Effectiveness of different excavation methods on removal of artificially demineralized dentin

Detalhes bibliográficos
Autor(a) principal: Patricia Maria Soares Lima The
Data de Publicação: 2012
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UFC
Texto Completo: http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=8882
Resumo: The aim of this study was to evaluate the effectiveness of three mechanical methods for removal of demineralized dentin. A total of thirty sound human third molars indicated for extraction. After extraction, the teeth were cleaned and stored properly. The occlusal enamel was removed with a diamond wheel to expose a flat dentin surface, and each tooth was sectioned longitudinally in the buccal-lingual direction. One half of each tooth was entirely covered with an acid-resistant varnish, except for an occlusal area of 16 mm2, and was submitted to pH-cycling model to produce demineralized dentin. The other half of each tooth was maintained with mineralized dentin. The pH-cycling procedure was taken in 8 days. Halves of teeth were reassembled with cyanoacrylate adhesive. Samples were randomly allocated into three groups according to the method of removal of demineralized dentin: G1 â steel bur, G2 â polymer bur; G3 â hand excavation. The procedure of demineralized dentin removal was performed by a single operator. Digital images were obtained and cavities depths were measured (Âm) using MacBiophotonics ImageJ software. Knoop microhardness measurements (kgf/mm2) were performed in all samples at 10 to 200 Âm depth from the bottom of cavities. Data for cavity depth and microhardness were analyzed using One-Way ANOVA and the post hoc tests (p<0.05). The steel bur provided a larger wear, resulting in a deeper depth after the removal of the demineralized dentin, followed by the hand excavator and the polymer bur had a lower depth. The hardness values obtained with the steel bur were higher, indicating that there was a higher standard of demineralized dentin removal, followed by the hand excavator. The use of polymer bur left dentin with low values of hardness, indicating that demineralized tissue still remained. The polymer bur looks to be more selective in the removal of the demineralized dentin when compared with the steel bur and the hand excavator.
id UFC_e0a7bd768d0edbb07e4a5c251b4c7856
oai_identifier_str oai:www.teses.ufc.br:5753
network_acronym_str UFC
network_name_str Biblioteca Digital de Teses e Dissertações da UFC
spelling info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesisEffectiveness of different excavation methods on removal of artificially demineralized dentinEfetividade de diferentes mÃtodos mecÃnicos na remoÃÃo de dentina desmineralizada2012-08-31Carlos Augusto de Oliveira Fernandes22216987387http://lattes.cnpq.br/6963754728640049 MÃnica Yamauti17060876839http://lattes.cnpq.br/9117580271037568Juliano Sartori MendonÃa14121591801http://buscatextual.cnpq.br/buscatextual/visualizacv.jsp?id=K4763253T5Renato Cilli15109605890http://lattes.cnpq.br/8229611840158890 88248828387http://lattes.cnpq.br/8479316963588595Patricia Maria Soares Lima TheUniversidade Federal do CearÃPrograma de PÃs-GraduaÃÃo em OdontologiaUFCBRDental caries dentin Demineralization HardnessODONTOLOGIAThe aim of this study was to evaluate the effectiveness of three mechanical methods for removal of demineralized dentin. A total of thirty sound human third molars indicated for extraction. After extraction, the teeth were cleaned and stored properly. The occlusal enamel was removed with a diamond wheel to expose a flat dentin surface, and each tooth was sectioned longitudinally in the buccal-lingual direction. One half of each tooth was entirely covered with an acid-resistant varnish, except for an occlusal area of 16 mm2, and was submitted to pH-cycling model to produce demineralized dentin. The other half of each tooth was maintained with mineralized dentin. The pH-cycling procedure was taken in 8 days. Halves of teeth were reassembled with cyanoacrylate adhesive. Samples were randomly allocated into three groups according