Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments

Detalhes bibliográficos
Autor(a) principal: Lima,Emilena Maria Castor Xisto
Data de Publicação: 2006
Outros Autores: Silva,Wander José da, Moura,Juliana Silva, Faot,Fernanda, Del Bel Cury,Altair Antoninha
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242006000400005
Resumo: The aim of this study was to evaluate surface free energy (SFE), surface roughness (SR) and surface hardness (SH) of two commercially available materials for fabricating dental implant abutments. In addition, the specimens were investigated by scanning electron microscopy (SEM) to determine the surface morphology. Twenty five discs (5 x 2 mm) of Ti-6Al-4V and Tilite (Ni-Cr-Ti) alloys were used in this study. Surface free energy was determined by the contact angle formed between a drop of distilled, deionized water and the surface of the specimen of each material. The surface roughness was measured with a mechanical profilometer and the surface hardness was evaluated by means of the Vickers hardness micro indentation test. SFE, SR and SH data were analyzed using one-way ANOVA (p < 0.05). Statistical differences (p < 0.05) were found between Ti-6Al-4V (36.2 erg.cm-2; 0.2 µm) and Tilite (30.9 erg.cm-2; 0.16 µm) for SFE and SR. However, the differences between the surface hardness values of Ti-6Al-4V (325.0 kg/mm²) and Tilite (324.3 kg/mm²) were not statistically significant (p > 0.05). Evaluations by SEM revealed different surface morphology. Within the limits of this study, it can be concluded that the Ti-6Al-4V and Tilite alloys showed differences in surface properties, except for surface hardness, suggesting that both alloys may be considered appropriate for producing abutments. Further studies are, however, necessary to elucidate the biological responses to implant abutments made with these alloys.
id SBPQO-1_145032716fcd56be231a2ec37550f735
oai_identifier_str oai:scielo:S1806-83242006000400005
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutmentsSurface propertiesDental implantsTitaniumThe aim of this study was to evaluate surface free energy (SFE), surface roughness (SR) and surface hardness (SH) of two commercially available materials for fabricating dental implant abutments. In addition, the specimens were investigated by scanning electron microscopy (SEM) to determine the surface morphology. Twenty five discs (5 x 2 mm) of Ti-6Al-4V and Tilite (Ni-Cr-Ti) alloys were used in this study. Surface free energy was determined by the contact angle formed between a drop of distilled, deionized water and the surface of the specimen of each material. The surface roughness was measured with a mechanical profilometer and the surface hardness was evaluated by means of the Vickers hardness micro indentation test. SFE, SR and SH data were analyzed using one-way ANOVA (p < 0.05). Statistical differences (p < 0.05) were found between Ti-6Al-4V (36.2 erg.cm-2; 0.2 µm) and Tilite (30.9 erg.cm-2; 0.16 µm) for SFE and SR. However, the differences between the surface hardness values of Ti-6Al-4V (325.0 kg/mm²) and Tilite (324.3 kg/mm²) were not statistically significant (p > 0.05). Evaluations by SEM revealed different surface morphology. Within the limits of this study, it can be concluded that the Ti-6Al-4V and Tilite alloys showed differences in surface properties, except for surface hardness, suggesting that both alloys may be considered appropriate for producing abutments. Further studies are, however, necessary to elucidate the biological responses to implant abutments made with these alloys.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2006-12-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242006000400005Brazilian Oral Research v.20 n.4 2006reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242006000400005info:eu-repo/semantics/openAccessLima,Emilena Maria Castor XistoSilva,Wander José daMoura,Juliana SilvaFaot,FernandaDel Bel Cury,Altair Antoninhaeng2007-01-18T00:00:00Zoai:scielo:S1806-83242006000400005Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2007-01-18T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments
title Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments
spellingShingle Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments
Lima,Emilena Maria Castor Xisto
Surface properties
Dental implants
Titanium
title_short Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments
title_full Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments
title_fullStr Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments
title_full_unstemmed Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments
title_sort Evaluation of surface characteristics of Ti-6Al-4V and Tilite alloys used for implant abutments
author Lima,Emilena Maria Castor Xisto
author_facet Lima,Emilena Maria Castor Xisto
Silva,Wander José da
Moura,Juliana Silva
Faot,Fernanda
Del Bel Cury,Altair Antoninha
author_role author
author2 Silva,Wander José da
Moura,Juliana Silva
Faot,Fernanda
Del Bel Cury,Altair Antoninha
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Lima,Emilena Maria Castor Xisto
Silva,Wander José da
Moura,Juliana Silva
Faot,Fernanda
Del Bel Cury,Altair Antoninha
dc.subject.por.fl_str_mv Surface properties
Dental implants
Titanium
topic Surface properties
Dental implants
Titanium
description The aim of this study was to evaluate surface free energy (SFE), surface roughness (SR) and surface hardness (SH) of two commercially available materials for fabricating dental implant abutments. In addition, the specimens were investigated by scanning electron microscopy (SEM) to determine the surface morphology. Twenty five discs (5 x 2 mm) of Ti-6Al-4V and Tilite (Ni-Cr-Ti) alloys were used in this study. Surface free energy was determined by the contact angle formed between a drop of distilled, deionized water and the surface of the specimen of each material. The surface roughness was measured with a mechanical profilometer and the surface hardness was evaluated by means of the Vickers hardness micro indentation test. SFE, SR and SH data were analyzed using one-way ANOVA (p < 0.05). Statistical differences (p < 0.05) were found between Ti-6Al-4V (36.2 erg.cm-2; 0.2 µm) and Tilite (30.9 erg.cm-2; 0.16 µm) for SFE and SR. However, the differences between the surface hardness values of Ti-6Al-4V (325.0 kg/mm²) and Tilite (324.3 kg/mm²) were not statistically significant (p > 0.05). Evaluations by SEM revealed different surface morphology. Within the limits of this study, it can be concluded that the Ti-6Al-4V and Tilite alloys showed differences in surface properties, except for surface hardness, suggesting that both alloys may be considered appropriate for producing abutments. Further studies are, however, necessary to elucidate the biological responses to implant abutments made with these alloys.
publishDate 2006
dc.date.none.fl_str_mv 2006-12-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242006000400005
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242006000400005
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242006000400005
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.20 n.4 2006
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318320795516928