Bioaerossóis na indústria farmacêutica

Detalhes bibliográficos
Autor(a) principal: Ferreira, Guilherme Neves
Data de Publicação: 2009
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UERJ
Texto Completo: http://www.bdtd.uerj.br/handle/1/15713
Resumo: This study had as objective to test a barrier against microbiological contamination in contact plates that are used in sterile pharmaceutical products clean rooms monitoring. During 2007 the tests were performed and compared with data from, 2004, 2005 and 2006, when the mentioned barrier was not used. The test environments were two clean rooms from a pharmaceutical plant located at Rio de Janeiro. In the mentioned environments the use of special garments is necessary for avoiding that particles from operators bodies, bacteria and most remain in contact with the room environment, adding risk to the sterilized products. So, it was proposed the use of undershirt between the garment and the operator skin for reducing the contact plate s contamination during the regular rooms monitoring. This undershirt was used during 2007 and the results were compared with the samples of 2004, 2005 and 2006 when the undershirt was not used. The results demonstrated that it was obtained a reduction of about 50% in relation to contaminated plates. In relation to the total number of colonies the reduction was 75% in comparison with 2004 and 2005, and 50% in comparison with 2006
id UERJ_73e936495c5aace6e65ac197672cf397
oai_identifier_str oai:www.bdtd.uerj.br:1/15713
network_acronym_str UERJ
network_name_str Biblioteca Digital de Teses e Dissertações da UERJ
repository_id_str 2903
spelling Corrêa, Sérgio Machadohttp://lattes.cnpq.br/0036129846822289Rodrigues, Denise Celeste Godoy de Andradehttp://lattes.cnpq.br/5002270818489370Souza, Simone Lorena Quitério dehttp://lattes.cnpq.br/9854874424161953http://lattes.cnpq.br/6486876882539154Ferreira, Guilherme Neves2021-01-07T19:01:36Z2011-08-102009-04-27FERREIRA, Guilherme Neves. Bioaerossóis na indústria farmacêutica. 2009. 90 f. Dissertação (Mestrado em Química ambiental; Polímeros) - Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2009.http://www.bdtd.uerj.br/handle/1/15713This study had as objective to test a barrier against microbiological contamination in contact plates that are used in sterile pharmaceutical products clean rooms monitoring. During 2007 the tests were performed and compared with data from, 2004, 2005 and 2006, when the mentioned barrier was not used. The test environments were two clean rooms from a pharmaceutical plant located at Rio de Janeiro. In the mentioned environments the use of special garments is necessary for avoiding that particles from operators bodies, bacteria and most remain in contact with the room environment, adding risk to the sterilized products. So, it was proposed the use of undershirt between the garment and the operator skin for reducing the contact plate s contamination during the regular rooms monitoring. This undershirt was used during 2007 and the results were compared with the samples of 2004, 2005 and 2006 when the undershirt was not used. The results demonstrated that it was obtained a reduction of about 50% in relation to contaminated plates. In relation to the total number of colonies the reduction was 75% in comparison with 2004 and 2005, and 50% in comparison with 2006Este estudo teve como finalidade, testar uma barreira contra a contaminação microbiológica em placas de contato, utilizadas em monitoramento de salas limpas para fabricação de produtos farmacêuticos estéreis. Durante o ano de 2007, foram realizados testes de contato com a utilização da mencionada barreira, e os resultados foram comparados com dados dos anos de, 2004, 2005 e 2006, quando a barreira não foi utilizada. Os ambientes utilizados para os testes foram duas salas limpas de uma planta farmacêutica localizada no Rio de Janeiro. Nos mencionados ambientes é necessário o uso de uma vestimenta especial, de forma a evitar que partículas do corpo dos operadores, bactérias e fungos, migrem para a superfície externa do uniforme e coloquem em risco a esterilidade dos produtos. Sendo assim, foi proposta a colocação de uma camiseta diretamente sobre a pele do operador durante todo o ano de 2007 de forma a evitar ou reduzir a possibilidade de migração dessas partículas; e os resultados foram comparados com os anos de 2004, 2005 e 2006, quando a camiseta não foi usada. Os testes demonstraram que houve uma redução de cerca de 50% na ocorrência de placas contaminadas. Com relação ao número total de colônias formadas, a redução foi de 75% na comparação com os anos de 2004 e 2005 e de 50% com relação ao ano de 2006Submitted by Boris Flegr (boris@uerj.br) on 2021-01-07T19:01:36Z No. of bitstreams: 1 dissertacao guilherme neves ferreira.pdf: 847592 bytes, checksum: 82eb05d66cc06ebcbe64810b2125b7df (MD5)Made available in DSpace on 2021-01-07T19:01:36Z (GMT). No. of bitstreams: 1 dissertacao guilherme neves ferreira.pdf: 847592 bytes, checksum: 82eb05d66cc06ebcbe64810b2125b7df (MD5) Previous issue date: 2009-04-27application/pdfporUniversidade do Estado do Rio de JaneiroPrograma de Pós-Graduação em QuímicaUERJBRCentro de Tecnologia e Ciências::Instituto de QuímicaBarrierMicrobiological contaminationBarreiraContaminação microbiológicaCNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICABioaerossóis na indústria farmacêuticaBioareorols in the pharmaceutical industryinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisinfo:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UERJinstname:Universidade do Estado do Rio de Janeiro (UERJ)instacron:UERJORIGINALdissertacao guilherme neves ferreira.pdfapplication/pdf847592http://www.bdtd.uerj.br/bitstream/1/15713/1/dissertacao+guilherme+neves+ferreira.pdf82eb05d66cc06ebcbe64810b2125b7dfMD511/157132024-02-27 14:47:47.684oai:www.bdtd.uerj.br:1/15713Biblioteca Digital de Teses e Dissertaçõeshttp://www.bdtd.uerj.br/PUBhttps://www.bdtd.uerj.br:8443/oai/requestbdtd.suporte@uerj.bropendoar:29032024-02-27T17:47:47Biblioteca Digital de Teses e Dissertações da UERJ - Universidade do Estado do Rio de Janeiro (UERJ)false
