Validation of an HPLC-DAD method for quercetin quantification in nanoparticles

Detalhes bibliográficos
Autor(a) principal: Carvalho, Daniel
Data de Publicação: 2023
Outros Autores: Jesus, Ângelo, Pinho, Cláudia, Ferraz Oliveira, Rita, Moreira, Fernando, Oliveira, Ana Isabel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/10400.22/24922
Resumo: The evaluation of the efficacy of incorporation of quercetin in nanoparticles is crucial, both for the development and quality control of pharmaceutical formulations. The validation of analytical methods for the precise quantification of quercetin is useful for the evaluation of various potential quercetin delivery systems and quercetin pharmacokinetics. This work aimed to validate a high-performance liquid chromatography with diode array detection (HPLC-DAD) method for quercetin detection and quantification in nanoparticles. Different mobile phase conditions and detection wavelengths (254 and 368 nm) were tested, and the major validation parameters were assessed (precision, accuracy, linearity, sensitivity, stability, and selectivity). The best peak resolution was obtained when quercetin was analyzed at 368 nm with a mobile phase of 1.5% acetic acid and a water/acetonitrile/methanol ratio of 55:40:5. Under these conditions, quercetin also eluted rapidly (retention time of 3.6 min). The method proved to be linear (R2 > 0.995), specific, and repeatable (variation coefficient between 2.4% and 6.7%) and presented intermediate precision (variation coefficient between 7.2% and 9.4%). The accuracy of the analysis ranged between 88.6% and 110.7%, and detection and quantification limits were 0.046 and 0.14 µg/mL, respectively. Quercetin solutions were more stable when stored at 4 °C than at room temperature or −20 °C. This validated method satisfied more parameters of bias assessment than most recent methods for quercetin determination and presented itself as more sensitive and efficient than general spectrophotometric methods. The method was successfully used for the analysis of quercetin incorporation in nanoparticles and will be evaluated in the future for its adequacy for the determination of quercetin in more complex matrices.
id RCAP_d8e04b3fc63be2b140bfbecf5f35eedb
oai_identifier_str oai:recipp.ipp.pt:10400.22/24922
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Validation of an HPLC-DAD method for quercetin quantification in nanoparticlesAnalysisChromatographyHPLCQuercetinValidationThe evaluation of the efficacy of incorporation of quercetin in nanoparticles is crucial, both for the development and quality control of pharmaceutical formulations. The validation of analytical methods for the precise quantification of quercetin is useful for the evaluation of various potential quercetin delivery systems and quercetin pharmacokinetics. This work aimed to validate a high-performance liquid chromatography with diode array detection (HPLC-DAD) method for quercetin detection and quantification in nanoparticles. Different mobile phase conditions and detection wavelengths (254 and 368 nm) were tested, and the major validation parameters were assessed (precision, accuracy, linearity, sensitivity, stability, and selectivity). The best peak resolution was obtained when quercetin was analyzed at 368 nm with a mobile phase of 1.5% acetic acid and a water/acetonitrile/methanol ratio of 55:40:5. Under these conditions, quercetin also eluted rapidly (retention time of 3.6 min). The method proved to be linear (R2 > 0.995), specific, and repeatable (variation coefficient between 2.4% and 6.7%) and presented intermediate precision (variation coefficient between 7.2% and 9.4%). The accuracy of the analysis ranged between 88.6% and 110.7%, and detection and quantification limits were 0.046 and 0.14 µg/mL, respectively. Quercetin solutions were more stable when stored at 4 °C than at room temperature or −20 °C. This validated method satisfied more parameters of bias assessment than most recent methods for quercetin determination and presented itself as more sensitive and efficient than general spectrophotometric methods. The method was successfully used for the analysis of quercetin incorporation in nanoparticles and will be evaluated in the future for its adequacy for the determination of quercetin in more complex matrices.MDPIRepositório Científico do Instituto Politécnico do PortoCarvalho, DanielJesus, ÂngeloPinho, CláudiaFerraz Oliveira, RitaMoreira, FernandoOliveira, Ana Isabel2024-02-01T10:19:40Z2023-12-172023-12-17T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.22/24922engCarvalho, D., Jesus, Â., Pinho, C., Oliveira, R. F., Moreira, F., & Oliveira, A. I. (2023). Validation of an HPLC-DAD method for quercetin quantification in nanoparticles. Pharmaceuticals, 16(12), Artigo 12. https://doi.org/10.3390/ph1612173610.3390/ph161217361424-8247info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2024-02-07T01:49:00Zoai:recipp.ipp.pt:10400.22/24922Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-20T02:36:35.574739Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Validation of an HPLC-DAD method for quercetin quantification in nanoparticles
