Correction equations to estimate body fat with plicometer WCS dual hand
Autor(a) principal: | |
---|---|
Data de Publicação: | 2017 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Research on Biomedical Engineering (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2446-47402017000400285 |
Resumo: | ABSTRACT Introduction This study aimed to propose regression equations for the correction of fat percentage values obtained with the WCS Dual Hand skinfold caliper, using the Lange skinfold caliper as a reference. Methods This study evaluated 112 undergraduate students from the Physical Education and Physical Therapy programs of the Faculdade Dom Bosco, located in Curitiba, Paraná, Brazil. Of these, 58 women were 24.9±5.8 years old and 54 men were 27.6±7.9 years old. The evaluation comprised the following measurements: height, body mass, and nine skin folds with WCS Dual Hand and Lange skinfold calipers used in biceps, triceps, subscapular, suprailiac, pectoral, average axillary, medial thigh, abdominal, and calf measurements. Results Through the simple linear regression analysis, eight equations were generated to correct the relative body fat obtained with equations commonly used in Brazil. For these correction equations, R2 was between 0.830 and 0.961 and p-value was 0.000 for all measurements. Conclusion These results indicate the use of equations for the correction of estimated values of relative body fat measured with the WCS Dual Hand skinfold caliper, whenever the Lange skinfold caliper is not available, in order to minimize the difference between them. |
id |
SBEB-1_9f61382caa1dac293ea308b0dcd451ae |
---|---|
oai_identifier_str |
oai:scielo:S2446-47402017000400285 |
network_acronym_str |
SBEB-1 |
network_name_str |
Research on Biomedical Engineering (Online) |
repository_id_str |
|
spelling |
Correction equations to estimate body fat with plicometer WCS dual handValidationSkinfold caliperBody compositionABSTRACT Introduction This study aimed to propose regression equations for the correction of fat percentage values obtained with the WCS Dual Hand skinfold caliper, using the Lange skinfold caliper as a reference. Methods This study evaluated 112 undergraduate students from the Physical Education and Physical Therapy programs of the Faculdade Dom Bosco, located in Curitiba, Paraná, Brazil. Of these, 58 women were 24.9±5.8 years old and 54 men were 27.6±7.9 years old. The evaluation comprised the following measurements: height, body mass, and nine skin folds with WCS Dual Hand and Lange skinfold calipers used in biceps, triceps, subscapular, suprailiac, pectoral, average axillary, medial thigh, abdominal, and calf measurements. Results Through the simple linear regression analysis, eight equations were generated to correct the relative body fat obtained with equations commonly used in Brazil. For these correction equations, R2 was between 0.830 and 0.961 and p-value was 0.000 for all measurements. Conclusion These results indicate the use of equations for the correction of estimated values of relative body fat measured with the WCS Dual Hand skinfold caliper, whenever the Lange skinfold caliper is not available, in order to minimize the difference between them.Sociedade Brasileira de Engenharia Biomédica2017-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S2446-47402017000400285Research on Biomedical Engineering v.33 n.4 2017reponame:Research on Biomedical Engineering (Online)instname:Sociedade Brasileira de Engenharia Biomédica (SBEB)instacron:SBEB10.1590/2446-4740.01117info:eu-repo/semantics/openAccessZonatto,Hiago AugustoRibas,Marcelo RomanovitchSimm,Eduardo BolicenhaOliveira,André Gonçalves deBassan,Julio Cesareng2018-01-09T00:00:00Zoai:scielo:S2446-47402017000400285Revistahttp://www.rbejournal.org/https://old.scielo.br/oai/scielo-oai.php||rbe@rbejournal.org2446-47402446-4732opendoar:2018-01-09T00:00Research on Biomedical Engineering (Online) - Sociedade Brasileira de Engenharia Biomédica (SBEB)false |
dc.title.none.fl_str_mv |
Correction equations to estimate body fat with plicometer WCS dual hand |
title |
Correction equations to estimate body fat with plicometer WCS dual hand |
spellingShingle |
Correction equations to estimate body fat with plicometer WCS dual hand Zonatto,Hiago Augusto Validation Skinfold caliper Body composition |
title_short |
Correction equations to estimate body fat with plicometer WCS dual hand |
title_full |
Correction equations to estimate body fat with plicometer WCS dual hand |
title_fullStr |
Correction equations to estimate body fat with plicometer WCS dual hand |
title_full_unstemmed |
Correction equations to estimate body fat with plicometer WCS dual hand |
title_sort |
Correction equations to estimate body fat with plicometer WCS dual hand |
author |
Zonatto,Hiago Augusto |
author_facet |
Zonatto,Hiago Augusto Ribas,Marcelo Romanovitch Simm,Eduardo Bolicenha Oliveira,André Gonçalves de Bassan,Julio Cesar |
author_role |
author |
author2 |
Ribas,Marcelo Romanovitch Simm,Eduardo Bolicenha Oliveira,André Gonçalves de Bassan,Julio Cesar |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Zonatto,Hiago Augusto Ribas,Marcelo Romanovitch Simm,Eduardo Bolicenha Oliveira,André Gonçalves de Bassan,Julio Cesar |
dc.subject.por.fl_str_mv |
Validation Skinfold caliper Body composition |
topic |
Validation Skinfold caliper Body composition |
description |
ABSTRACT Introduction This study aimed to propose regression equations for the correction of fat percentage values obtained with the WCS Dual Hand skinfold caliper, using the Lange skinfold caliper as a reference. Methods This study evaluated 112 undergraduate students from the Physical Education and Physical Therapy programs of the Faculdade Dom Bosco, located in Curitiba, Paraná, Brazil. Of these, 58 women were 24.9±5.8 years old and 54 men were 27.6±7.9 years old. The evaluation comprised the following measurements: height, body mass, and nine skin folds with WCS Dual Hand and Lange skinfold calipers used in biceps, triceps, subscapular, suprailiac, pectoral, average axillary, medial thigh, abdominal, and calf measurements. Results Through the simple linear regression analysis, eight equations were generated to correct the relative body fat obtained with equations commonly used in Brazil. For these correction equations, R2 was between 0.830 and 0.961 and p-value was 0.000 for all measurements. Conclusion These results indicate the use of equations for the correction of estimated values of relative body fat measured with the WCS Dual Hand skinfold caliper, whenever the Lange skinfold caliper is not available, in order to minimize the difference between them. |
publishDate |
2017 |
dc.date.none.fl_str_mv |
2017-10-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2446-47402017000400285 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S2446-47402017000400285 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/2446-4740.01117 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Engenharia Biomédica |
publisher.none.fl_str_mv |
Sociedade Brasileira de Engenharia Biomédica |
dc.source.none.fl_str_mv |
Research on Biomedical Engineering v.33 n.4 2017 reponame:Research on Biomedical Engineering (Online) instname:Sociedade Brasileira de Engenharia Biomédica (SBEB) instacron:SBEB |
instname_str |
Sociedade Brasileira de Engenharia Biomédica (SBEB) |
instacron_str |
SBEB |
institution |
SBEB |
reponame_str |
Research on Biomedical Engineering (Online) |
collection |
Research on Biomedical Engineering (Online) |
repository.name.fl_str_mv |
Research on Biomedical Engineering (Online) - Sociedade Brasileira de Engenharia Biomédica (SBEB) |
repository.mail.fl_str_mv |
||rbe@rbejournal.org |
_version_ |
1752126288761454592 |