Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy

Detalhes bibliográficos
Autor(a) principal: Caballero,Juan Carlos Sánchez
Data de Publicação: 2013
Outros Autores: Centurion,Virgilio
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Revista Brasileira de Oftalmologia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802013000200006
Resumo: OBJECTIVE: To analyze refractive results in postoperative cataract surgery in eyes previously submitted to keratotomy using Haigis formula and data provided by IOL Master®optical biometer. METHODS: The measurements for IOL calculation were obtained through optical biometry by partial coherence interferometry (IOL Master®- Zeiss, 5.4 and 5.5 version) that provides us with the axial length, the central keratometry of 2.5mm, white-to-white diameter and anterior chamber anatomical depth. The formula chosen was Haigis. The surgical technique applied was with the scleral incision at 1.5 mm from the limbus, with scleral-corneal tunnel of 2.2 mm wide, phacoemulsification using INFINITI Ozil®- Alcon and implantation of hydrophobic acrylic aspheric intraocular lens - SN60WF®- Alcon. RESULTS: We studied 20 eyes submitted to keratotomy in the past and currently with cataract with indication for cataract surgerywith intraocular lens implantation using phacoemulsification. Postoperative spherical equivalent was plano in 40% of the eyes and lower than -1.00 in 85% of the eyes. CONCLUSION: The optical biometry by partial coherence interferometry associated with Haigis formula is a valid alternative in IOL calculation for eyes submitted to keratotomy. The refractive results are highly predictable and reproducible.
id SBO-1_9faf0631c2c7e121412012c74a4e410f
oai_identifier_str oai:scielo:S0034-72802013000200006
network_acronym_str SBO-1
network_name_str Revista Brasileira de Oftalmologia (Online)
repository_id_str
spelling Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomyIntraocular lensAnterior chamberkeratotomy, radialBiometry/instrumentationAxial length, eye/pathologyOBJECTIVE: To analyze refractive results in postoperative cataract surgery in eyes previously submitted to keratotomy using Haigis formula and data provided by IOL Master®optical biometer. METHODS: The measurements for IOL calculation were obtained through optical biometry by partial coherence interferometry (IOL Master®- Zeiss, 5.4 and 5.5 version) that provides us with the axial length, the central keratometry of 2.5mm, white-to-white diameter and anterior chamber anatomical depth. The formula chosen was Haigis. The surgical technique applied was with the scleral incision at 1.5 mm from the limbus, with scleral-corneal tunnel of 2.2 mm wide, phacoemulsification using INFINITI Ozil®- Alcon and implantation of hydrophobic acrylic aspheric intraocular lens - SN60WF®- Alcon. RESULTS: We studied 20 eyes submitted to keratotomy in the past and currently with cataract with indication for cataract surgerywith intraocular lens implantation using phacoemulsification. Postoperative spherical equivalent was plano in 40% of the eyes and lower than -1.00 in 85% of the eyes. CONCLUSION: The optical biometry by partial coherence interferometry associated with Haigis formula is a valid alternative in IOL calculation for eyes submitted to keratotomy. The refractive results are highly predictable and reproducible.Sociedade Brasileira de Oftalmologia2013-04-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802013000200006Revista Brasileira de Oftalmologia v.72 n.2 2013reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBO10.1590/S0034-72802013000200006info:eu-repo/semantics/openAccessCaballero,Juan Carlos SánchezCenturion,Virgilioeng2013-06-28T00:00:00Zoai:scielo:S0034-72802013000200006Revistahttps://rbo.emnuvens.com.br/rbo/indexhttps://old.scielo.br/oai/scielo-oai.phpsob@sboportal.org.br||rbo@sboportal.org.br1982-85510034-7280opendoar:2013-06-28T00:00Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)false
dc.title.none.fl_str_mv Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy
title Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy
spellingShingle Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy
Caballero,Juan Carlos Sánchez
Intraocular lens
Anterior chamber
keratotomy, radial
Biometry/instrumentation
Axial length, eye/pathology
title_short Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy
title_full Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy
title_fullStr Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy
title_full_unstemmed Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy
title_sort Refractive results of cataract surgery using optical biometry and Haigis formula in eyes with refractive keratotomy
author Caballero,Juan Carlos Sánchez
author_facet Caballero,Juan Carlos Sánchez
Centurion,Virgilio
author_role author
author2 Centurion,Virgilio
author2_role author
dc.contributor.author.fl_str_mv Caballero,Juan Carlos Sánchez
Centurion,Virgilio
dc.subject.por.fl_str_mv Intraocular lens
Anterior chamber
keratotomy, radial
Biometry/instrumentation
Axial length, eye/pathology
topic Intraocular lens
Anterior chamber
keratotomy, radial
Biometry/instrumentation
Axial length, eye/pathology
description OBJECTIVE: To analyze refractive results in postoperative cataract surgery in eyes previously submitted to keratotomy using Haigis formula and data provided by IOL Master®optical biometer. METHODS: The measurements for IOL calculation were obtained through optical biometry by partial coherence interferometry (IOL Master®- Zeiss, 5.4 and 5.5 version) that provides us with the axial length, the central keratometry of 2.5mm, white-to-white diameter and anterior chamber anatomical depth. The formula chosen was Haigis. The surgical technique applied was with the scleral incision at 1.5 mm from the limbus, with scleral-corneal tunnel of 2.2 mm wide, phacoemulsification using INFINITI Ozil®- Alcon and implantation of hydrophobic acrylic aspheric intraocular lens - SN60WF®- Alcon. RESULTS: We studied 20 eyes submitted to keratotomy in the past and currently with cataract with indication for cataract surgerywith intraocular lens implantation using phacoemulsification. Postoperative spherical equivalent was plano in 40% of the eyes and lower than -1.00 in 85% of the eyes. CONCLUSION: The optical biometry by partial coherence interferometry associated with Haigis formula is a valid alternative in IOL calculation for eyes submitted to keratotomy. The refractive results are highly predictable and reproducible.
publishDate 2013
dc.date.none.fl_str_mv 2013-04-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802013000200006
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802013000200006
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0034-72802013000200006
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
publisher.none.fl_str_mv Sociedade Brasileira de Oftalmologia
dc.source.none.fl_str_mv Revista Brasileira de Oftalmologia v.72 n.2 2013
reponame:Revista Brasileira de Oftalmologia (Online)
instname:Sociedade Brasileira de Oftalmologia (SBO)
instacron:SBO
instname_str Sociedade Brasileira de Oftalmologia (SBO)
instacron_str SBO
institution SBO
reponame_str Revista Brasileira de Oftalmologia (Online)
collection Revista Brasileira de Oftalmologia (Online)
repository.name.fl_str_mv Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)
repository.mail.fl_str_mv sob@sboportal.org.br||rbo@sboportal.org.br
_version_ 1752122336478232576