Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White Pattern

Detalhes bibliográficos
Autor(a) principal: Teixeira,Carlos Manuel
Data de Publicação: 2016
Outros Autores: Pereira,Telmo António, Lebreiro,Ana Margarida, Carvalho,Sérgio Alexandre
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivos Brasileiros de Cardiologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2016004300331
Resumo: Abstract Background: There are currently several electrocardiographic algorithms to locate the accessory pathway (AP) in patients with Wolff-Parkinson-White (WPW) syndrome. Objective: To compare the ability of electrocardiographic algorithms in identifying the location of the AP in patients with WPW pattern referred for ablation. Methods: Observational, cross-sectional, retrospective study with 111 patients with WPW syndrome referred for AP ablation. The electrocardiogram (ECG) obtained prior to the ablation was analyzed by an experienced observer who consecutively applied seven algorithms to identify non-invasively the AP. We then compared the location estimated with this assessment with that obtained in the electrophysiological study and calculated the agreement rates. Results: Among the APs, 59 (53.15%) were distributed around the mitral annulus and the remaining 52 (46.85%) were located around the tricuspid annulus. The overall absolute accuracy of the algorithms evaluated varied between 27% and 47%, increasing to between 40% and 76% when we included adjacent locations. The absolute agreement rate by AP location was 2.00-52.20% for septal APs (n = 51), increasing to 5.90-90.20% when considering adjacent locations; 7.70-69.20% for right APs (n = 13), increasing to 42.90-100% when considering adjacent locations; and 21.70-54.50% for left APs (n = 47), increasing to 50-87% when considering adjacent locations. Conclusion: The agreement rates observed for the analyzed scores indicated a low discriminative ability of the ECG in locating the AP in patients with WPW.
id SBC-1_67224c07aa95a81084269e646f8495a9
oai_identifier_str oai:scielo:S0066-782X2016004300331
network_acronym_str SBC-1
network_name_str Arquivos Brasileiros de Cardiologia (Online)
repository_id_str
spelling Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White PatternElectrocardiographyWolff-Parkinson-White SyndromeCatheter AblationAccessory Atrioventricular BundleData AccuracyAbstract Background: There are currently several electrocardiographic algorithms to locate the accessory pathway (AP) in patients with Wolff-Parkinson-White (WPW) syndrome. Objective: To compare the ability of electrocardiographic algorithms in identifying the location of the AP in patients with WPW pattern referred for ablation. Methods: Observational, cross-sectional, retrospective study with 111 patients with WPW syndrome referred for AP ablation. The electrocardiogram (ECG) obtained prior to the ablation was analyzed by an experienced observer who consecutively applied seven algorithms to identify non-invasively the AP. We then compared the location estimated with this assessment with that obtained in the electrophysiological study and calculated the agreement rates. Results: Among the APs, 59 (53.15%) were distributed around the mitral annulus and the remaining 52 (46.85%) were located around the tricuspid annulus. The overall absolute accuracy of the algorithms evaluated varied between 27% and 47%, increasing to between 40% and 76% when we included adjacent locations. The absolute agreement rate by AP location was 2.00-52.20% for septal APs (n = 51), increasing to 5.90-90.20% when considering adjacent locations; 7.70-69.20% for right APs (n = 13), increasing to 42.90-100% when considering adjacent locations; and 21.70-54.50% for left APs (n = 47), increasing to 50-87% when considering adjacent locations. Conclusion: The agreement rates observed for the analyzed scores indicated a low discriminative ability of the ECG in locating the AP in patients with WPW.Sociedade Brasileira de Cardiologia - SBC2016-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2016004300331Arquivos Brasileiros de Cardiologia v.107 n.4 2016reponame:Arquivos Brasileiros de Cardiologia (Online)instname:Sociedade Brasileira de Cardiologia (SBC)instacron:SBC10.5935/abc.20160132info:eu-repo/semantics/openAccessTeixeira,Carlos ManuelPereira,Telmo AntónioLebreiro,Ana MargaridaCarvalho,Sérgio Alexandreeng2016-11-09T00:00:00Zoai:scielo:S0066-782X2016004300331Revistahttp://www.arquivosonline.com.br/https://old.scielo.br/oai/scielo-oai.php||arquivos@cardiol.br1678-41700066-782Xopendoar:2016-11-09T00:00Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)false
