Effect of the diameter on Cu-Al post retention
Autor(a) principal: | |
---|---|
Data de Publicação: | 2004 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Brazilian Oral Research |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300011 |
Resumo: | This study compared the resistance to removal by traction of abraded cylindrical metal cast posts of Cu-Al (Goldent-LA). The posts had constant length (9 mm) and three different diameters (0.9, 1.3 and 1.7 mm), and were cemented with zinc phosphate cement. The crowns of 36 sound maxillary canines were sectioned, the roots were immersed in resin blocks and the root canals were endodontically treated. The teeth were divided into three groups to be prepared and standardized with the use of a parallelometer with the following burs: Group 1 - Largo n. 2; Group 2 - Largo n. 4; Group 3 - Largo n. 6. The posts were molded with chemically activated resin and after casting they were abraded and their dimensions were confirmed with a digital caliper. After cementation of the posts in the prepared root canals, the samples were kept at 37ºC in distilled water for 7 days and subsequently submitted to the traction test in a universal testing machine (Instron 4444). The results showed no statistical difference between the groups. Diameter variation (0.9 mm, 1.3 mm and 1.7 mm) in abraded cylindrical posts cemented with zinc phosphate did not affect resistance to removal. |
id |
SBPQO-1_a4ca94e0c1ae41342cc793090ebabbe0 |
---|---|
oai_identifier_str |
oai:scielo:S1806-83242004000300011 |
network_acronym_str |
SBPQO-1 |
network_name_str |
Brazilian Oral Research |
repository_id_str |
|
spelling |
Effect of the diameter on Cu-Al post retentionTensile strengthPost and core techniqueThis study compared the resistance to removal by traction of abraded cylindrical metal cast posts of Cu-Al (Goldent-LA). The posts had constant length (9 mm) and three different diameters (0.9, 1.3 and 1.7 mm), and were cemented with zinc phosphate cement. The crowns of 36 sound maxillary canines were sectioned, the roots were immersed in resin blocks and the root canals were endodontically treated. The teeth were divided into three groups to be prepared and standardized with the use of a parallelometer with the following burs: Group 1 - Largo n. 2; Group 2 - Largo n. 4; Group 3 - Largo n. 6. The posts were molded with chemically activated resin and after casting they were abraded and their dimensions were confirmed with a digital caliper. After cementation of the posts in the prepared root canals, the samples were kept at 37ºC in distilled water for 7 days and subsequently submitted to the traction test in a universal testing machine (Instron 4444). The results showed no statistical difference between the groups. Diameter variation (0.9 mm, 1.3 mm and 1.7 mm) in abraded cylindrical posts cemented with zinc phosphate did not affect resistance to removal.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2004-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300011Brazilian Oral Research v.18 n.3 2004reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242004000300011info:eu-repo/semantics/openAccessSouza Filho,Celso Bernardo dePaulino,Silvana MariaAlfredo,EdsonSousa Neto,Manoel Damião deVansan,Luiz Pascoaleng2004-09-29T00:00:00Zoai:scielo:S1806-83242004000300011Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2004-09-29T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false |
dc.title.none.fl_str_mv |
Effect of the diameter on Cu-Al post retention |
title |
Effect of the diameter on Cu-Al post retention |
spellingShingle |
Effect of the diameter on Cu-Al post retention Souza Filho,Celso Bernardo de Tensile strength Post and core technique |
title_short |
Effect of the diameter on Cu-Al post retention |
title_full |
Effect of the diameter on Cu-Al post retention |
title_fullStr |
Effect of the diameter on Cu-Al post retention |
title_full_unstemmed |
Effect of the diameter on Cu-Al post retention |
title_sort |
Effect of the diameter on Cu-Al post retention |
author |
Souza Filho,Celso Bernardo de |
author_facet |
Souza Filho,Celso Bernardo de Paulino,Silvana Maria Alfredo,Edson Sousa Neto,Manoel Damião de Vansan,Luiz Pascoal |
author_role |
author |
author2 |
Paulino,Silvana Maria Alfredo,Edson Sousa Neto,Manoel Damião de Vansan,Luiz Pascoal |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Souza Filho,Celso Bernardo de Paulino,Silvana Maria Alfredo,Edson Sousa Neto,Manoel Damião de Vansan,Luiz Pascoal |
dc.subject.por.fl_str_mv |
Tensile strength Post and core technique |
topic |
Tensile strength Post and core technique |
description |
This study compared the resistance to removal by traction of abraded cylindrical metal cast posts of Cu-Al (Goldent-LA). The posts had constant length (9 mm) and three different diameters (0.9, 1.3 and 1.7 mm), and were cemented with zinc phosphate cement. The crowns of 36 sound maxillary canines were sectioned, the roots were immersed in resin blocks and the root canals were endodontically treated. The teeth were divided into three groups to be prepared and standardized with the use of a parallelometer with the following burs: Group 1 - Largo n. 2; Group 2 - Largo n. 4; Group 3 - Largo n. 6. The posts were molded with chemically activated resin and after casting they were abraded and their dimensions were confirmed with a digital caliper. After cementation of the posts in the prepared root canals, the samples were kept at 37ºC in distilled water for 7 days and subsequently submitted to the traction test in a universal testing machine (Instron 4444). The results showed no statistical difference between the groups. Diameter variation (0.9 mm, 1.3 mm and 1.7 mm) in abraded cylindrical posts cemented with zinc phosphate did not affect resistance to removal. |
publishDate |
2004 |
dc.date.none.fl_str_mv |
2004-09-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300011 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300011 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S1806-83242004000300011 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
publisher.none.fl_str_mv |
Sociedade Brasileira de Pesquisa Odontológica - SBPqO |
dc.source.none.fl_str_mv |
Brazilian Oral Research v.18 n.3 2004 reponame:Brazilian Oral Research instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO) instacron:SBPQO |
instname_str |
Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
instacron_str |
SBPQO |
institution |
SBPQO |
reponame_str |
Brazilian Oral Research |
collection |
Brazilian Oral Research |
repository.name.fl_str_mv |
Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO) |
repository.mail.fl_str_mv |
pob@edu.usp.br||bor@sbpqo.org.br |
_version_ |
1750318320318414848 |