Adaptation to multifocal and monovision contact lens correction

Detalhes bibliográficos
Autor(a) principal: Fernandes, Paulo Rodrigues
Data de Publicação: 2013
Outros Autores: Neves, Helena, Ferreira, Daniela Lopes, Jorge, Jorge, González-Méijome, José Manuel
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/27018
Resumo: Purpose. To compare visual performance with the Biofinity multifocal (MF) contact lens with monovision (MV) with the Biofinity single-vision contact lens. Methods. A crossover study of 20 presbyopic patients was conducted. Patients were randomized first into either an MF or an MV lens for 15 days for each modality, with a washout period between each lens type. Measurements included monocular and binocular high- and low-contrast logarithm of the minimum angle of resolution visual acuity (VA) at distance and near visions, binocular distance contrast sensitivity function, and near stereoacuity. Results. At 15 days, patients lost fewer than two letters (half a line of VA) of binocular distance and near VA, with the MF and MV lens under high- and low-contrast conditions (P 9 0.05 for both comparisons). No statistically significant differences were seen in binocular VA at near or distance with either lens. However, the monocular distance VA improved significantly in the nondominant eye, with the MF lens by one line over the 15-day period under high-contrast (P = 0.023) and lowcontrast (P = 0.035) conditions; this effect was not seen with the MV lens. Contrast sensitivity function was within the normal limits with both lenses. The stereoacuity was significantly (P G 0.01) better with MF than with MV. Conclusions. Multifocal contact lens correction provided satisfactory levels of VA comparable with MV without compromising stereoacuity in this crossover study. The near vision significantly improved in the dominant eye, and the distance vision improved in the nondominant eye from 1 to 15 days with the MF lens, suggesting that patients adapted to the multifocality overtime, whereas this was not true for MV. (Optom Vis Sci 2013;90:228Y235)
id RCAP_e7b52819ba3b49201b3f25ee958170d2
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/27018
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str
spelling Adaptation to multifocal and monovision contact lens correctionMonovisionMultifocal contact lensesLogMAR visual acuityStereoacuitySubjective comfort and abilityScience & TechnologyPurpose. To compare visual performance with the Biofinity multifocal (MF) contact lens with monovision (MV) with the Biofinity single-vision contact lens. Methods. A crossover study of 20 presbyopic patients was conducted. Patients were randomized first into either an MF or an MV lens for 15 days for each modality, with a washout period between each lens type. Measurements included monocular and binocular high- and low-contrast logarithm of the minimum angle of resolution visual acuity (VA) at distance and near visions, binocular distance contrast sensitivity function, and near stereoacuity. Results. At 15 days, patients lost fewer than two letters (half a line of VA) of binocular distance and near VA, with the MF and MV lens under high- and low-contrast conditions (P 9 0.05 for both comparisons). No statistically significant differences were seen in binocular VA at near or distance with either lens. However, the monocular distance VA improved significantly in the nondominant eye, with the MF lens by one line over the 15-day period under high-contrast (P = 0.023) and lowcontrast (P = 0.035) conditions; this effect was not seen with the MV lens. Contrast sensitivity function was within the normal limits with both lenses. The stereoacuity was significantly (P G 0.01) better with MF than with MV. Conclusions. Multifocal contact lens correction provided satisfactory levels of VA comparable with MV without compromising stereoacuity in this crossover study. The near vision significantly improved in the dominant eye, and the distance vision improved in the nondominant eye from 1 to 15 days with the MF lens, suggesting that patients adapted to the multifocality overtime, whereas this was not true for MV. (Optom Vis Sci 2013;90:228Y235)The authors declare that they do not have any proprietary or financial interest in any of the materials mentioned in this article. This study has been funded by projects PTDC/SAU-BEB/098392/2008 and PTDC/SAU-BEB/098391/2008 funded by the Portuguese Fundacao para a Ciencia e Tecnologia through the European Social Fund. This study has been partly supported by an unrestricted grant from CooperVision.American Academy of Optometry (AAOPT)Universidade do MinhoFernandes, Paulo RodriguesNeves, HelenaFerreira, Daniela LopesJorge, JorgeGonzález-Méijome, José Manuel20132013-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/1822/27018eng1040-548810.1097/OPX.0b013e318282951b23376896info:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T11:54:14ZPortal AgregadorONG
