Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode

Bibliographic Details
Main Author: Calixto,Carolina M. F.
Publication Date: 2012
Other Authors: Cervini,Priscila, Cavalheiro,Éder T. G.
Format: Article
Language: eng
Source: Journal of the Brazilian Chemical Society (Online)
Download full: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000500020
Summary: A bare graphite-polyurethane composite was evaluated in the tetracycline (TC) determination in natural water samples. Using differential pulse voltammetry (DPV), a linear response was observed in the range of 4.00-40.0 µmol L-1 with limit of detection of 2.80 µmol L-1, without the need of surface renewing between successive runs. During the tetracycline determination in water samples, recoveries between 92.6 and 100% were found. The results for TC determination in water samples after a pre-concentration stage agreed with spiked value at a 95% confidence level according to student t-test.
id SBQ-2_f2547163753dbeba15e757f97a365b8e
oai_identifier_str oai:scielo:S0103-50532012000500020
network_acronym_str SBQ-2
network_name_str Journal of the Brazilian Chemical Society (Online)
repository_id_str
spelling Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrodetetracyclinegraphite-polyurethane composite electrodenatural waterA bare graphite-polyurethane composite was evaluated in the tetracycline (TC) determination in natural water samples. Using differential pulse voltammetry (DPV), a linear response was observed in the range of 4.00-40.0 µmol L-1 with limit of detection of 2.80 µmol L-1, without the need of surface renewing between successive runs. During the tetracycline determination in water samples, recoveries between 92.6 and 100% were found. The results for TC determination in water samples after a pre-concentration stage agreed with spiked value at a 95% confidence level according to student t-test.Sociedade Brasileira de Química2012-05-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000500020Journal of the Brazilian Chemical Society v.23 n.5 2012reponame:Journal of the Brazilian Chemical Society (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0103-50532012000500020info:eu-repo/semantics/openAccessCalixto,Carolina M. F.Cervini,PriscilaCavalheiro,Éder T. G.eng2012-06-01T00:00:00Zoai:scielo:S0103-50532012000500020Revistahttp://jbcs.sbq.org.brONGhttps://old.scielo.br/oai/scielo-oai.php||office@jbcs.sbq.org.br1678-47900103-5053opendoar:2012-06-01T00:00Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)false
dc.title.none.fl_str_mv Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode
title Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode
spellingShingle Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode
Calixto,Carolina M. F.
tetracycline
graphite-polyurethane composite electrode
natural water
title_short Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode
title_full Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode
title_fullStr Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode
title_full_unstemmed Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode
title_sort Determination of tetracycline in environmental water samples at a graphite-polyurethane composite electrode
author Calixto,Carolina M. F.
author_facet Calixto,Carolina M. F.
Cervini,Priscila
Cavalheiro,Éder T. G.
author_role author
author2 Cervini,Priscila
Cavalheiro,Éder T. G.
author2_role author
author
dc.contributor.author.fl_str_mv Calixto,Carolina M. F.
Cervini,Priscila
Cavalheiro,Éder T. G.
dc.subject.por.fl_str_mv tetracycline
graphite-polyurethane composite electrode
natural water
topic tetracycline
graphite-polyurethane composite electrode
natural water
description A bare graphite-polyurethane composite was evaluated in the tetracycline (TC) determination in natural water samples. Using differential pulse voltammetry (DPV), a linear response was observed in the range of 4.00-40.0 µmol L-1 with limit of detection of 2.80 µmol L-1, without the need of surface renewing between successive runs. During the tetracycline determination in water samples, recoveries between 92.6 and 100% were found. The results for TC determination in water samples after a pre-concentration stage agreed with spiked value at a 95% confidence level according to student t-test.
publishDate 2012
dc.date.none.fl_str_mv 2012-05-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000500020
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0103-50532012000500020
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/S0103-50532012000500020
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Sociedade Brasileira de Química
publisher.none.fl_str_mv Sociedade Brasileira de Química
dc.source.none.fl_str_mv Journal of the Brazilian Chemical Society v.23 n.5 2012
reponame:Journal of the Brazilian Chemical Society (Online)
instname:Sociedade Brasileira de Química (SBQ)
instacron:SBQ
instname_str Sociedade Brasileira de Química (SBQ)
instacron_str SBQ
institution SBQ
reponame_str Journal of the Brazilian Chemical Society (Online)
collection Journal of the Brazilian Chemical Society (Online)
repository.name.fl_str_mv Journal of the Brazilian Chemical Society (Online) - Sociedade Brasileira de Química (SBQ)
repository.mail.fl_str_mv ||office@jbcs.sbq.org.br
_version_ 1750318173481074688