Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone model

Detalhes bibliográficos
Autor(a) principal: Prada,T.C.
Data de Publicação: 2017
Outros Autores: Shimano,A.C., Chung,D., Karcher,D.E., Minto,B.W.
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Arquivo brasileiro de medicina veterinária e zootecnia (Online)
Texto Completo: http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352017000400901
Resumo: ABSTRACT Pelvic fractures correspond to 20 to 30 % of the fractures observed in dogs. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques is of utmost importance to assess the best way of treating these injuries. This study compared, biomechanically, the use of a dynamic compression plate (DCP) and screws (group 1) or screws and polymethylmethacrylate (PMMA) (group 2) to stabilize an iliac fracture using a static test. Sixteen canine synthetic hemi-pelvises (test specimens) with a transverse iliac osteotomy were used. After fixation with implants, a load was applied to the acetabulum until failure. Group 1 maximal compressive load was 133.9±18.60 N, displacement at yield 21.10±3.59mm and stiffness 125.22±12.25N/mm. Group 2 maximal compressive load was 183.50±27.38N, displacement at yield 16.66±5.42mm and stiffness 215.68±33.34N/mm. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate since it resisted a greater load in all test specimens.
id UFMG-8_d1793b144b4bfcace42bfd25eee6848d
oai_identifier_str oai:scielo:S0102-09352017000400901
network_acronym_str UFMG-8
network_name_str Arquivo brasileiro de medicina veterinária e zootecnia (Online)
repository_id_str
spelling Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone modelpelvisstabilizationbiomechanicalfractureABSTRACT Pelvic fractures correspond to 20 to 30 % of the fractures observed in dogs. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques is of utmost importance to assess the best way of treating these injuries. This study compared, biomechanically, the use of a dynamic compression plate (DCP) and screws (group 1) or screws and polymethylmethacrylate (PMMA) (group 2) to stabilize an iliac fracture using a static test. Sixteen canine synthetic hemi-pelvises (test specimens) with a transverse iliac osteotomy were used. After fixation with implants, a load was applied to the acetabulum until failure. Group 1 maximal compressive load was 133.9±18.60 N, displacement at yield 21.10±3.59mm and stiffness 125.22±12.25N/mm. Group 2 maximal compressive load was 183.50±27.38N, displacement at yield 16.66±5.42mm and stiffness 215.68±33.34N/mm. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate since it resisted a greater load in all test specimens.Universidade Federal de Minas Gerais, Escola de Veterinária2017-08-01info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersiontext/htmlhttp://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352017000400901Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.69 n.4 2017reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online)instname:Universidade Federal de Minas Gerais (UFMG)instacron:UFMG10.1590/1678-4162-8434info:eu-repo/semantics/openAccessPrada,T.C.Shimano,A.C.Chung,D.Karcher,D.E.Minto,B.W.eng2017-09-06T00:00:00Zoai:scielo:S0102-09352017000400901Revistahttps://www.scielo.br/j/abmvz/PUBhttps://old.scielo.br/oai/scielo-oai.phpjournal@vet.ufmg.br||abmvz.artigo@abmvz.org.br1678-41620102-0935opendoar:2017-09-06T00:00Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG)false
dc.title.none.fl_str_mv Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone model
title Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone model
spellingShingle Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone model
Prada,T.C.
pelvis
stabilization
biomechanical
fracture
title_short Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone model
title_full Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone model
title_fullStr Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone model
title_full_unstemmed Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone model
title_sort Mechanical analysis of transversal iliac fracture stabilization using dynamic compression plate or screws and PMM in polyurethane bone model
author Prada,T.C.
author_facet Prada,T.C.
Shimano,A.C.
Chung,D.
Karcher,D.E.
Minto,B.W.
author_role author
author2 Shimano,A.C.
Chung,D.
Karcher,D.E.
Minto,B.W.
author2_role author
author
author
author
dc.contributor.author.fl_str_mv Prada,T.C.
Shimano,A.C.
Chung,D.
Karcher,D.E.
Minto,B.W.
dc.subject.por.fl_str_mv pelvis
stabilization
biomechanical
fracture
topic pelvis
stabilization
biomechanical
fracture
description ABSTRACT Pelvic fractures correspond to 20 to 30 % of the fractures observed in dogs. Complete fractures, especially with bone axis deviation should be surgically treated. The mechanical study of surgical techniques is of utmost importance to assess the best way of treating these injuries. This study compared, biomechanically, the use of a dynamic compression plate (DCP) and screws (group 1) or screws and polymethylmethacrylate (PMMA) (group 2) to stabilize an iliac fracture using a static test. Sixteen canine synthetic hemi-pelvises (test specimens) with a transverse iliac osteotomy were used. After fixation with implants, a load was applied to the acetabulum until failure. Group 1 maximal compressive load was 133.9±18.60 N, displacement at yield 21.10±3.59mm and stiffness 125.22±12.25N/mm. Group 2 maximal compressive load was 183.50±27.38N, displacement at yield 16.66±5.42mm and stiffness 215.68±33.34N/mm. The stabilization with polymethylmethacrylate was stronger than dynamic compression plate since it resisted a greater load in all test specimens.
publishDate 2017
dc.date.none.fl_str_mv 2017-08-01
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352017000400901
url http://old.scielo.br/scielo.php?script=sci_arttext&pid=S0102-09352017000400901
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv 10.1590/1678-4162-8434
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv text/html
dc.publisher.none.fl_str_mv Universidade Federal de Minas Gerais, Escola de Veterinária
publisher.none.fl_str_mv Universidade Federal de Minas Gerais, Escola de Veterinária
dc.source.none.fl_str_mv Arquivo Brasileiro de Medicina Veterinária e Zootecnia v.69 n.4 2017
reponame:Arquivo brasileiro de medicina veterinária e zootecnia (Online)
instname:Universidade Federal de Minas Gerais (UFMG)
instacron:UFMG
instname_str Universidade Federal de Minas Gerais (UFMG)
instacron_str UFMG
institution UFMG
reponame_str Arquivo brasileiro de medicina veterinária e zootecnia (Online)
collection Arquivo brasileiro de medicina veterinária e zootecnia (Online)
repository.name.fl_str_mv Arquivo brasileiro de medicina veterinária e zootecnia (Online) - Universidade Federal de Minas Gerais (UFMG)
repository.mail.fl_str_mv journal@vet.ufmg.br||abmvz.artigo@abmvz.org.br
_version_ 1750220890911539200