Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode

Detalhes bibliográficos
Autor(a) principal: Santos,Anderson M.
Data de Publicação: 2015
Outros Autores: Vicentini,Fernando C., Deroco,Patrícia B., Rocha-Filho,Romeu C., Fatibello-Filho,Orlando
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015001002159
Resumo: Simple, fast, and inexpensive electroanalytical procedures were developed for the determination of codeine (COD) solely and paracetamol (PCT) and COD simultaneously in pharmaceutical formulations and human body fluids. The methods involve the combination of square-wave voltammetry (SWV) with a cathodically pretreated boron-doped diamond electrode and a 0.2 mol L–1 acetate buffer (pH 4.0) solution as the supporting electrolyte. Significantly low limits of detection were obtained for COD solely or PCT and COD simultaneously: 1.19 or 18 and 14 nmol L–1, respectively. The proposed SWV method was successfully applied in the simultaneous determination of PCT and COD in four samples of pharmaceutical tablets, with results similar (at 98% confidence level) to those obtained using a reference high-performance liquid chromatography (HPLC) method. Additionally, adequate results were obtained when concentrations of PCT and COD were determined in human urine or serum samples by addition-recovery. Clearly, the proposed method is an excellent option for the determination of COD solely or PCT and COD simultaneously.
id SBQ-2_31ad9ff77b448e893d0034c836aec910
oai_identifier_str oai:scielo:S0103-50532015001002159
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond ElectrodeacetaminophenBDD electrodedetermination of drugselectrochemical pretreatmentsquare-wave voltammetrySimple, fast, and inexpensive electroanalytical procedures were developed for the determination of codeine (COD) solely and paracetamol (PCT) and COD simultaneously in pharmaceutical formulations and human body fluids. The methods involve the combination of square-wave voltammetry (SWV) with a cathodically pretreated boron-doped diamond electrode and a 0.2 mol L–1 acetate buffer (pH 4.0) solution as the supporting electrolyte. Significantly low limits of detection were obtained for COD solely or PCT and COD simultaneously: 1.19 or 18 and 14 nmol L–1, respectively. The proposed SWV method was successfully applied in the simultaneous determination of PCT and COD in four samples of pharmaceutical tablets, with results similar (at 98% confidence level) to those obtained using a reference high-performance liquid chromatography (HPLC) method. Additionally, adequate results were obtained when concentrations of PCT and COD were determined in human urine or serum samples by addition-recovery. Clearly, the proposed method is an excellent option for the determination of COD solely or PCT and COD simultaneously.Sociedade Brasileira de Química2015-10-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015001002159Journal of the Brazilian Chemical Society v.26 n.10 2015reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0103-5053.20150203info:eu-repo/semantics/openAccessSantos,Anderson M.Vicentini,Fernando C.Deroco,Patrícia B.Rocha-Filho,Romeu C.Fatibello-Filho,Orlandoeng2015-10-22T00:00:00Zoai:scielo:S0103-50532015001002159Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2015-10-22T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode
title Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode
spellingShingle Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode
Santos,Anderson M.
acetaminophen
BDD electrode
determination of drugs
electrochemical pretreatment
square-wave voltammetry
title_short Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode
title_full Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode
title_fullStr Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode
title_full_unstemmed Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode
title_sort Square-Wave Voltammetric Determination of Paracetamol and Codeine in Pharmaceutical and Human Body Fluid Samples Using a Cathodically Pretreated Boron-Doped Diamond Electrode
author Santos,Anderson M.
author_facet Santos,Anderson M.
Vicentini,Fernando C.
Deroco,Patrícia B.
Rocha-Filho,Romeu C.
Fatibello-Filho,Orlando
author_role author
author2 Vicentini,Fernando C.
Deroco,Patrícia B.
Rocha-Filho,Romeu C.
Fatibello-Filho,Orlando
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Santos,Anderson M.
Vicentini,Fernando C.
Deroco,Patrícia B.
Rocha-Filho,Romeu C.
Fatibello-Filho,Orlando
dc.subject.por.fl_str_mv acetaminophen
BDD electrode
determination of drugs
electrochemical pretreatment
square-wave voltammetry
topic acetaminophen
BDD electrode
determination of drugs
electrochemical pretreatment
square-wave voltammetry
description Simple, fast, and inexpensive electroanalytical procedures were developed for the determination of codeine (COD) solely and paracetamol (PCT) and COD simultaneously in pharmaceutical formulations and human body fluids. The methods involve the combination of square-wave voltammetry (SWV) with a cathodically pretreated boron-doped diamond electrode and a 0.2 mol L–1 acetate buffer (pH 4.0) solution as the supporting electrolyte. Significantly low limits of detection were obtained for COD solely or PCT and COD simultaneously: 1.19 or 18 and 14 nmol L–1, respectively. The proposed SWV method was successfully applied in the simultaneous determination of PCT and COD in four samples of pharmaceutical tablets, with results similar (at 98% confidence level) to those obtained using a reference high-performance liquid chromatography (HPLC) method. Additionally, adequate results were obtained when concentrations of PCT and COD were determined in human urine or serum samples by addition-recovery. Clearly, the proposed method is an excellent option for the determination of COD solely or PCT and COD simultaneously.
publishDate 2015
dc.date.none.fl_str_mv 2015-10-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015001002159
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532015001002159
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0103-5053.20150203
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.26 n.10 2015
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318177813790720