Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometry
Autor(a) principal: | |
---|---|
Data de Publicação: | 2008 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Química Nova (Online) |
Texto Completo: | http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422008000700005 |
Resumo: | A method was developed for quantification of Cd and Pb in ethanol fuel by filter furnace atomic absorption spectrometry. Filter furnace was used to eliminate the need for chemical modification, to stabilize volatile analytes and to allow the application of short pyrolysis step. The determinations in samples were carried out against calibration solutions prepared in ethanol. Recovery tests were made in seven commercial ethanol fuel samples with values between 90 and 120%. Limits of detection were 0.1 µg L-1 for Cd and 0.3 µg L-1 for Pb. Certified water samples (APS 1071, APS 1033, NIST 1643d, NIST 1640) were also used to evaluate accuracy and recoveries from 86.8% to115% were obtained. |
id |
SBQ-3_f77ca871a5084cb75d1b364aa1e0bb3b |
---|---|
oai_identifier_str |
oai:scielo:S0100-40422008000700005 |
network_acronym_str |
SBQ-3 |
network_name_str |
Química Nova (Online) |
repository_id_str |
|
spelling |
Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometryfilter furnace atomic absorption spectrometryfuel ethanolcadmiumA method was developed for quantification of Cd and Pb in ethanol fuel by filter furnace atomic absorption spectrometry. Filter furnace was used to eliminate the need for chemical modification, to stabilize volatile analytes and to allow the application of short pyrolysis step. The determinations in samples were carried out against calibration solutions prepared in ethanol. Recovery tests were made in seven commercial ethanol fuel samples with values between 90 and 120%. Limits of detection were 0.1 µg L-1 for Cd and 0.3 µg L-1 for Pb. Certified water samples (APS 1071, APS 1033, NIST 1643d, NIST 1640) were also used to evaluate accuracy and recoveries from 86.8% to115% were obtained.Sociedade Brasileira de Química2008-01-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422008000700005Química Nova v.31 n.7 2008reponame:Química Nova (Online)instname:Sociedade Brasileira de Química (SBQ)instacron:SBQ10.1590/S0100-40422008000700005info:eu-repo/semantics/openAccessSaint'Pierre,Tatiana D.Maranhão,Tatiane de A.Frescura,Vera L.Curtius,Adilson J.Aucélio,Ricardo Q.eng2008-12-09T00:00:00Zoai:scielo:S0100-40422008000700005Revistahttps://www.scielo.br/j/qn/ONGhttps://old.scielo.br/oai/scielo-oai.phpquimicanova@sbq.org.br1678-70640100-4042opendoar:2008-12-09T00:00Química Nova (Online) - Sociedade Brasileira de Química (SBQ)false |
dc.title.none.fl_str_mv |
Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometry |
title |
Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometry |
spellingShingle |
Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometry Saint'Pierre,Tatiana D. filter furnace atomic absorption spectrometry fuel ethanol cadmium |
title_short |
Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometry |
title_full |
Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometry |
title_fullStr |
Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometry |
title_full_unstemmed |
Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometry |
title_sort |
Determination of Cd and Pb in fuel ethanol by filter furnace electrothermal atomic absorption spectrometry |
author |
Saint'Pierre,Tatiana D. |
author_facet |
Saint'Pierre,Tatiana D. Maranhão,Tatiane de A. Frescura,Vera L. Curtius,Adilson J. Aucélio,Ricardo Q. |
author_role |
author |
author2 |
Maranhão,Tatiane de A. Frescura,Vera L. Curtius,Adilson J. Aucélio,Ricardo Q. |
author2_role |
author author author author |
dc.contributor.author.fl_str_mv |
Saint'Pierre,Tatiana D. Maranhão,Tatiane de A. Frescura,Vera L. Curtius,Adilson J. Aucélio,Ricardo Q. |
dc.subject.por.fl_str_mv |
filter furnace atomic absorption spectrometry fuel ethanol cadmium |
topic |
filter furnace atomic absorption spectrometry fuel ethanol cadmium |
description |
A method was developed for quantification of Cd and Pb in ethanol fuel by filter furnace atomic absorption spectrometry. Filter furnace was used to eliminate the need for chemical modification, to stabilize volatile analytes and to allow the application of short pyrolysis step. The determinations in samples were carried out against calibration solutions prepared in ethanol. Recovery tests were made in seven commercial ethanol fuel samples with values between 90 and 120%. Limits of detection were 0.1 µg L-1 for Cd and 0.3 µg L-1 for Pb. Certified water samples (APS 1071, APS 1033, NIST 1643d, NIST 1640) were also used to evaluate accuracy and recoveries from 86.8% to115% were obtained. |
publishDate |
2008 |
dc.date.none.fl_str_mv |
2008-01-01 |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422008000700005 |
url |
http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0100-40422008000700005 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
10.1590/S0100-40422008000700005 |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
text/html |
dc.publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
publisher.none.fl_str_mv |
Sociedade Brasileira de Química |
dc.source.none.fl_str_mv |
Química Nova v.31 n.7 2008 reponame:Química Nova (Online) instname:Sociedade Brasileira de Química (SBQ) instacron:SBQ |
instname_str |
Sociedade Brasileira de Química (SBQ) |
instacron_str |
SBQ |
institution |
SBQ |
reponame_str |
Química Nova (Online) |
collection |
Química Nova (Online) |
repository.name.fl_str_mv |
Química Nova (Online) - Sociedade Brasileira de Química (SBQ) |
repository.mail.fl_str_mv |
quimicanova@sbq.org.br |
_version_ |
1750318108017426432 |