Proton CT setup at CV-28 of IEN/CNEN

Detalhes bibliográficos
Autor(a) principal: Evseev,I.
Data de Publicação: 2005
Outros Autores: Assis,J. Teixeira de, Yevseyeva,O., Vinagre Filho,U.M., Setti,J.A.P., Schelin,H.R., Paschuk,S.A., Klock,M.C.L., Schulte,R.W., Lopes,R.T.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Journal of Physics
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332005000500006
Resumo: Although the idea of proton Computed Tomography (pCT) is not new, it is currently not available. It is still unknown if the image quality of pCT is sufficient for localizing tumors and if the accuracy of proton range calculations surpass that of X-ray CT based range calculations without significantly increasing the patient exposure. The spatial resolution of pCT is limited mainly by multiple Coulomb scattering, while the contrast resolution is affected principally by the statistical nature of the proton energy loss mechanism. Both effects are more pronounced and thus easier to study at the low proton energies available at CV-28. An experimental setup for pCT at CV-28 was elaborated by our team. The first-generation CT scheme was assumed as the most adequate for the existing CV-28 proton "pencil" beam. All equipment, which includes the collimators for the initial and outgoing proton beam, the tomographic turntable, and the ORTEC L-035-025-5 proton detector, was assembled onto the support bar of the ORTEC vacuum chamber. A water-filled glass tube of 5 mm external diameter with a 1 mm diameter polyethylene rod on the central axis was chosen as the first sample to be studied. Later, the water will be substituted by tissue-equivalent solutions of different densities to study the contrast resolution. A Monte Carlo simulation of the experiment, assuming 25 MeV monochromatic proton beam, was made using the SRIM-2003.20 code. The simulation permitted to choose the critical parameters for the setup, such as the beam collimation, the steps of translation and rotation of the turntable, and the required statistics for an accurate measurement of proton energy.
id SBF-2_8cc63c0b289f6103b72f16b23639ee12
oai_identifier_str oai:scielo:S0103-97332005000500006
network_acronym_str SBF-2
network_name_str Brazilian Journal of Physics
repository_id_str
spelling Proton CT setup at CV-28 of IEN/CNENAlthough the idea of proton Computed Tomography (pCT) is not new, it is currently not available. It is still unknown if the image quality of pCT is sufficient for localizing tumors and if the accuracy of proton range calculations surpass that of X-ray CT based range calculations without significantly increasing the patient exposure. The spatial resolution of pCT is limited mainly by multiple Coulomb scattering, while the contrast resolution is affected principally by the statistical nature of the proton energy loss mechanism. Both effects are more pronounced and thus easier to study at the low proton energies available at CV-28. An experimental setup for pCT at CV-28 was elaborated by our team. The first-generation CT scheme was assumed as the most adequate for the existing CV-28 proton "pencil" beam. All equipment, which includes the collimators for the initial and outgoing proton beam, the tomographic turntable, and the ORTEC L-035-025-5 proton detector, was assembled onto the support bar of the ORTEC vacuum chamber. A water-filled glass tube of 5 mm external diameter with a 1 mm diameter polyethylene rod on the central axis was chosen as the first sample to be studied. Later, the water will be substituted by tissue-equivalent solutions of different densities to study the contrast resolution. A Monte Carlo simulation of the experiment, assuming 25 MeV monochromatic proton beam, was made using the SRIM-2003.20 code. The simulation permitted to choose the critical parameters for the setup, such as the beam collimation, the steps of translation and rotation of the turntable, and the required statistics for an accurate measurement of proton energy.Sociedade Brasileira de Física2005-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332005000500006Brazilian Journal of Physics v.35 n.3b 2005reponame:Brazilian Journal of Physicsinstname:Sociedade Brasileira de Física (SBF)instacron:SBF10.1590/S0103-97332005000500006info:eu-repo/semantics/openAccessEvseev,I.Assis,J. Teixeira deYevseyeva,O.Vinagre Filho,U.M.Setti,J.A.P.Schelin,H.R.Paschuk,S.A.Klock,M.C.L.Schulte,R.W.Lopes,R.T.eng2005-11-07T00:00:00Zoai:scielo:S0103-97332005000500006Revistahttp://www.sbfisica.org.br/v1/home/index.php/pt/ONGhttps://old.scielo.br/oai/scielo-oai.phpsbfisica@sbfisica.org.br||sbfisica@sbfisica.org.br1678-44480103-9733opendoar:2005-11-07T00:00Brazilian Journal of Physics - Sociedade Brasileira de Física (SBF)false
dc.title.none.fl_str_mv Proton CT setup at CV-28 of IEN/CNEN
title Proton CT setup at CV-28 of IEN/CNEN
spellingShingle Proton CT setup at CV-28 of IEN/CNEN
Evseev,I.