title Validation of an HPLC-DAD method for quercetin quantification in nanoparticles
spellingShingle Validation of an HPLC-DAD method for quercetin quantification in nanoparticles
Carvalho, Daniel
Analysis
Chromatography
HPLC
Quercetin
Validation
title_short Validation of an HPLC-DAD method for quercetin quantification in nanoparticles
title_full Validation of an HPLC-DAD method for quercetin quantification in nanoparticles
title_fullStr Validation of an HPLC-DAD method for quercetin quantification in nanoparticles
title_full_unstemmed Validation of an HPLC-DAD method for quercetin quantification in nanoparticles
title_sort Validation of an HPLC-DAD method for quercetin quantification in nanoparticles
author Carvalho, Daniel
author_facet Carvalho, Daniel
Jesus, Ângelo
Pinho, Cláudia
Ferraz Oliveira, Rita
Moreira, Fernando
Oliveira, Ana Isabel
author_role author
author2 Jesus, Ângelo
Pinho, Cláudia
Ferraz Oliveira, Rita
Moreira, Fernando
Oliveira, Ana Isabel
author2_role author
author
author
author
author
dc.contributor.none.fl_str_mv Repositório Científico do Instituto Politécnico do Porto
dc.contributor.author.fl_str_mv Carvalho, Daniel
Jesus, Ângelo
Pinho, Cláudia
Ferraz Oliveira, Rita
Moreira, Fernando
Oliveira, Ana Isabel
dc.subject.por.fl_str_mv Analysis
Chromatography
HPLC
Quercetin
Validation
topic Analysis
Chromatography
HPLC
Quercetin
Validation
description The evaluation of the efficacy of incorporation of quercetin in nanoparticles is crucial, both for the development and quality control of pharmaceutical formulations. The validation of analytical methods for the precise quantification of quercetin is useful for the evaluation of various potential quercetin delivery systems and quercetin pharmacokinetics. This work aimed to validate a high-performance liquid chromatography with diode array detection (HPLC-DAD) method for quercetin detection and quantification in nanoparticles. Different mobile phase conditions and detection wavelengths (254 and 368 nm) were tested, and the major validation parameters were assessed (precision, accuracy, linearity, sensitivity, stability, and selectivity). The best peak resolution was obtained when quercetin was analyzed at 368 nm with a mobile phase of 1.5% acetic acid and a water/acetonitrile/methanol ratio of 55:40:5. Under these conditions, quercetin also eluted rapidly (retention time of 3.6 min). The method proved to be linear (R2 > 0.995), specific, and repeatable (variation coefficient between 2.4% and 6.7%) and presented intermediate precision (variation coefficient between 7.2% and 9.4%). The accuracy of the analysis ranged between 88.6% and 110.7%, and detection and quantification limits were 0.046 and 0.14 µg/mL, respectively. Quercetin solutions were more stable when stored at 4 °C than at room temperature or −20 °C. This validated method satisfied more parameters of bias assessment than most recent methods for quercetin determination and presented itself as more sensitive and efficient than general spectrophotometric methods. The method was successfully used for the analysis of quercetin incorporation in nanoparticles and will be evaluated in the future for its adequacy for the determination of quercetin in more complex matrices.
publishDate 2023
dc.date.none.fl_str_mv 2023-12-17
2023-12-17T00:00:00Z
2024-02-01T10:19:40Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/10400.22/24922
url http://hdl.handle.net/10400.22/24922
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Carvalho, D., Jesus, Â., Pinho, C., Oliveira, R. F., Moreira, F., & Oliveira, A. I. (2023). Validation of an HPLC-DAD method for quercetin quantification in nanoparticles. Pharmaceuticals, 16(12), Artigo 12. https://doi.org/10.3390/ph16121736
10.3390/ph16121736
1424-8247
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv MDPI
publisher.none.fl_str_mv MDPI
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799137416923054080