Atrioventricular pacemaker. Incidence and causes of reprogramming in long-term follow-up

Detalhes bibliográficos
Autor(a) principal: Martinelli Fº,Martino
Data de Publicação: 2001
Outros Autores: Melo,Sylton de Arruda, Nishióka,Silvana A. D., Pedrosa,Anísio A. A., Siqueira,Sérgio Freitas de, Costa,Roberto, Sosa,Eduardo
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos Brasileiros de Cardiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2001000100002
Resumo: OBJECTIVE: To assess the incidence of problems requiring reprogramming of atrioventricular pacemakers in a long-term follow-up, and also the causes for this procedure. METHODS: During the period from May '98 to December '99, 657 patients were retrospectively studied, An actuarial curve for the event reprogramming of the stimulation mode was drawn. RESULTS: The follow-up period ranged from 12 to 178 months (mean = 81 months). Eighty-two (12.4%) patients underwent reprogramming of the stimulation mode as follows: 63 (9.5%) changed to VVI,(R/C); 10 (1.5%) changed to DVI,C; 6 (0.9%) changed to VDD,C; and 3 (0.5%) changed to DOO. The causes for the reprogramming were as follows: arrhythmia conducted by the pacemaker in 39 (37.6%) patients; loss of atrial sensitivity or capture, or both, in 39 (38.6%) patients; and microfracture of atrial electrode in 5 (4.9%) patients. The stimulation mode reprogramming free probability after 15 years was 58%. CONCLUSION: In a long-term follow-up, the atrioventricular pacemaker provided a low incidence of complications, a high probability of permanence in the DDD,C mode, and the most common cause of reprogramming was arrhythmia conducted by the pacemaker.
id SBC-1_2c3c47ad1776533051c31d4fc9b1958c
oai_identifier_str oai:scielo:S0066-782X2001000100002
network_acronym_str SBC-1
network_name_str Arquivos Brasileiros de Cardiologia (Online)
repository_id_str
spelling Atrioventricular pacemaker. Incidence and causes of reprogramming in long-term follow-upatrioventricular pacemakerreprogrammingDDD,CmodeOBJECTIVE: To assess the incidence of problems requiring reprogramming of atrioventricular pacemakers in a long-term follow-up, and also the causes for this procedure. METHODS: During the period from May '98 to December '99, 657 patients were retrospectively studied, An actuarial curve for the event reprogramming of the stimulation mode was drawn. RESULTS: The follow-up period ranged from 12 to 178 months (mean = 81 months). Eighty-two (12.4%) patients underwent reprogramming of the stimulation mode as follows: 63 (9.5%) changed to VVI,(R/C); 10 (1.5%) changed to DVI,C; 6 (0.9%) changed to VDD,C; and 3 (0.5%) changed to DOO. The causes for the reprogramming were as follows: arrhythmia conducted by the pacemaker in 39 (37.6%) patients; loss of atrial sensitivity or capture, or both, in 39 (38.6%) patients; and microfracture of atrial electrode in 5 (4.9%) patients. The stimulation mode reprogramming free probability after 15 years was 58%. CONCLUSION: In a long-term follow-up, the atrioventricular pacemaker provided a low incidence of complications, a high probability of permanence in the DDD,C mode, and the most common cause of reprogramming was arrhythmia conducted by the pacemaker.Sociedade Brasileira de Cardiologia - SBC2001-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2001000100002Arquivos Brasileiros de Cardiologia v.76 n.1 2001reponame:Arquivos Brasileiros de Cardiologia (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.1590/S0066-782X2001000100002info:eu-repo/semantics/openAccessMartinelli Fº,MartinoMelo,Sylton de ArrudaNishióka,Silvana A. D.Pedrosa,Anísio A. A.Siqueira,Sérgio Freitas deCosta,RobertoSosa,Eduardoeng2001-02-02T00:00:00Zoai:scielo:S0066-782X2001000100002Revistahttp://www.arquivosonline.com.br/https://old.scielo.br/oai/scielo-oai.php||arquivos@cardiol.br1678-41700066-782Xopendoar:2001-02-02T00:00Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)false