to the method of removal of demineralized dentin: G1 â steel bur, G2 â polymer bur; G3 â hand excavation. The procedure of demineralized dentin removal was performed by a single operator. Digital images were obtained and cavities depths were measured (Âm) using MacBiophotonics ImageJ software. Knoop microhardness measurements (kgf/mm2) were performed in all samples at 10 to 200 Âm depth from the bottom of cavities. Data for cavity depth and microhardness were analyzed using One-Way ANOVA and the post hoc tests (p<0.05). The steel bur provided a larger wear, resulting in a deeper depth after the removal of the demineralized dentin, followed by the hand excavator and the polymer bur had a lower depth. The hardness values obtained with the steel bur were higher, indicating that there was a higher standard of demineralized dentin removal, followed by the hand excavator. The use of polymer bur left dentin with low values of hardness, indicating that demineralized tissue still remained. The polymer bur looks to be more selective in the removal of the demineralized dentin when compared with the steel bur and the hand excavator.O objetivo do estudo foi avaliar a efetividade de trÃs mÃtodos mecÃnicos na remoÃÃo de dentina desmineralizada. Utilizaram-se 30 terceiros molares humanos hÃgidos, indicados para extraÃÃo. ApÃs a extraÃÃo, os dentes foram devidamente limpos e armazenados. Removeu-se o esmalte oclusal com um disco de diamante para expor uma superfÃcie plana de dentina e seccionou-se cada dente longitudinalmente, no sentido vestÃbulo-lingual. Uma metade de cada dente foi totalmente coberta com um verniz Ãcido resistente, com exceÃÃo de uma Ãrea oclusal de 16 mm2, e submetida à ciclagem de pH para produzir dentina desmineralizada. A outra metade de cada dente foi mantida com a dentina mineralizada. A dentina desmineralizada foi criada por meio de procedimento de ciclagem de pH durante 8 dias. As metades dos dentes foram unidas novamente com adesivo de cianoacrilato. Alocaram-se aleatoriamente as amostras em trÃs grupos, segundo o mÃtodo de remoÃÃo da dentina desmineralizada: G1 â broca de aÃo esfÃrica; G2 â broca de polÃmero; G3 â cureta de dentina. Um Ãnico operador realizou o procedimento de remoÃÃo de dentina desmineralizada. ApÃs a remoÃÃo da dentina, as metades dos dentes foram separadas, incluÃdos em resina acrÃlica e polidas. As imagens digitais foram obtidas e as profundidades das cavidades foram medidas (Âm) com o uso do programa MacBiophotonics ImageJ. Realizaram-se medidas de dureza Knoop (kgf/mm2) em todas as amostras de 10 a 200 microns a partir do fundo das cavidades. Os dados de profundidade da cavidade e microdureza foram analisados utilizando One-Way ANOVA e os testes post hoc (p<0,05). A broca de aÃo proporcionou um maior desgaste, resultando em uma maior profundidade apÃs a remoÃÃo da dentina desmineralizada, seguida da cureta de dentina, e a broca de polÃmero teve uma menor profundidade. Os valores de dureza obtidos com o emprego da broca de aÃo foram maiores, o que indica que houve um padrÃo maior de remoÃÃo de dentina desmineralizada, seguidos dos valores da cureta de dentina, enquanto a broca de polÃmero apresentou nÃmeros menores de dureza, apontando ainda a presenÃa de tecido desmineralizado. A broca de polÃmero parece ser mais seletiva na remoÃÃo da dentina desmineralizada, quando comparada com a broca de aÃo e a cureta de dentina. CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superiorhttp://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=8882application/pdfinfo:eu-repo/semantics/openAccessporreponame:Biblioteca Digital de Teses e Dissertações da UFCinstname:Universidade Federal do Cearáinstacron:UFC2019-01-21T11:22:03Zmail@mail.com -
dc.title.en.fl_str_mv Effectiveness of different excavation methods on removal of artificially demineralized dentin
dc.title.alternative.pt.fl_str_mv Efetividade de diferentes mÃtodos mecÃnicos na remoÃÃo de dentina desmineralizada
title Effectiveness of different excavation methods on removal of artificially demineralized dentin
