Quantification of pharmaceuticals and personal care product residues in surface and drinking water samples by SPE and LC-ESI-MS/MS

Detalhes bibliográficos
Autor(a) principal: Silveira,Maria Angelis K.
Data de Publicação: 2013
Outros Autores: Caldas,Sergiane S., Guilherme,Juliana R., Costa,Fabiane P., Guimarães,Bruno de S., Cerqueira,Maristela B. R., Soares,Bruno M., Primel,Ednei G.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Journal of the Brazilian Chemical Society (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532013000900001
Resumo: Currently, industrialized nations have faced a new problem, the contamination of water by emerging contaminants, such as pharmaceuticals and personal care products (PPCPs). A method based on solid-phase extraction (SPE) and liquid chromatography with electrospray ionization source tandem mass spectrometry was developed and validated for the determination of nimesulide, amitriptyline, enalapril, glibenclamide, haloperidol and methylparaben in water samples. In the study of SPE, a 2v5-1 fractional factorial design was used as a tool for the selection of the most significant variables in the extraction efficiency of the analytes under study. The limits of detection and quantification ranged from 0.01 to 0.2 µg L-1 and 0.05 to 1.0 µg L-1, respectively. Good linearity was obtained by a correlation coefficient (r) > 0.99 for all compounds. Recoveries ranged from 65 and 120% with relative standard deviation (RSD) lower than 20%. The method was applied to the determination of PPCPs in samples of surface and drinking water for three months. PPCPs were detected at µg L-1 levels.
id SBQ-2_aea67c1ef32be7ced0b3e83e51af1889
oai_identifier_str oai:scielo:S0103-50532013000900001
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Quantification of pharmaceuticals and personal care product residues in surface and drinking water samples by SPE and LC-ESI-MS/MSSPEpharmaceuticalspersonal care productsLC-ESI-MS/MSmatrix effectCurrently, industrialized nations have faced a new problem, the contamination of water by emerging contaminants, such as pharmaceuticals and personal care products (PPCPs). A method based on solid-phase extraction (SPE) and liquid chromatography with electrospray ionization source tandem mass spectrometry was developed and validated for the determination of nimesulide, amitriptyline, enalapril, glibenclamide, haloperidol and methylparaben in water samples. In the study of SPE, a 2v5-1 fractional factorial design was used as a tool for the selection of the most significant variables in the extraction efficiency of the analytes under study. The limits of detection and quantification ranged from 0.01 to 0.2 µg L-1 and 0.05 to 1.0 µg L-1, respectively. Good linearity was obtained by a correlation coefficient (r) > 0.99 for all compounds. Recoveries ranged from 65 and 120% with relative standard deviation (RSD) lower than 20%. The method was applied to the determination of PPCPs in samples of surface and drinking water for three months. PPCPs were detected at µg L-1 levels.Sociedade Brasileira de Química2013-09-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532013000900001Journal of the Brazilian Chemical Society v.24 n.9 2013reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.5935/0103-5053.20130176info:eu-repo/semantics/openAccessSilveira,Maria Angelis K.Caldas,Sergiane S.Guilherme,Juliana R.Costa,Fabiane P.Guimarães,Bruno de S.Cerqueira,Maristela B. R.Soares,Bruno M.Primel,Ednei G.eng2013-09-24T00:00:00Zoai:scielo:S0103-50532013000900001Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2013-09-24T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Quantification of pharmaceuticals and personal care product residues in surface and drinking water samples by SPE and LC-ESI-MS/MS
title Quantification of pharmaceuticals and personal care product residues in surface and drinking water samples by SPE and LC-ESI-MS/MS
spellingShingle Quantification of pharmaceuticals and personal care product residues in surface and drinking water samples by SPE and LC-ESI-MS/MS
Silveira,Maria Angelis K.
SPE
pharmaceuticals
personal care products
LC-ESI-MS/MS
matrix effect
title_short Quantification of pharmaceuticals and personal care product residues in surface and drinking water samples by SPE and LC-ESI-MS/MS
title_full Quantification of pharmaceuticals and personal care product residues in surface and drinking water samples by SPE and LC-ESI-MS/MS
title_fullStr Quantification of pharmaceuticals and personal care product residues in surface and drinking water samples by SPE and LC-ESI-MS/MS
title_full_unstemmed Quantification of pharmaceuticals and personal care product residues in surface and drinking water samples by SPE and LC-ESI-MS/MS
title_sort Quantification of pharmaceuticals and personal care product residues in surface and drinking water samples by SPE and LC-ESI-MS/MS
author Silveira,Maria Angelis K.
author_facet Silveira,Maria Angelis K.
Caldas,Sergiane S.
Guilherme,Juliana R.
Costa,Fabiane P.
Guimarães,Bruno de S.
Cerqueira,Maristela B. R.
Soares,Bruno M.
Primel,Ednei G.
author_role author
author2 Caldas,Sergiane S.
Guilherme,Juliana R.
Costa,Fabiane P.
Guimarães,Bruno de S.
Cerqueira,Maristela B. R.
Soares,Bruno M.
Primel,Ednei G.
author2_role author
author
author
author
author
author
author
dc.contributor.author.fl_str_mv Silveira,Maria Angelis K.
Caldas,Sergiane S.
Guilherme,Juliana R.
Costa,Fabiane P.
Guimarães,Bruno de S.
Cerqueira,Maristela B. R.
Soares,Bruno M.
Primel,Ednei G.
dc.subject.por.fl_str_mv SPE
pharmaceuticals
personal care products
LC-ESI-MS/MS
matrix effect
topic SPE
pharmaceuticals
personal care products
LC-ESI-MS/MS
matrix effect
description Currently, industrialized nations have faced a new problem, the contamination of water by emerging contaminants, such as pharmaceuticals and personal care products (PPCPs). A method based on solid-phase extraction (SPE) and liquid chromatography with electrospray ionization source tandem mass spectrometry was developed and validated for the determination of nimesulide, amitriptyline, enalapril, glibenclamide, haloperidol and methylparaben in water samples. In the study of SPE, a 2v5-1 fractional factorial design was used as a tool for the selection of the most significant variables in the extraction efficiency of the analytes under study. The limits of detection and quantification ranged from 0.01 to 0.2 µg L-1 and 0.05 to 1.0 µg L-1, respectively. Good linearity was obtained by a correlation coefficient (r) > 0.99 for all compounds. Recoveries ranged from 65 and 120% with relative standard deviation (RSD) lower than 20%. The method was applied to the determination of PPCPs in samples of surface and drinking water for three months. PPCPs were detected at µg L-1 levels.
publishDate 2013
dc.date.none.fl_str_mv 2013-09-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532013000900001
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532013000900001
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.5935/0103-5053.20130176
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.24 n.9 2013
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318175256313856