dc.title.por.fl_str_mv Bioaerossóis na indústria farmacêutica
dc.title.alternative.eng.fl_str_mv Bioareorols in the pharmaceutical industry
title Bioaerossóis na indústria farmacêutica
spellingShingle Bioaerossóis na indústria farmacêutica
Ferreira, Guilherme Neves
Barrier
Microbiological contamination
Barreira
Contaminação microbiológica
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
title_short Bioaerossóis na indústria farmacêutica
title_full Bioaerossóis na indústria farmacêutica
title_fullStr Bioaerossóis na indústria farmacêutica
title_full_unstemmed Bioaerossóis na indústria farmacêutica
title_sort Bioaerossóis na indústria farmacêutica
author Ferreira, Guilherme Neves
author_facet Ferreira, Guilherme Neves
author_role author
dc.contributor.advisor1.fl_str_mv Corrêa, Sérgio Machado
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/0036129846822289
dc.contributor.referee1.fl_str_mv Rodrigues, Denise Celeste Godoy de Andrade
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/5002270818489370
dc.contributor.referee2.fl_str_mv Souza, Simone Lorena Quitério de
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/9854874424161953
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/6486876882539154
dc.contributor.author.fl_str_mv Ferreira, Guilherme Neves
contributor_str_mv Corrêa, Sérgio Machado
Rodrigues, Denise Celeste Godoy de Andrade
Souza, Simone Lorena Quitério de
dc.subject.eng.fl_str_mv Barrier
Microbiological contamination
topic Barrier
Microbiological contamination
Barreira
Contaminação microbiológica
CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
dc.subject.por.fl_str_mv Barreira
Contaminação microbiológica
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS EXATAS E DA TERRA::QUIMICA
description This study had as objective to test a barrier against microbiological contamination in contact plates that are used in sterile pharmaceutical products clean rooms monitoring. During 2007 the tests were performed and compared with data from, 2004, 2005 and 2006, when the mentioned barrier was not used. The test environments were two clean rooms from a pharmaceutical plant located at Rio de Janeiro. In the mentioned environments the use of special garments is necessary for avoiding that particles from operators bodies, bacteria and most remain in contact with the room environment, adding risk to the sterilized products. So, it was proposed the use of undershirt between the garment and the operator skin for reducing the contact plate s contamination during the regular rooms monitoring. This undershirt was used during 2007 and the results were compared with the samples of 2004, 2005 and 2006 when the undershirt was not used. The results demonstrated that it was obtained a reduction of about 50% in relation to contaminated plates. In relation to the total number of colonies the reduction was 75% in comparison with 2004 and 2005, and 50% in comparison with 2006
publishDate 2009
dc.date.issued.fl_str_mv 2009-04-27
dc.date.available.fl_str_mv 2011-08-10
dc.date.accessioned.fl_str_mv 2021-01-07T19:01:36Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv FERREIRA, Guilherme Neves. Bioaerossóis na indústria farmacêutica. 2009. 90 f. Dissertação (Mestrado em Química ambiental; Polímeros) - Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2009.
dc.identifier.uri.fl_str_mv http://www.bdtd.uerj.br/handle/1/15713
identifier_str_mv FERREIRA, Guilherme Neves. Bioaerossóis na indústria farmacêutica. 2009. 90 f. Dissertação (Mestrado em Química ambiental; Polímeros) - Universidade do Estado do Rio de Janeiro, Rio de Janeiro, 2009.
url http://www.bdtd.uerj.br/handle/1/15713
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade do Estado do Rio de Janeiro
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Química
dc.publisher.initials.fl_str_mv UERJ
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Centro de Tecnologia e Ciências::Instituto de Química
publisher.none.fl_str_mv Universidade do Estado do Rio de Janeiro
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UERJ
instname:Universidade do Estado do Rio de Janeiro (UERJ)
instacron:UERJ
instname_str Universidade do Estado do Rio de Janeiro (UERJ)
instacron_str UERJ
institution UERJ
reponame_str Biblioteca Digital de Teses e Dissertações da UERJ
collection Biblioteca Digital de Teses e Dissertações da UERJ
bitstream.url.fl_str_mv http://www.bdtd.uerj.br/bitstream/1/15713/1/dissertacao+guilherme+neves+ferreira.pdf
bitstream.checksum.fl_str_mv 82eb05d66cc06ebcbe64810b2125b7df
bitstream.checksumAlgorithm.fl_str_mv MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UERJ - Universidade do Estado do Rio de Janeiro (UERJ)
repository.mail.fl_str_mv bdtd.suporte@uerj.br
_version_ 1792352339109085184