Dispositivo mecatrónico para a quantificação da Espasticidade

Detalhes bibliográficos
Autor(a) principal: Ferreira, João Fernandes
Data de Publicação: 2011
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
Texto Completo: http://hdl.handle.net/1822/20276
Resumo: Dissertação de mestrado integrado em Engenharia Biomédica
id RCAP_f39713cbbf1721aa456b364ea9e1938b
oai_identifier_str oai:repositorium.sdum.uminho.pt:1822/20276
network_acronym_str RCAP
network_name_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository_id_str 7160
spelling Dispositivo mecatrónico para a quantificação da Espasticidade616-073616.89-008.43Dissertação de mestrado integrado em Engenharia BiomédicaA Espasticidade é um distúrbio motor incapacitante, resultante de doenças neurológicas, conduzindo a perdas funcionais, distúrbios posturais e dor. Este distúrbio representa actualmente um grande impacto social e económico, estima-se que afecta aproximadamente 1.9% da população mundial. Regista-se um interesse clínico crescente no desenvolvimento de um método de quantificação objectiva, sensível e reprodutível, em contraste com a subjectividade do método de avaliação actualmente utilizado. Esta quantificação assume importância tanto para diagnóstico, permitindo prevenir sequelas potencialmente catastróficas, como para controlo da resposta à terapia instituída, permitindo controlar o sucesso do tratamento, assim como os onerosos custos associados. Nesta dissertação pretende-se desenvolver e implementar um equipamento para uma quantificação objectivo, sensível e reprodutível da Espasticidade, capaz de diferenciar a Espasticidade de outros distúrbios motores. É proposto um método com base na quantificação do limiar do reflexo de estiramento tónico (LRET) permitindo a avaliação da gama de movimentos do membro afectado pela Espasticidade. Inerentemente à metodologia proposta foram desenvolvidos e implementados a instrumentação e software adequados para aquisição dos sinais de Electromiografia de superfície (EMGs), trajectória e velocidade angular, e para o processamento dos sinais de modo a obter todos os dados e resultados finais. Em particular, foi desenvolvido e implementado um algoritmo inovador, para processamento de sinal de EMG, sensível e estável, para identificação de contracções musculares. Para validação do equipamento desenvolvido, foram efectuados ensaios experimentais, considerando os músculos flexores do cotovelo, que se dividiram em duas fases: numa primeira fase, em ambiente laboratorial, com indivíduos saudáveis, e numa segunda fase, em ambiente clínico, com a colaboração de pacientes com Espasticidade. Os ensaios experimentais permitiram confirmar a sensibilidade, fiabilidade e reprodutibilidade do equipamento e software, para além de ser possível observar a correlação entre o LRET identificado em três avaliações diferentes.Spasticity is a disabling motor disorder resulting from neurological diseases, leading to functional loss, postural disorders and pain. This disorder has now a remarkable social and economic impact, affecting approximately 1.9% of the world population. There is a growing clinical interest in the development of an objective, sensitive and reproducible method for Spasticity quantification, in contrast with the subjectivity of the current method. The quantification of Spasticity has a remarkable importance for diagnosis, allowing preventing catastrophic consequences, and for the applied therapy, allowing controlling the success of the treatment and the associated costs. The aim of this dissertation is to develop and implement a device for an objective, sensitive and reproducible quantification of Spasticity, able to differentiate Spaticity from other motor disorder. The proposed method is based on the quantification of the tonic stretch reflex threshold (TSRT), for the assessment of the range of motion, of the limb, affected by Spasticity. It was developed and implemented the appropriate instrumentation and software for the acquisition of sEMG signal, angular trajectory and velocity and for signal processing data. In particular, it was developed and implemented an innovative algorithm for EMG signal processing, sensitive and stable for the identification of muscle contraction. In order to validate the developed device, experimental trials have been conducted, considering the flexor muscle of the elbow joint: first, tests were performed in laboratory environment with healthy subjects; secondly, tests were run in clinical environment with the collaboration of patients with Spasticity. The experimental trials allow confirming the sensibility, reproducibility and reliability of the device and software, as well as to observe the correlation between TSRT, estimated in three different assessments.Oliveira, FilomenaMachado, José MendesMoreira, VitorUniversidade do MinhoFerreira, João Fernandes20112011-01-01T00:00:00Zinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisapplication/pdfhttp://hdl.handle.net/1822/20276porinfo:eu-repo/semantics/openAccessreponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãoinstacron:RCAAP2023-07-21T12:06:32Zoai:repositorium.sdum.uminho.pt:1822/20276Portal AgregadorONGhttps://www.rcaap.pt/oai/openaireopendoar:71602024-03-19T18:57:13.805986Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informaçãofalse
dc.title.none.fl_str_mv Dispositivo mecatrónico para a quantificação da Espasticidade
title Dispositivo mecatrónico para a quantificação da Espasticidade
spellingShingle Dispositivo mecatrónico para a quantificação da Espasticidade
Ferreira, João Fernandes
616-073
616.89-008.43
title_short Dispositivo mecatrónico para a quantificação da Espasticidade
title_full Dispositivo mecatrónico para a quantificação da Espasticidade
title_fullStr Dispositivo mecatrónico para a quantificação da Espasticidade
title_full_unstemmed Dispositivo mecatrónico para a quantificação da Espasticidade
title_sort Dispositivo mecatrónico para a quantificação da Espasticidade
author Ferreira, João Fernandes
author_facet Ferreira, João Fernandes
author_role author
dc.contributor.none.fl_str_mv Oliveira, Filomena
Machado, José Mendes
Moreira, Vitor
Universidade do Minho
dc.contributor.author.fl_str_mv Ferreira, João Fernandes
dc.subject.por.fl_str_mv 616-073
616.89-008.43
topic 616-073
616.89-008.43
description Dissertação de mestrado integrado em Engenharia Biomédica
publishDate 2011
dc.date.none.fl_str_mv 2011
2011-01-01T00:00:00Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://hdl.handle.net/1822/20276
url http://hdl.handle.net/1822/20276
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.source.none.fl_str_mv reponame:Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
instname:Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron:RCAAP
instname_str Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
instacron_str RCAAP
institution RCAAP
reponame_str Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
collection Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos)
repository.name.fl_str_mv Repositório Científico de Acesso Aberto de Portugal (Repositórios Cientìficos) - Agência para a Sociedade do Conhecimento (UMIC) - FCT - Sociedade da Informação
repository.mail.fl_str_mv
_version_ 1799132360974794752