title_short Proton CT setup at CV-28 of IEN/CNEN
title_full Proton CT setup at CV-28 of IEN/CNEN
title_fullStr Proton CT setup at CV-28 of IEN/CNEN
title_full_unstemmed Proton CT setup at CV-28 of IEN/CNEN
title_sort Proton CT setup at CV-28 of IEN/CNEN
author Evseev,I.
author_facet Evseev,I.
Assis,J. Teixeira de
Yevseyeva,O.
Vinagre Filho,U.M.
Setti,J.A.P.
Schelin,H.R.
Paschuk,S.A.
Klock,M.C.L.
Schulte,R.W.
Lopes,R.T.
author_role author
author2 Assis,J. Teixeira de
Yevseyeva,O.
Vinagre Filho,U.M.
Setti,J.A.P.
Schelin,H.R.
Paschuk,S.A.
Klock,M.C.L.
Schulte,R.W.
Lopes,R.T.
author2_role author
author
author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Evseev,I.
Assis,J. Teixeira de
Yevseyeva,O.
Vinagre Filho,U.M.
Setti,J.A.P.
Schelin,H.R.
Paschuk,S.A.
Klock,M.C.L.
Schulte,R.W.
Lopes,R.T.
description Although the idea of proton Computed Tomography (pCT) is not new, it is currently not available. It is still unknown if the image quality of pCT is sufficient for localizing tumors and if the accuracy of proton range calculations surpass that of X-ray CT based range calculations without significantly increasing the patient exposure. The spatial resolution of pCT is limited mainly by multiple Coulomb scattering, while the contrast resolution is affected principally by the statistical nature of the proton energy loss mechanism. Both effects are more pronounced and thus easier to study at the low proton energies available at CV-28. An experimental setup for pCT at CV-28 was elaborated by our team. The first-generation CT scheme was assumed as the most adequate for the existing CV-28 proton "pencil" beam. All equipment, which includes the collimators for the initial and outgoing proton beam, the tomographic turntable, and the ORTEC L-035-025-5 proton detector, was assembled onto the support bar of the ORTEC vacuum chamber. A water-filled glass tube of 5 mm external diameter with a 1 mm diameter polyethylene rod on the central axis was chosen as the first sample to be studied. Later, the water will be substituted by tissue-equivalent solutions of different densities to study the contrast resolution. A Monte Carlo simulation of the experiment, assuming 25 MeV monochromatic proton beam, was made using the SRIM-2003.20 code. The simulation permitted to choose the critical parameters for the setup, such as the beam collimation, the steps of translation and rotation of the turntable, and the required statistics for an accurate measurement of proton energy.
publishDate 2005
dc.date.none.fl_str_mv 2005-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332005000500006
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-97332005000500006
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-97332005000500006
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Física
publisher.none.fl_str_mv Sociedade Brasileira de Física
dc.source.none.fl_str_mv Brazilian Journal of Physics v.35 n.3b 2005
reponame:Brazilian Journal of Physics
instname:Sociedade Brasileira de Física (SBF)
instacron:SBF
instname_str Sociedade Brasileira de Física (SBF)
instacron_str SBF
institution SBF
reponame_str Brazilian Journal of Physics
collection Brazilian Journal of Physics
repository.name.fl_str_mv Brazilian Journal of Physics - Sociedade Brasileira de Física (SBF)
repository.mail.fl_str_mv sbfisica@sbfisica.org.br||sbfisica@sbfisica.org.br
_version_ 1754734862207549440