Sistemas fotovoltaicos conectados a redes de distribuição urbanas: sua influência na qualidade da energia elétrica e análise dos parâmetros que possam afetar a conectividade

Detalhes bibliográficos
Autor(a) principal: Urbanetz Junior, Jair
Data de Publicação: 2012
Tipo de documento: Tese
Idioma: por
Título da fonte: Repositório Institucional da UFSC
Texto Completo: http://repositorio.ufsc.br/xmlui/handle/123456789/94284
Resumo: Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2010
id UFSC_2e0ce46a418a54710c6e681fb0c8da69
oai_identifier_str oai:repositorio.ufsc.br:123456789/94284
network_acronym_str UFSC
network_name_str Repositório Institucional da UFSC
repository_id_str 2373
spelling Universidade Federal de Santa CatarinaUrbanetz Junior, JairRüther, Ricardo2012-10-25T08:18:40Z2012-10-25T08:18:40Z2012-10-25T08:18:40Z282788http://repositorio.ufsc.br/xmlui/handle/123456789/94284Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2010Este trabalho aborda a interação entre os inversores de sistemas fotovoltaicos conectados à rede elétrica (SFCR) e a qualidade da energia elétrica. Os inversores, ao entregarem energia à rede, injetam uma forma de onda de corrente que teoricamente deveria ser puramente senoidal, mas, dependendo do inversor e do percentual de potência que está sendo processado em relação a sua potência nominal, esta corrente apresenta certo grau de distorção. Por outro lado, a rede pública de baixa tensão deve possuir um grau de qualidade na energia elétrica que permita o funcionamento dos inversores de SFCR. Estes inversores monitoram a rede elétrica de forma a somente fornecer energia se a rede estiver presente e com suas características padrão. Devido à pouca quantidade de SFCR no Brasil, e por grande parte desses sistemas estarem instalados em universidades e centros de pesquisa, poucos problemas com a qualidade de energia são relatados. Nesses ambientes, diferente do ambiente industrial, existe menor tendência da energia elétrica possuir elevado conteúdo harmônico. Entre os projetos de SFCR que o Laboratório de Energia Solar (LABSOLAR) da Universidade Federal de Santa Catarina (UFSC) desenvolveu e implantou desde 1997, um sistema de 14,69 kWp instalado em 2008 em uma indústria metalúrgica de São Bernardo do Campo - SP, apresentou problemas na conexão do sistema devido à baixa qualidade da energia elétrica da rede. Este fato motivou uma investigação mais profunda sobre a interrelação entre a qualidade da energia elétrica e o desempenho de inversores de SFCR. O baixo grau de exigência quanto às características técnicas em aparelhos eletro-eletrônicos em operação no Brasil contribui para que a qualidade de energia elétrica seja prejudicada. Baixo fator de potência, elevado conteúdo harmônico, elevada interferência eletromagnética (irradiada e/ou conduzida) são fatores que afetam significativamente a qualidade da energia elétrica no Brasil, diferente do que ocorre em países europeus onde normas rigorosas são impostas aos aparelhos eletro-eletrônicos em uso nestas localidades, permitindo um bom desempenho da rede elétrica. Este estudo apresenta a necessidade de se conhecer a qualidade da energia no ponto onde se deseja fazer a conexão de um sistema fotovoltaico, visto que isto passa a ser mais um quesito a ser considerado durante o anteprojeto de um SFCR. Por outro lado, após a implantação de um gerador fotovoltaico, dependendo da magnitude desta instalação, a sua influência sobre os parâmetros de qualidade da energia elétrica da rede pública também deverá ser considerada. O método adotado nessa tese de verificar a qualidade da energia no ponto de conexão, de forma amostral, com o uso de um osciloscópio, mostrouse adequado. Ainda no âmbito dessa tese, foi analisada a capacidade de conexão dos inversores em redes elétricas formadas a partir de geradores a diesel de médio e grande porte, e também de gerador a gasolina de pequeno porte. Os resultados mostraram que a entrada em operação dos inversores de SFCR eleva a tensão e quase sempre provoca leve redução no conteúdo harmônico da tensão, levando a uma leve melhoria na qualidade da energia na grande maioria das medições realizadas. Observou-se nos ensaios realizados uma melhora na qualidade de energia no ponto de conexão dos sistemas fotovoltaicos. Verificaram-se também casos em que a baixa qualidade de energia da rede inviabilizou o funcionamento dos SFCR ou prejudicou seu desempenho, requerendo outras ações para viabilizar o funcionamento do SFCR. Buscar identificar fatores que possam vir a afetar o desempenho de SFCR no Brasil, bem como antecipar-se a esses fatores propondo soluções tecnológicas que permitam a conexão, é uma forma de contribuir para que o Brasil possa ingressar nesta forma de geração de energia com maiores perspectivas de sucesso.This work discusses the interaction between the inverters of grid connected PV systems and the resulting power quality. When inverters deliver energy to the grid, they inject a waveform which theoretically should be purely sinusoidal, but depending on the inverter and the percentage of power being processed in relation to its rated output, this current presents certain degree of distortion. On the other hand, the low voltage network must possess a degree of power quality to allow the operation of inverters. These inverters monitor the network so that they only provide energy if the grid is present and with its default characteristics. Because of the low quantity of grid connected PV systems operating in Brazil, and because a large fraction of these systems are installed at universities and research centers, few problems related to power quality are reported. In these environments, different from