Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detection

Detalhes bibliográficos
Autor(a) principal: Pena, Angelina
Data de Publicação: 2003
Outros Autores: Lino, Celeste, Silveira, M. Irene N.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10316/5779
https://doi.org/10.1016/S0731-7085(03)00190-0
Resumo: A gas chromatographic method for determination of ticlopidine in human plasma using mass spectrometric detection was developed. A Perkin Elmer model 8500 gas chromatograph coupled to an ion trap detector (ITD) in electron impact mode (EI) was used. The gas chromatograph was fitted with a 30 m×0.32 mm i.d., DB-17 capillary column with a film thickness of 0.25 [mu]m. The compounds were isolated from plasma by Extrelut-1 solid-phase extraction using hexane as the solvent of elution. The detection and quantification limits for this method were 0.005 and 0.01 [mu]g/ml, respectively. The calibration curves were linear from 0.01 and 2.5 [mu]g/ml. Recoveries from human plasma spiked at 0.01 and 2.0 [mu]g/ml ranged from 84.4 and 87.3%. The coefficient of variation (CV) was between 5.1 and 6.9%. The results show that the sensitivity, accuracy and precision of the method are adequate for the determination of ticlopidine in human plasma samples. The ITD in SIM mode allows the unequivocal identification of ticlopidine. The suitability of this method was evaluated in the determination of ticlopidine in plasma from healthy volunteers following oral administration of a dose of 500 mg/day.
id RCAP_d38151af67ebb6197c94cc87f3e1c2ae
oai_identifier_str oai:estudogeral.uc.pt:10316/5779
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str
spelling Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detectionTiclopidineHuman plasmaGas chromatography-mass spectrometric detectionA gas chromatographic method for determination of ticlopidine in human plasma using mass spectrometric detection was developed. A Perkin Elmer model 8500 gas chromatograph coupled to an ion trap detector (ITD) in electron impact mode (EI) was used. The gas chromatograph was fitted with a 30 m×0.32 mm i.d., DB-17 capillary column with a film thickness of 0.25 [mu]m. The compounds were isolated from plasma by Extrelut-1 solid-phase extraction using hexane as the solvent of elution. The detection and quantification limits for this method were 0.005 and 0.01 [mu]g/ml, respectively. The calibration curves were linear from 0.01 and 2.5 [mu]g/ml. Recoveries from human plasma spiked at 0.01 and 2.0 [mu]g/ml ranged from 84.4 and 87.3%. The coefficient of variation (CV) was between 5.1 and 6.9%. The results show that the sensitivity, accuracy and precision of the method are adequate for the determination of ticlopidine in human plasma samples. The ITD in SIM mode allows the unequivocal identification of ticlopidine. The suitability of this method was evaluated in the determination of ticlopidine in plasma from healthy volunteers following oral administration of a dose of 500 mg/day.http://www.sciencedirect.com/science/article/B6TGX-48R7F4V-2/1/7f0e17eaa3f9ec2ce371c06ae41c85772003info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleaplication/PDFhttp://hdl.handle.net/10316/5779http://hdl.handle.net/10316/5779https://doi.org/10.1016/S0731-7085(03)00190-0engJournal of Pharmaceutical and Biomedical Analysis. 32:4-5 (2003) 879-885Pena, AngelinaLino, CelesteSilveira, M. Irene N.info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2022-05-25T03:44:47ZPortal AgregadorONG
dc.title.none.fl_str_mv Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detection
title Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detection
spellingShingle Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detection
Pena, Angelina
Ticlopidine
Human plasma
Gas chromatography-mass spectrometric detection
title_short Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detection
title_full Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detection
title_fullStr Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detection
title_full_unstemmed Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detection
title_sort Determination of ticlopidine in human plasma by capillary gas chromatography with ion trap detection
author Pena, Angelina
author_facet Pena, Angelina
Lino, Celeste
Silveira, M. Irene N.
author_role author
author2 Lino, Celeste
Silveira, M. Irene N.
author2_role author
author
dc.contributor.author.fl_str_mv Pena, Angelina
Lino, Celeste
Silveira, M. Irene N.
dc.subject.por.fl_str_mv Ticlopidine
Human plasma
Gas chromatography-mass spectrometric detection
topic Ticlopidine
Human plasma
Gas chromatography-mass spectrometric detection
description A gas chromatographic method for determination of ticlopidine in human plasma using mass spectrometric detection was developed. A Perkin Elmer model 8500 gas chromatograph coupled to an ion trap detector (ITD) in electron impact mode (EI) was used. The gas chromatograph was fitted with a 30 m×0.32 mm i.d., DB-17 capillary column with a film thickness of 0.25 [mu]m. The compounds were isolated from plasma by Extrelut-1 solid-phase extraction using hexane as the solvent of elution. The detection and quantification limits for this method were 0.005 and 0.01 [mu]g/ml, respectively. The calibration curves were linear from 0.01 and 2.5 [mu]g/ml. Recoveries from human plasma spiked at 0.01 and 2.0 [mu]g/ml ranged from 84.4 and 87.3%. The coefficient of variation (CV) was between 5.1 and 6.9%. The results show that the sensitivity, accuracy and precision of the method are adequate for the determination of ticlopidine in human plasma samples. The ITD in SIM mode allows the unequivocal identification of ticlopidine. The suitability of this method was evaluated in the determination of ticlopidine in plasma from healthy volunteers following oral administration of a dose of 500 mg/day.
publishDate 2003
dc.date.none.fl_str_mv 2003
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10316/5779
http://hdl.handle.net/10316/5779
https://doi.org/10.1016/S0731-7085(03)00190-0
url http://hdl.handle.net/10316/5779
https://doi.org/10.1016/S0731-7085(03)00190-0
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Journal of Pharmaceutical and Biomedical Analysis. 32:4-5 (2003) 879-885
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv aplication/PDF
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1777302613315813376