spellingShingle Effectiveness of different excavation methods on removal of artificially demineralized dentin
Patricia Maria Soares Lima The
Dental caries
dentin
Demineralization
Hardness
ODONTOLOGIA
title_short Effectiveness of different excavation methods on removal of artificially demineralized dentin
title_full Effectiveness of different excavation methods on removal of artificially demineralized dentin
title_fullStr Effectiveness of different excavation methods on removal of artificially demineralized dentin
title_full_unstemmed Effectiveness of different excavation methods on removal of artificially demineralized dentin
title_sort Effectiveness of different excavation methods on removal of artificially demineralized dentin
author Patricia Maria Soares Lima The
author_facet Patricia Maria Soares Lima The
author_role author
dc.contributor.advisor1.fl_str_mv Carlos Augusto de Oliveira Fernandes
dc.contributor.advisor1ID.fl_str_mv 22216987387
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/6963754728640049
dc.contributor.advisor-co1.fl_str_mv MÃnica Yamauti
dc.contributor.advisor-co1ID.fl_str_mv 17060876839
dc.contributor.advisor-co1Lattes.fl_str_mv http://lattes.cnpq.br/9117580271037568
dc.contributor.referee1.fl_str_mv Juliano Sartori MendonÃa
dc.contributor.referee1ID.fl_str_mv 14121591801
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.jsp?id=K4763253T5
dc.contributor.referee2.fl_str_mv Renato Cilli
dc.contributor.referee2ID.fl_str_mv 15109605890
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/8229611840158890
dc.contributor.authorID.fl_str_mv 88248828387
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/8479316963588595
dc.contributor.author.fl_str_mv Patricia Maria Soares Lima The
contributor_str_mv Carlos Augusto de Oliveira Fernandes
MÃnica Yamauti
Juliano Sartori MendonÃa
Renato Cilli
dc.subject.eng.fl_str_mv Dental caries
dentin
Demineralization
Hardness
topic Dental caries
dentin
Demineralization
Hardness
ODONTOLOGIA
dc.subject.cnpq.fl_str_mv ODONTOLOGIA
dc.description.sponsorship.fl_txt_mv CoordenaÃÃo de AperfeiÃoamento de Pessoal de NÃvel Superior
dc.description.abstract.por.fl_txt_mv The aim of this study was to evaluate the effectiveness of three mechanical methods for removal of demineralized dentin. A total of thirty sound human third molars indicated for extraction. After extraction, the teeth were cleaned and stored properly. The occlusal enamel was removed with a diamond wheel to expose a flat dentin surface, and each tooth was sectioned longitudinally in the buccal-lingual direction. One half of each tooth was entirely covered with an acid-resistant varnish, except for an occlusal area of 16 mm2, and was submitted to pH-cycling model to produce demineralized dentin. The other half of each tooth was maintained with mineralized dentin. The pH-cycling procedure was taken in 8 days. Halves of teeth were reassembled with cyanoacrylate adhesive. Samples were randomly allocated into three groups according to the method of removal of demineralized dentin: G1 â steel bur, G2 â polymer bur; G3 â hand excavation. The procedure of demineralized dentin removal was performed by a single operator. Digital images were obtained and cavities depths were measured (Âm) using MacBiophotonics ImageJ software. Knoop microhardness measurements (kgf/mm2) were performed in all samples at 10 to 200 Âm depth from the bottom of cavities. Data for cavity depth and microhardness were analyzed using One-Way ANOVA and the post hoc tests (p<0.05). The steel bur provided a larger wear, resulting in a deeper depth after the removal of the demineralized dentin, followed by the hand excavator and the polymer bur had a lower depth. The hardness values obtained with the steel bur were higher, indicating that there was a higher standard of demineralized dentin removal, followed by the hand excavator. The use of polymer bur left dentin with low values of hardness, indicating that demineralized tissue still remained. The polymer bur looks to be more selective in the removal of the demineralized dentin when compared with the steel bur and the hand excavator.