dc.title.none.fl_str_mv Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White Pattern
title Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White Pattern
spellingShingle Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White Pattern
Teixeira,Carlos Manuel
Electrocardiography
Wolff-Parkinson-White Syndrome
Catheter Ablation
Accessory Atrioventricular Bundle
Data Accuracy
title_short Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White Pattern
title_full Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White Pattern
title_fullStr Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White Pattern
title_full_unstemmed Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White Pattern
title_sort Accuracy of the Electrocardiogram in Localizing the Accessory Pathway in Patients with Wolff-Parkinson-White Pattern
author Teixeira,Carlos Manuel
author_facet Teixeira,Carlos Manuel
Pereira,Telmo António
Lebreiro,Ana Margarida
Carvalho,Sérgio Alexandre
author_role author
author2 Pereira,Telmo António
Lebreiro,Ana Margarida
Carvalho,Sérgio Alexandre
author2_role author
author
author
dc.contributor.author.fl_str_mv Teixeira,Carlos Manuel
Pereira,Telmo António
Lebreiro,Ana Margarida
Carvalho,Sérgio Alexandre
dc.subject.por.fl_str_mv Electrocardiography
Wolff-Parkinson-White Syndrome
Catheter Ablation
Accessory Atrioventricular Bundle
Data Accuracy
topic Electrocardiography
Wolff-Parkinson-White Syndrome
Catheter Ablation
Accessory Atrioventricular Bundle
Data Accuracy
description Abstract Background: There are currently several electrocardiographic algorithms to locate the accessory pathway (AP) in patients with Wolff-Parkinson-White (WPW) syndrome. Objective: To compare the ability of electrocardiographic algorithms in identifying the location of the AP in patients with WPW pattern referred for ablation. Methods: Observational, cross-sectional, retrospective study with 111 patients with WPW syndrome referred for AP ablation. The electrocardiogram (ECG) obtained prior to the ablation was analyzed by an experienced observer who consecutively applied seven algorithms to identify non-invasively the AP. We then compared the location estimated with this assessment with that obtained in the electrophysiological study and calculated the agreement rates. Results: Among the APs, 59 (53.15%) were distributed around the mitral annulus and the remaining 52 (46.85%) were located around the tricuspid annulus. The overall absolute accuracy of the algorithms evaluated varied between 27% and 47%, increasing to between 40% and 76% when we included adjacent locations. The absolute agreement rate by AP location was 2.00-52.20% for septal APs (n = 51), increasing to 5.90-90.20% when considering adjacent locations; 7.70-69.20% for right APs (n = 13), increasing to 42.90-100% when considering adjacent locations; and 21.70-54.50% for left APs (n = 47), increasing to 50-87% when considering adjacent locations. Conclusion: The agreement rates observed for the analyzed scores indicated a low discriminative ability of the ECG in locating the AP in patients with WPW.
publishDate 2016
dc.date.none.fl_str_mv 2016-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2016004300331
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0066-782X2016004300331
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/abc.20160132
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
publisher.none.fl_str_mv Sociedade Brasileira de Cardiologia - SBC
dc.source.none.fl_str_mv Arquivos Brasileiros de Cardiologia v.107 n.4 2016
reponame:Arquivos Brasileiros de Cardiologia (Online)
instname:Sociedade Brasileira de Cardiologia (SBC)
instacron:SBC
instname_str Sociedade Brasileira de Cardiologia (SBC)
instacron_str SBC
institution SBC
reponame_str Arquivos Brasileiros de Cardiologia (Online)
collection Arquivos Brasileiros de Cardiologia (Online)
repository.name.fl_str_mv Arquivos Brasileiros de Cardiologia (Online) - Sociedade Brasileira de Cardiologia (SBC)
repository.mail.fl_str_mv ||arquivos@cardiol.br
_version_ 1752126566776700928