dc.title.none.fl_str_mv Adaptation to multifocal and monovision contact lens correction
title Adaptation to multifocal and monovision contact lens correction
spellingShingle Adaptation to multifocal and monovision contact lens correction
Fernandes, Paulo Rodrigues
Monovision
Multifocal contact lenses
LogMAR visual acuity
Stereoacuity
Subjective comfort and ability
Science & Technology
title_short Adaptation to multifocal and monovision contact lens correction
title_full Adaptation to multifocal and monovision contact lens correction
title_fullStr Adaptation to multifocal and monovision contact lens correction
title_full_unstemmed Adaptation to multifocal and monovision contact lens correction
title_sort Adaptation to multifocal and monovision contact lens correction
author Fernandes, Paulo Rodrigues
author_facet Fernandes, Paulo Rodrigues
Neves, Helena
Ferreira, Daniela Lopes
Jorge, Jorge
González-Méijome, José Manuel
author_role author
author2 Neves, Helena
Ferreira, Daniela Lopes
Jorge, Jorge
González-Méijome, José Manuel
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade do Minho
dc.contributor.author.fl_str_mv Fernandes, Paulo Rodrigues
Neves, Helena
Ferreira, Daniela Lopes
Jorge, Jorge
González-Méijome, José Manuel
dc.subject.por.fl_str_mv Monovision
Multifocal contact lenses
LogMAR visual acuity
Stereoacuity
Subjective comfort and ability
Science & Technology
topic Monovision
Multifocal contact lenses
LogMAR visual acuity
Stereoacuity
Subjective comfort and ability
Science & Technology
description Purpose. To compare visual performance with the Biofinity multifocal (MF) contact lens with monovision (MV) with the Biofinity single-vision contact lens. Methods. A crossover study of 20 presbyopic patients was conducted. Patients were randomized first into either an MF or an MV lens for 15 days for each modality, with a washout period between each lens type. Measurements included monocular and binocular high- and low-contrast logarithm of the minimum angle of resolution visual acuity (VA) at distance and near visions, binocular distance contrast sensitivity function, and near stereoacuity. Results. At 15 days, patients lost fewer than two letters (half a line of VA) of binocular distance and near VA, with the MF and MV lens under high- and low-contrast conditions (P 9 0.05 for both comparisons). No statistically significant differences were seen in binocular VA at near or distance with either lens. However, the monocular distance VA improved significantly in the nondominant eye, with the MF lens by one line over the 15-day period under high-contrast (P = 0.023) and lowcontrast (P = 0.035) conditions; this effect was not seen with the MV lens. Contrast sensitivity function was within the normal limits with both lenses. The stereoacuity was significantly (P G 0.01) better with MF than with MV. Conclusions. Multifocal contact lens correction provided satisfactory levels of VA comparable with MV without compromising stereoacuity in this crossover study. The near vision significantly improved in the dominant eye, and the distance vision improved in the nondominant eye from 1 to 15 days with the MF lens, suggesting that patients adapted to the multifocality overtime, whereas this was not true for MV. (Optom Vis Sci 2013;90:228Y235)
publishDate 2013
dc.date.none.fl_str_mv 2013
2013-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/27018
url http://hdl.handle.net/1822/27018
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 1040-5488
10.1097/OPX.0b013e318282951b
23376896
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv American Academy of Optometry (AAOPT)
publisher.none.fl_str_mv American Academy of Optometry (AAOPT)
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv
repository.mail.fl_str_mv
_version_ 1777303639732256768