O objetivo do estudo foi avaliar a efetividade de trÃs mÃtodos mecÃnicos na remoÃÃo de dentina desmineralizada. Utilizaram-se 30 terceiros molares humanos hÃgidos, indicados para extraÃÃo. ApÃs a extraÃÃo, os dentes foram devidamente limpos e armazenados. Removeu-se o esmalte oclusal com um disco de diamante para expor uma superfÃcie plana de dentina e seccionou-se cada dente longitudinalmente, no sentido vestÃbulo-lingual. Uma metade de cada dente foi totalmente coberta com um verniz Ãcido resistente, com exceÃÃo de uma Ãrea oclusal de 16 mm2, e submetida à ciclagem de pH para produzir dentina desmineralizada. A outra metade de cada dente foi mantida com a dentina mineralizada. A dentina desmineralizada foi criada por meio de procedimento de ciclagem de pH durante 8 dias. As metades dos dentes foram unidas novamente com adesivo de cianoacrilato. Alocaram-se aleatoriamente as amostras em trÃs grupos, segundo o mÃtodo de remoÃÃo da dentina desmineralizada: G1 â broca de aÃo esfÃrica; G2 â broca de polÃmero; G3 â cureta de dentina. Um Ãnico operador realizou o procedimento de remoÃÃo de dentina desmineralizada. ApÃs a remoÃÃo da dentina, as metades dos dentes foram separadas, incluÃdos em resina acrÃlica e polidas. As imagens digitais foram obtidas e as profundidades das cavidades foram medidas (Âm) com o uso do programa MacBiophotonics ImageJ. Realizaram-se medidas de dureza Knoop (kgf/mm2) em todas as amostras de 10 a 200 microns a partir do fundo das cavidades. Os dados de profundidade da cavidade e microdureza foram analisados utilizando One-Way ANOVA e os testes post hoc (p<0,05). A broca de aÃo proporcionou um maior desgaste, resultando em uma maior profundidade apÃs a remoÃÃo da dentina desmineralizada, seguida da cureta de dentina, e a broca de polÃmero teve uma menor profundidade. Os valores de dureza obtidos com o emprego da broca de aÃo foram maiores, o que indica que houve um padrÃo maior de remoÃÃo de dentina desmineralizada, seguidos dos valores da cureta de dentina, enquanto a broca de polÃmero apresentou nÃmeros menores de dureza, apontando ainda a presenÃa de tecido desmineralizado. A broca de polÃmero parece ser mais seletiva na remoÃÃo da dentina desmineralizada, quando comparada com a broca de aÃo e a cureta de dentina.
description The aim of this study was to evaluate the effectiveness of three mechanical methods for removal of demineralized dentin. A total of thirty sound human third molars indicated for extraction. After extraction, the teeth were cleaned and stored properly. The occlusal enamel was removed with a diamond wheel to expose a flat dentin surface, and each tooth was sectioned longitudinally in the buccal-lingual direction. One half of each tooth was entirely covered with an acid-resistant varnish, except for an occlusal area of 16 mm2, and was submitted to pH-cycling model to produce demineralized dentin. The other half of each tooth was maintained with mineralized dentin. The pH-cycling procedure was taken in 8 days. Halves of teeth were reassembled with cyanoacrylate adhesive. Samples were randomly allocated into three groups according to the method of removal of demineralized dentin: G1 â steel bur, G2 â polymer bur; G3 â hand excavation. The procedure of demineralized dentin removal was performed by a single operator. Digital images were obtained and cavities depths were measured (Âm) using MacBiophotonics ImageJ software. Knoop microhardness measurements (kgf/mm2) were performed in all samples at 10 to 200 Âm depth from the bottom of cavities. Data for cavity depth and microhardness were analyzed using One-Way ANOVA and the post hoc tests (p<0.05). The steel bur provided a larger wear, resulting in a deeper depth after the removal of the demineralized dentin, followed by the hand excavator and the polymer bur had a lower depth. The hardness values obtained with the steel bur were higher, indicating that there was a higher standard of demineralized dentin removal, followed by the hand excavator. The use of polymer bur left dentin with low values of hardness, indicating that demineralized tissue still remained. The polymer bur looks to be more selective in the removal of the demineralized dentin when compared with the steel bur and the hand excavator.
publishDate 2012
dc.date.issued.fl_str_mv 2012-08-31
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
status_str publishedVersion
format masterThesis
dc.identifier.uri.fl_str_mv http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=8882
url http://www.teses.ufc.br/tde_busca/arquivo.php?codArquivo=8882
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal do CearÃ
dc.publisher.program.fl_str_mv Programa de PÃs-GraduaÃÃo em Odontologia
dc.publisher.initials.fl_str_mv UFC
dc.publisher.country.fl_str_mv BR
publisher.none.fl_str_mv Universidade Federal do CearÃ
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UFC
instname:Universidade Federal do Ceará
instacron:UFC
reponame_str Biblioteca Digital de Teses e Dissertações da UFC
collection Biblioteca Digital de Teses e Dissertações da UFC
instname_str Universidade Federal do Ceará
instacron_str UFC
institution UFC
repository.name.fl_str_mv -
repository.mail.fl_str_mv mail@mail.com
_version_ 1643295168206471168