An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy

Detalhes bibliográficos
Autor(a) principal: Ferreira, Sergio Luis Costa
Data de Publicação: 2000
Outros Autores: Lemos, Valfredo Azevedo, Moreira, Barbara C., Costa, Antonio Celso Spinola, Santelli, Ricardo Erthal
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UFBA
Texto Completo: http://www.repositorio.ufba.br/ri/handle/ri/7891
Resumo: Texto completo: acesso restrito. p. 259–264
id UFBA-2_fec4fe82b813281f80b493532f94e92d
oai_identifier_str oai:repositorio.ufba.br:ri/7891
network_acronym_str UFBA-2
network_name_str Repositório Institucional da UFBA
repository_id_str 1932
spelling Ferreira, Sergio Luis CostaLemos, Valfredo AzevedoMoreira, Barbara C.Costa, Antonio Celso SpinolaSantelli, Ricardo ErthalFerreira, Sergio Luis CostaLemos, Valfredo AzevedoMoreira, Barbara C.Costa, Antonio Celso SpinolaSantelli, Ricardo Erthal2013-01-16T12:47:02Z20000003-2670http://www.repositorio.ufba.br/ri/handle/ri/7891v. 403, n. 1-2Texto completo: acesso restrito. p. 259–264An on-line enrichment flow system has been developed in order to determine trace amounts of copper in seawater and biological samples. It is based on the chemical sorption of copper(II) ions onto a minicolumn packed with Amberlite XAD-2 resin loaded with calmagite reagent. After copper preconcentration, it was eluted by 1 mol l−1 hydrochloric acid solution and determined directly by flame atomic absorption spectrometry (FAAS). A preconcentration factor of 32 in 13.5 ml of sample (3 min preconcentration time) was achieved by using the time-based technique. The detection limit (3σ) was 0.15 μg l−1 and the precision (assessed as the relative standard deviation) reached values within the range of 2.7–6.0% in copper solutions varying from 0.0 to 20 μg l−1 concentration, respectively. Chemical and flow variables as well as concomitant were studied in the developed procedure. The method was tolerant to other ions usually present in the analyzed samples. The proposed procedure was successfully applied to determine copper in biological certified reference material. Achieved recoveries of copper in samples of seawater and biological material, measured by standard addition technique proved also that the proposed procedure has a good accuracy.Submitted by Suelen Reis (suelen_suzane@hotmail.com) on 2013-01-16T12:47:02Z No. of bitstreams: 1 Sérgio Ferreira.pdf: 63595 bytes, checksum: a9d419d1b1b6d23add258ad253cf9424 (MD5)Made available in DSpace on 2013-01-16T12:47:02Z (GMT). No. of bitstreams: 1 Sérgio Ferreira.pdf: 63595 bytes, checksum: a9d419d1b1b6d23add258ad253cf9424 (MD5) Previous issue date: 2000http://dx.doi.org/10.1016/S0003-2670(99)00632-7reponame:Repositório Institucional da UFBAinstname:Universidade Federal da Bahia (UFBA)instacron:UFBAFlame atomic absorption spectroscopyCopperPreconcentrationAn on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopyAnalytica Chimica Actainfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article10000-01-01enginfo:eu-repo/semantics/openAccessLICENSElicense.txtlicense.txttext/plain1762https://repositorio.ufba.br/bitstream/ri/7891/2/license.txt1b89a9a0548218172d7c829f87a0eab9MD52ORIGINALSérgio Ferreira.pdfSérgio Ferreira.pdfapplication/pdf63595https://repositorio.ufba.br/bitstream/ri/7891/1/S%c3%a9rgio%20Ferreira.pdfa9d419d1b1b6d23add258ad253cf9424MD51TEXTSérgio Ferreira.pdf.txtSérgio Ferreira.pdf.txtExtracted texttext/plain18331https://repositorio.ufba.br/bitstream/ri/7891/3/S%c3%a9rgio%20Ferreira.pdf.txt418f1104523f4ac43f73e957ecac8aa5MD53ri/78912022-07-05 14:03:23.312oai:repositorio.ufba.br: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Repositório InstitucionalPUBhttp://192.188.11.11:8080/oai/requestopendoar:19322022-07-05T17:03:23Repositório Institucional da UFBA - Universidade Federal da Bahia (UFBA)false
dc.title.pt_BR.fl_str_mv An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy
dc.title.alternative.pt_BR.fl_str_mv Analytica Chimica Acta
title An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy
spellingShingle An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy
Ferreira, Sergio Luis Costa
Flame atomic absorption spectroscopy
Copper
Preconcentration
title_short An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy
title_full An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy
title_fullStr An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy
title_full_unstemmed An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy
title_sort An on-line continuous flow system for copper enrichment and determination by flame atomic absorption spectroscopy
author Ferreira, Sergio Luis Costa
author_facet Ferreira, Sergio Luis Costa
Lemos, Valfredo Azevedo
Moreira, Barbara C.
Costa, Antonio Celso Spinola
Santelli, Ricardo Erthal
author_role author
author2 Lemos, Valfredo Azevedo
Moreira, Barbara C.
Costa, Antonio Celso Spinola
Santelli, Ricardo Erthal
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Ferreira, Sergio Luis Costa
Lemos, Valfredo Azevedo
Moreira, Barbara C.
Costa, Antonio Celso Spinola
Santelli, Ricardo Erthal
Ferreira, Sergio Luis Costa
Lemos, Valfredo Azevedo
Moreira, Barbara C.
Costa, Antonio Celso Spinola
Santelli, Ricardo Erthal
dc.subject.por.fl_str_mv Flame atomic absorption spectroscopy
Copper
Preconcentration
topic Flame atomic absorption spectroscopy
Copper
Preconcentration
description Texto completo: acesso restrito. p. 259–264
publishDate 2000
dc.date.issued.fl_str_mv 2000
dc.date.accessioned.fl_str_mv 2013-01-16T12:47:02Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.repositorio.ufba.br/ri/handle/ri/7891
dc.identifier.issn.none.fl_str_mv 0003-2670
dc.identifier.number.pt_BR.fl_str_mv v. 403, n. 1-2
identifier_str_mv 0003-2670
v. 403, n. 1-2
url http://www.repositorio.ufba.br/ri/handle/ri/7891
dc.language.iso.fl_str_mv eng
language eng
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.pt_BR.fl_str_mv http://dx.doi.org/10.1016/S0003-2670(99)00632-7
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFBA
instname:Universidade Federal da Bahia (UFBA)
instacron:UFBA
instname_str Universidade Federal da Bahia (UFBA)
instacron_str UFBA
institution UFBA
reponame_str Repositório Institucional da UFBA
collection Repositório Institucional da UFBA
bitstream.url.fl_str_mv https://repositorio.ufba.br/bitstream/ri/7891/2/license.txt
https://repositorio.ufba.br/bitstream/ri/7891/1/S%c3%a9rgio%20Ferreira.pdf
https://repositorio.ufba.br/bitstream/ri/7891/3/S%c3%a9rgio%20Ferreira.pdf.txt
bitstream.checksum.fl_str_mv 1b89a9a0548218172d7c829f87a0eab9
a9d419d1b1b6d23add258ad253cf9424
418f1104523f4ac43f73e957ecac8aa5
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFBA - Universidade Federal da Bahia (UFBA)
repository.mail.fl_str_mv
_version_ 1793970080689684480