Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology

Detalhes bibliográficos
Autor(a) principal: Borba,Marcia
Data de Publicação: 2013
Outros Autores: Miranda Jr.,Walter Gomes, Cesar,Paulo Francisco, Griggs,Jason Allan, Bona,Alvaro Della
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Brazilian Oral Research
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500396
Resumo: The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm2 connector cross-sections using a LAVATM CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross-sectional images. Five measuring points were selected, as follows: MG - marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α= 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 µm). OA had the highest median gap dimension (125 µm), followed by the AOT point (105 µm). CA and AW gap width values were statistically similar, 66 and 65 µm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations.
id SBPQO-1_fdb46e4190c14f059e82fffcc1f3566e
oai_identifier_str oai:scielo:S1806-83242013000500396
network_acronym_str SBPQO-1
network_name_str Brazilian Oral Research
repository_id_str
spelling Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technologyComputer-Aided DesignDenture, Partial, FixedCeramicsThe objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm2 connector cross-sections using a LAVATM CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross-sectional images. Five measuring points were selected, as follows: MG - marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α= 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 µm). OA had the highest median gap dimension (125 µm), followed by the AOT point (105 µm). CA and AW gap width values were statistically similar, 66 and 65 µm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations.Sociedade Brasileira de Pesquisa Odontológica - SBPqO2013-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500396Brazilian Oral Research v.27 n.5 2013reponame:Brazilian Oral Researchinstname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)instacron:SBPQO10.1590/S1806-83242013000500003info:eu-repo/semantics/openAccessBorba,MarciaMiranda Jr.,Walter GomesCesar,Paulo FranciscoGriggs,Jason AllanBona,Alvaro Dellaeng2013-10-08T00:00:00Zoai:scielo:S1806-83242013000500396Revistahttps://www.scielo.br/j/bor/https://old.scielo.br/oai/scielo-oai.phppob@edu.usp.br||bor@sbpqo.org.br1807-31071806-8324opendoar:2013-10-08T00:00Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)false
dc.title.none.fl_str_mv Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology
title Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology
spellingShingle Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology
Borba,Marcia
Computer-Aided Design
Denture, Partial, Fixed
Ceramics
title_short Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology
title_full Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology
title_fullStr Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology
title_full_unstemmed Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology
title_sort Evaluation of the adaptation of zirconia-based fixed partial dentures using micro-CT technology
author Borba,Marcia
author_facet Borba,Marcia
Miranda Jr.,Walter Gomes
Cesar,Paulo Francisco
Griggs,Jason Allan
Bona,Alvaro Della
author_role author
author2 Miranda Jr.,Walter Gomes
Cesar,Paulo Francisco
Griggs,Jason Allan
Bona,Alvaro Della
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Borba,Marcia
Miranda Jr.,Walter Gomes
Cesar,Paulo Francisco
Griggs,Jason Allan
Bona,Alvaro Della
dc.subject.por.fl_str_mv Computer-Aided Design
Denture, Partial, Fixed
Ceramics
topic Computer-Aided Design
Denture, Partial, Fixed
Ceramics
description The objective of the study was to measure the marginal and internal fit of zirconia-based all-ceramic three-unit fixed partial dentures (FPDs) (Y-TZP - LAVA, 3M-ESPE), using a novel methodology based on micro-computed tomography (micro-CT) technology. Stainless steel models of prepared abutments were fabricated to design FPDs. Ten frameworks were produced with 9 mm2 connector cross-sections using a LAVATM CAD-CAM system. All FPDs were veneered with a compatible porcelain. Each FPD was seated on the original model and scanned using micro-CT. Files were processed using NRecon and CTAn software. Adobe Photoshop and Image J software were used to analyze the cross-sectional images. Five measuring points were selected, as follows: MG - marginal gap; CA - chamfer area; AW - axial wall; AOT - axio-occlusal transition area; OA - occlusal area. Results were statistically analyzed by Kruskall-Wallis and Tukey's post hoc test (α= 0.05). There were significant differences for the gap width between the measurement points evaluated. MG showed the smallest median gap width (42 µm). OA had the highest median gap dimension (125 µm), followed by the AOT point (105 µm). CA and AW gap width values were statistically similar, 66 and 65 µm respectively. Thus, it was possible to conclude that different levels of adaptation were observed within the FPD, at the different measuring points. In addition, the micro-CT technology seems to be a reliable tool to evaluate the fit of dental restorations.
publishDate 2013
dc.date.none.fl_str_mv 2013-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500396
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S1806-83242013000500396
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S1806-83242013000500003
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
publisher.none.fl_str_mv Sociedade Brasileira de Pesquisa Odontológica - SBPqO
dc.source.none.fl_str_mv Brazilian Oral Research v.27 n.5 2013
reponame:Brazilian Oral Research
instname:Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron:SBPQO
instname_str Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
instacron_str SBPQO
institution SBPQO
reponame_str Brazilian Oral Research
collection Brazilian Oral Research
repository.name.fl_str_mv Brazilian Oral Research - Sociedade Brasileira de Pesquisa Odontológica (SBPqO)
repository.mail.fl_str_mv pob@edu.usp.br||bor@sbpqo.org.br
_version_ 1750318323412762624