Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lenses
Autor(a) principal: | |
---|---|
Data de Publicação: | 2012 |
Outros Autores: | , , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Revista Brasileira de Oftalmologia (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802012000300002 |
Resumo: | Five cases of intraocular lens (IOL) opacification in patients implanted with the Mediphacos Ioflex® IOL are described. Clinical data in each case was obtained from the patient's medical record. The five explanted IOLs underwent gross and light microscopic analysis. Selected lenses were processed for further evaluation and multiple sagittal cuts were stained with the alizarin red and von Kossa methods. Light microscope analysis confirmed the presence of deposits on and within the lens, which stained positive for calcium. The reason why calcification has occurred in these cases remains unclear, but surgeons should be aware of this potential late postoperative complication. |
id |
SBO-1_ced9bda9a91cc553d7bb44e75d464059 |
---|---|
oai_identifier_str |
oai:scielo:S0034-72802012000300002 |
network_acronym_str |
SBO-1 |
network_name_str |
Revista Brasileira de Oftalmologia (Online) |
repository_id_str |
|
spelling |
Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lensesLensesintraocularLens implantationintraocularReoperationDevice removalMicroscopyCase reportsFive cases of intraocular lens (IOL) opacification in patients implanted with the Mediphacos Ioflex® IOL are described. Clinical data in each case was obtained from the patient's medical record. The five explanted IOLs underwent gross and light microscopic analysis. Selected lenses were processed for further evaluation and multiple sagittal cuts were stained with the alizarin red and von Kossa methods. Light microscope analysis confirmed the presence of deposits on and within the lens, which stained positive for calcium. The reason why calcification has occurred in these cases remains unclear, but surgeons should be aware of this potential late postoperative complication.Sociedade Brasileira de Oftalmologia2012-06-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802012000300002Revista Brasileira de Oftalmologia v.71 n.3 2012reponame:Revista Brasileira de Oftalmologia (Online)instname:Sociedade Brasileira de Oftalmologia (SBO)instacron:SBO10.1590/S0034-72802012000300002info:eu-repo/semantics/openAccessVentura,Bruna VieiraVentura,MarceloLira,WagnerVentura,Camila VieiraSanthiago,Marcony RodriguesWerner,Lilianaeng2012-07-31T00:00:00Zoai:scielo:S0034-72802012000300002Revistahttps://rbo.emnuvens.com.br/rbo/indexhttps://old.scielo.br/oai/scielo-oai.phpsob@sboportal.org.br||rbo@sboportal.org.br1982-85510034-7280opendoar:2012-07-31T00:00Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO)false |
dc.title.none.fl_str_mv |
Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lenses |
title |
Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lenses |
spellingShingle |
Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lenses Ventura,Bruna Vieira Lenses intraocular Lens implantation intraocular Reoperation Device removal Microscopy Case reports |
title_short |
Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lenses |
title_full |
Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lenses |
title_fullStr |
Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lenses |
title_full_unstemmed |
Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lenses |
title_sort |
Microscopic analysis of opacification in Ioflex® hydrophilic acrylic intraocular lenses |
author |
Ventura,Bruna Vieira |
author_facet |
Ventura,Bruna Vieira Ventura,Marcelo Lira,Wagner Ventura,Camila Vieira Santhiago,Marcony Rodrigues Werner,Liliana |
author_role |
author |
author2 |
Ventura,Marcelo Lira,Wagner Ventura,Camila Vieira Santhiago,Marcony Rodrigues Werner,Liliana |
author2_role |
author author author author author |
dc.contributor.author.fl_str_mv |
Ventura,Bruna Vieira Ventura,Marcelo Lira,Wagner Ventura,Camila Vieira Santhiago,Marcony Rodrigues Werner,Liliana |
dc.subject.por.fl_str_mv |
Lenses intraocular Lens implantation intraocular Reoperation Device removal Microscopy Case reports |
topic |
Lenses intraocular Lens implantation intraocular Reoperation Device removal Microscopy Case reports |
description |
Five cases of intraocular lens (IOL) opacification in patients implanted with the Mediphacos Ioflex® IOL are described. Clinical data in each case was obtained from the patient's medical record. The five explanted IOLs underwent gross and light microscopic analysis. Selected lenses were processed for further evaluation and multiple sagittal cuts were stained with the alizarin red and von Kossa methods. Light microscope analysis confirmed the presence of deposits on and within the lens, which stained positive for calcium. The reason why calcification has occurred in these cases remains unclear, but surgeons should be aware of this potential late postoperative complication. |
publishDate |
2012 |
dc.date.none.fl_str_mv |
2012-06-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802012000300002 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0034-72802012000300002 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0034-72802012000300002 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Oftalmologia |
publisher.none.fl_str_mv |
Sociedade Brasileira de Oftalmologia |
dc.source.none.fl_str_mv |
Revista Brasileira de Oftalmologia v.71 n.3 2012 reponame:Revista Brasileira de Oftalmologia (Online) instname:Sociedade Brasileira de Oftalmologia (SBO) instacron:SBO |
instname_str |
Sociedade Brasileira de Oftalmologia (SBO) |
instacron_str |
SBO |
institution |
SBO |
reponame_str |
Revista Brasileira de Oftalmologia (Online) |
collection |
Revista Brasileira de Oftalmologia (Online) |
repository.name.fl_str_mv |
Revista Brasileira de Oftalmologia (Online) - Sociedade Brasileira de Oftalmologia (SBO) |
repository.mail.fl_str_mv |
sob@sboportal.org.br||rbo@sboportal.org.br |
_version_ |
1752122336060899328 |