Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltages
Autor(a) principal: | |
---|---|
Data de Publicação: | 2014 |
Outros Autores: | , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
Texto Completo: | http://hdl.handle.net/10400.21/4859 |
Resumo: | This paper deals with the computing simulation of the impact on permanent magnet synchronous generator wind turbines due to fifth harmonic content and grid voltage decrease. Power converter topologies considered in the simulations are the two-level and the three-level ones. The three-level converters are limited by unbalance voltages in the DC-link capacitors. In order to lessen this limitation, a new control strategy for the selection of the output voltage vectors is proposed. Controller strategies considered in the simulation are respectively based on proportional integral and fractional-order controllers. Finally, a comparison between the results of the simulations with the two controller strategies is presented in order to show the main advantage of the proposed strategy. (C) 2014 Elsevier Ltd. All rights reserved. |
id |
RCAP_edfde9be708c6677c0fdeaa6088863a2 |
---|---|
oai_identifier_str |
oai:repositorio.ipl.pt:10400.21/4859 |
network_acronym_str |
RCAP |
network_name_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository_id_str |
7160 |
spelling |
Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltagesWind TurbinesPermanent Magnet GeneratorUnbalance VoltageFractional-Order ControllerElectric GridPower QualityHarmonic BehaviourThis paper deals with the computing simulation of the impact on permanent magnet synchronous generator wind turbines due to fifth harmonic content and grid voltage decrease. Power converter topologies considered in the simulations are the two-level and the three-level ones. The three-level converters are limited by unbalance voltages in the DC-link capacitors. In order to lessen this limitation, a new control strategy for the selection of the output voltage vectors is proposed. Controller strategies considered in the simulation are respectively based on proportional integral and fractional-order controllers. Finally, a comparison between the results of the simulations with the two controller strategies is presented in order to show the main advantage of the proposed strategy. (C) 2014 Elsevier Ltd. All rights reserved.Pergamon-Elsevier Science LTDRCIPLSeixas, MafaldaMelício, RuiMendes, Victor2015-08-19T13:46:06Z2014-032014-03-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articleapplication/pdfhttp://hdl.handle.net/10400.21/4859eng0196-890410.1016/j.enconman.2013.12.067metadata only accessinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-08-03T09:47:27Zoai:repositorio.ipl.pt:10400.21/4859Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T20:14:13.778533Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse |
dc.title.none.fl_str_mv |
Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltages |
title |
Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltages |
spellingShingle |
Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltages Seixas, Mafalda Wind Turbines Permanent Magnet Generator Unbalance Voltage Fractional-Order Controller Electric Grid Power Quality Harmonic Behaviour |
title_short |
Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltages |
title_full |
Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltages |
title_fullStr |
Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltages |
title_full_unstemmed |
Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltages |
title_sort |
Fifth harmonic and sag impact on PMSG wind turbines with a balancing new strategy for capacitor voltages |
author |
Seixas, Mafalda |
author_facet |
Seixas, Mafalda Melício, Rui Mendes, Victor |
author_role |
author |
author2 |
Melício, Rui Mendes, Victor |
author2_role |
author author |
dc.contributor.none.fl_str_mv |
RCIPL |
dc.contributor.author.fl_str_mv |
Seixas, Mafalda Melício, Rui Mendes, Victor |
dc.subject.por.fl_str_mv |
Wind Turbines Permanent Magnet Generator Unbalance Voltage Fractional-Order Controller Electric Grid Power Quality Harmonic Behaviour |
topic |
Wind Turbines Permanent Magnet Generator Unbalance Voltage Fractional-Order Controller Electric Grid Power Quality Harmonic Behaviour |
description |
This paper deals with the computing simulation of the impact on permanent magnet synchronous generator wind turbines due to fifth harmonic content and grid voltage decrease. Power converter topologies considered in the simulations are the two-level and the three-level ones. The three-level converters are limited by unbalance voltages in the DC-link capacitors. In order to lessen this limitation, a new control strategy for the selection of the output voltage vectors is proposed. Controller strategies considered in the simulation are respectively based on proportional integral and fractional-order controllers. Finally, a comparison between the results of the simulations with the two controller strategies is presented in order to show the main advantage of the proposed strategy. (C) 2014 Elsevier Ltd. All rights reserved. |
publishDate |
2014 |
dc.date.none.fl_str_mv |
2014-03 2014-03-01T00:00:00Z 2015-08-19T13:46:06Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://hdl.handle.net/10400.21/4859 |
url |
http://hdl.handle.net/10400.21/4859 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
0196-8904 10.1016/j.enconman.2013.12.067 |
dc.rights.driver.fl_str_mv |
metadata only access info:eu-repo/semantics/openAccess |
rights_invalid_str_mv |
metadata only access |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
application/pdf |
dc.publisher.none.fl_str_mv |
Pergamon-Elsevier Science LTD |
publisher.none.fl_str_mv |
Pergamon-Elsevier Science LTD |
dc.source.none.fl_str_mv |
reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação instacron:RCAAP |
instname_str |
Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
instacron_str |
RCAAP |
institution |
RCAAP |
reponame_str |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
collection |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) |
repository.name.fl_str_mv |
Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação |
repository.mail.fl_str_mv |
|
_version_ |
1799133399687888896 |