Effect of the diameter on Cu-Al post retention

Detalhes bibliográficos
Autor(a) principal: Souza Filho,Celso Bernardo de
Data de Publicação: 2004
Outros Autores: Paulino,Silvana Maria, Alfredo,Edson, Sousa Neto,Manoel Damião de, Vansan,Luiz Pascoal
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300011
Resumo: This study compared the resistance to removal by traction of abraded cylindrical metal cast posts of Cu-Al (Goldent-LA). The posts had constant length (9 mm) and three different diameters (0.9, 1.3 and 1.7 mm), and were cemented with zinc phosphate cement. The crowns of 36 sound maxillary canines were sectioned, the roots were immersed in resin blocks and the root canals were endodontically treated. The teeth were divided into three groups to be prepared and standardized with the use of a parallelometer with the following burs: Group 1 - Largo n. 2; Group 2 - Largo n. 4; Group 3 - Largo n. 6. The posts were molded with chemically activated resin and after casting they were abraded and their dimensions were confirmed with a digital caliper. After cementation of the posts in the prepared root canals, the samples were kept at 37ºC in distilled water for 7 days and subsequently submitted to the traction test in a universal testing machine (Instron 4444). The results showed no statistical difference between the groups. Diameter variation (0.9 mm, 1.3 mm and 1.7 mm) in abraded cylindrical posts cemented with zinc phosphate did not affect resistance to removal.
id SBPQO-1_a4ca94e0c1ae41342cc793090ebabbe0
oai_identifier_str oai:scielo:S1806-83242004000300011
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Effect of the diameter on Cu-Al post retentionTensile strengthPost and core techniqueThis study compared the resistance to removal by traction of abraded cylindrical metal cast posts of Cu-Al (Goldent-LA). The posts had constant length (9 mm) and three different diameters (0.9, 1.3 and 1.7 mm), and were cemented with zinc phosphate cement. The crowns of 36 sound maxillary canines were sectioned, the roots were immersed in resin blocks and the root canals were endodontically treated. The teeth were divided into three groups to be prepared and standardized with the use of a parallelometer with the following burs: Group 1 - Largo n. 2; Group 2 - Largo n. 4; Group 3 - Largo n. 6. The posts were molded with chemically activated resin and after casting they were abraded and their dimensions were confirmed with a digital caliper. After cementation of the posts in the prepared root canals, the samples were kept at 37ºC in distilled water for 7 days and subsequently submitted to the traction test in a universal testing machine (Instron 4444). The results showed no statistical difference between the groups. Diameter variation (0.9 mm, 1.3 mm and 1.7 mm) in abraded cylindrical posts cemented with zinc phosphate did not affect resistance to removal.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2004-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300011Brazilian Oral Research v.18 n.3 2004reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242004000300011info:eu-repo/semantics/openAccessSouza Filho,Celso Bernardo dePaulino,Silvana MariaAlfredo,EdsonSousa Neto,Manoel Damião deVansan,Luiz Pascoaleng2004-09-29T00:00:00Zoai:scielo:S1806-83242004000300011Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2004-09-29T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Effect of the diameter on Cu-Al post retention
title Effect of the diameter on Cu-Al post retention
spellingShingle Effect of the diameter on Cu-Al post retention
Souza Filho,Celso Bernardo de
Tensile strength
Post and core technique
title_short Effect of the diameter on Cu-Al post retention
title_full Effect of the diameter on Cu-Al post retention
title_fullStr Effect of the diameter on Cu-Al post retention
title_full_unstemmed Effect of the diameter on Cu-Al post retention
title_sort Effect of the diameter on Cu-Al post retention
author Souza Filho,Celso Bernardo de
author_facet Souza Filho,Celso Bernardo de
Paulino,Silvana Maria
Alfredo,Edson
Sousa Neto,Manoel Damião de
Vansan,Luiz Pascoal
author_role author
author2 Paulino,Silvana Maria
Alfredo,Edson
Sousa Neto,Manoel Damião de
Vansan,Luiz Pascoal
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Souza Filho,Celso Bernardo de
Paulino,Silvana Maria
Alfredo,Edson
Sousa Neto,Manoel Damião de
Vansan,Luiz Pascoal
dc.subject.por.fl_str_mv Tensile strength
Post and core technique
topic Tensile strength
Post and core technique
description This study compared the resistance to removal by traction of abraded cylindrical metal cast posts of Cu-Al (Goldent-LA). The posts had constant length (9 mm) and three different diameters (0.9, 1.3 and 1.7 mm), and were cemented with zinc phosphate cement. The crowns of 36 sound maxillary canines were sectioned, the roots were immersed in resin blocks and the root canals were endodontically treated. The teeth were divided into three groups to be prepared and standardized with the use of a parallelometer with the following burs: Group 1 - Largo n. 2; Group 2 - Largo n. 4; Group 3 - Largo n. 6. The posts were molded with chemically activated resin and after casting they were abraded and their dimensions were confirmed with a digital caliper. After cementation of the posts in the prepared root canals, the samples were kept at 37ºC in distilled water for 7 days and subsequently submitted to the traction test in a universal testing machine (Instron 4444). The results showed no statistical difference between the groups. Diameter variation (0.9 mm, 1.3 mm and 1.7 mm) in abraded cylindrical posts cemented with zinc phosphate did not affect resistance to removal.
publishDate 2004
dc.date.none.fl_str_mv 2004-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300011
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242004000300011
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242004000300011
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.18 n.3 2004
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318320318414848