dc.title.none.fl_str_mv Atrioventricular pacemaker. Incidence and causes of reprogramming in long-term follow-up
title Atrioventricular pacemaker. Incidence and causes of reprogramming in long-term follow-up
spellingShingle Atrioventricular pacemaker. Incidence and causes of reprogramming in long-term follow-up
Martinelli Fº,Martino
atrioventricular pacemaker
reprogramming
DDD,Cmode
title_short Atrioventricular pacemaker. Incidence and causes of reprogramming in long-term follow-up
title_full Atrioventricular pacemaker. Incidence and causes of reprogramming in long-term follow-up
title_fullStr Atrioventricular pacemaker. Incidence and causes of reprogramming in long-term follow-up
title_full_unstemmed Atrioventricular pacemaker. Incidence and causes of reprogramming in long-term follow-up
title_sort Atrioventricular pacemaker. Incidence and causes of reprogramming in long-term follow-up
author Martinelli Fº,Martino
author_facet Martinelli Fº,Martino
Melo,Sylton de Arruda
Nishióka,Silvana A. D.
Pedrosa,Anísio A. A.
Siqueira,Sérgio Freitas de
Costa,Roberto
Sosa,Eduardo
author_role author
author2 Melo,Sylton de Arruda
Nishióka,Silvana A. D.
Pedrosa,Anísio A. A.
Siqueira,Sérgio Freitas de
Costa,Roberto
Sosa,Eduardo
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Martinelli Fº,Martino
Melo,Sylton de Arruda
Nishióka,Silvana A. D.
Pedrosa,Anísio A. A.
Siqueira,Sérgio Freitas de
Costa,Roberto
Sosa,Eduardo
dc.subject.por.fl_str_mv atrioventricular pacemaker
reprogramming
DDD,Cmode
topic atrioventricular pacemaker
reprogramming
DDD,Cmode
description OBJECTIVE: To assess the incidence of problems requiring reprogramming of atrioventricular pacemakers in a long-term follow-up, and also the causes for this procedure. METHODS: During the period from May '98 to December '99, 657 patients were retrospectively studied, An actuarial curve for the event reprogramming of the stimulation mode was drawn. RESULTS: The follow-up period ranged from 12 to 178 months (mean = 81 months). Eighty-two (12.4%) patients underwent reprogramming of the stimulation mode as follows: 63 (9.5%) changed to VVI,(R/C); 10 (1.5%) changed to DVI,C; 6 (0.9%) changed to VDD,C; and 3 (0.5%) changed to DOO. The causes for the reprogramming were as follows: arrhythmia conducted by the pacemaker in 39 (37.6%) patients; loss of atrial sensitivity or capture, or both, in 39 (38.6%) patients; and microfracture of atrial electrode in 5 (4.9%) patients. The stimulation mode reprogramming free probability after 15 years was 58%. CONCLUSION: In a long-term follow-up, the atrioventricular pacemaker provided a low incidence of complications, a high probability of permanence in the DDD,C mode, and the most common cause of reprogramming was arrhythmia conducted by the pacemaker.
publishDate 2001
dc.date.none.fl_str_mv 2001-01-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2001000100002
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2001000100002
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0066-782X2001000100002
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
dc.source.none.fl_str_mv Arquivos Brasileiros de Cardiologia v.76 n.1 2001
reponame:Arquivos Brasileiros de Cardiologia (Online)
instname:Sociedade Brasileira de Cardiologia (SBC)
instacron:SBC
instname_str Sociedade Brasileira de Cardiologia (SBC)
instacron_str SBC
institution SBC
reponame_str Arquivos Brasileiros de Cardiologia (Online)
collection Arquivos Brasileiros de Cardiologia (Online)
repository.name.fl_str_mv Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)
repository.mail.fl_str_mv ||arquivos@cardiol.br
_version_ 1752126551590174720