prokinetics in capsule endoscopy (CE) is not clearly established. The objective of this prospective, randomized, single-blind, controlled trial was to determine if metoclopramide is useful in CE by increasing the rate of complete enteroscopy. Ninety-five patients referred for CE were randomized to no metoclopramide (group B, n = 48) or 10 mg metoclopramide (group A, n = 47). Complete enteroscopy was possible in 38 patients of group A (80.9%) and 37 of group B (77.1%) (P = 0.422) with two cases of gastric retention in group B (4.2%; P = 0.253). Median gastric transit time was 26 min (1-211) in group A and 28 min (4-200) in group B (P = 0.511). Mean small bowel transit time, calculated after excluding 20 patients with incomplete enteroscopy, was similar in both groups (221.2 +/- 89 min vs. 256 +/- 82.2 min; P = 0.083). There were also no differences in the total number of findings (group A 4.5 +/- 4.7; group B 4.7 +/- 3.7, P = 0.815). Administration of 10 mg metoclopramide orally 15 min before capsule ingestion did not significantly increase the rate of total enteroscopies and had no effect on transit times. It also did not modify CE diagnostic yield.
publishDate 2010
dc.date.none.fl_str_mv 2010-01
2010-01-01T00:00:00Z
2016-05-12T09:53:28Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.4/1918
url http://hdl.handle.net/10400.4/1918
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Dig Dis Sci. 2010 Jan;55(1):153-7.
10.1007/s10620-008-0687-y
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1777303113854615552