the industrial environment, there is less tendency of the electrical energy to present high harmonic content. Among the grid connected PV systems projects that LABSOLAR at University Federal of Santa Catarina (UFSC) developed and deployed since 1997, a system of 14.69 kWp installed in 2008 in a metallurgical industry in São Bernardo do Campo - SP, presented connection problems due to low power quality of the grid at the interconnection point. This fact led to an investigation of the interrelation between power quality and the inverters performance of the grid connected PV systems. The low level of technical characteristics requirement for electronic devices in operation in Brazil contributes to a low power quality. Low power factor, high harmonic content, high radiated electromagnetic interference (irradiated and/or conducted) are factors that affect significantly the power quality in Brazil, unlike in European countries where strict standards are imposed to equipments used in these localities, allowing a good network performance. This study presents the need to know the power quality at the point where the connection of a PV system will be done, since this is one more aspect to be considered during the provisional draft of a grid connected PV system. On the other hand, after the connection of the PV generator, depending on the size of the installation, its influence on the power quality should also be considered. The method adopted in this thesis, to verify the power quality at the point of connection, using samples and an oscilloscope, was adequate. The connection capacity of the inverters in electrical grids formed from medium and large diesel generators, and also small gasoline generator was analyzed. The results showed that the operation of inverters SFCR elevates the tension and almost always causes a slight reduction in the harmonic content of voltage, leading to a slight improvement in power quality in the vast majority of measurements taken.It was observed that the power quality at the PV system connection point improved when compared with the original parameters before the PV system was introduced. However, there were situations where the low power quality of the local network either resulted in a reduced PV system performance, or altogether made impossible the operation of the grid connected PV system. To identify factors that may affect the performance of grid connected PV systems in Brazil, as well as to anticipate these factors and proposing technology solutions that allow the connection, is a way to contribute to the integration of this distributed, clean and renewable power generation source with greater prospects of success.189 p.| il., grafs., tabs.porEngenharia civilSistemas de energia eletricaInversores eletricosSistemas fotovoltaicos conectados a redes de distribuição urbanas: sua influência na qualidade da energia elétrica e análise dos parâmetros que possam afetar a conectividadeinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisreponame:Repositório Institucional da UFSCinstname:Universidade Federal de Santa Catarina (UFSC)instacron:UFSCinfo:eu-repo/semantics/openAccessORIGINAL282788.pdfapplication/pdf11318990https://repositorio.ufsc.br/bitstream/123456789/94284/1/282788.pdf91dc56195c3f49876322336934efa206MD51TEXT282788.pdf.txt282788.pdf.txtExtracted Texttext/plain269081https://repositorio.ufsc.br/bitstream/123456789/94284/2/282788.pdf.txt38cc6ca6cd5dab9db39239d3713473d4MD52THUMBNAIL282788.pdf.jpg282788.pdf.jpgGenerated Thumbnailimage/jpeg1231https://repositorio.ufsc.br/bitstream/123456789/94284/3/282788.pdf.jpgd095538d0a53b9d8269db61acb984b85MD53123456789/942842013-05-03 11:24:35.268oai:repositorio.ufsc.br:123456789/94284Repositório de PublicaçõesPUBhttp://150.162.242.35/oai/requestopendoar:23732013-05-03T14:24:35Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)false
dc.title.pt_BR.fl_str_mv Sistemas fotovoltaicos conectados a redes de distribuição urbanas: sua influência na qualidade da energia elétrica e análise dos parâmetros que possam afetar a conectividade
title Sistemas fotovoltaicos conectados a redes de distribuição urbanas: sua influência na qualidade da energia elétrica e análise dos parâmetros que possam afetar a conectividade
spellingShingle Sistemas fotovoltaicos conectados a redes de distribuição urbanas: sua influência na qualidade da energia elétrica e análise dos parâmetros que possam afetar a conectividade
Urbanetz Junior, Jair
Engenharia civil
Sistemas de energia eletrica
Inversores eletricos
title_short Sistemas fotovoltaicos conectados a redes de distribuição urbanas: sua influência na qualidade da energia elétrica e análise dos parâmetros que possam afetar a conectividade
title_full Sistemas fotovoltaicos conectados a redes de distribuição urbanas: sua influência na qualidade da energia elétrica e análise dos parâmetros que possam afetar a conectividade
title_fullStr Sistemas fotovoltaicos conectados a redes de distribuição urbanas: sua influência na qualidade da energia elétrica e análise dos parâmetros que possam afetar a conectividade
title_full_unstemmed Sistemas fotovoltaicos conectados a redes de distribuição urbanas: sua influência na qualidade da energia elétrica e análise dos parâmetros que possam afetar a conectividade
title_sort Sistemas fotovoltaicos conectados a redes de distribuição urbanas: sua influência na qualidade da energia elétrica e análise dos parâmetros que possam afetar a conectividade
author Urbanetz Junior, Jair
author_facet Urbanetz Junior, Jair
author_role author
dc.contributor.pt_BR.fl_str_mv Universidade Federal de Santa Catarina
dc.contributor.author.fl_str_mv Urbanetz Junior, Jair
dc.contributor.advisor1.fl_str_mv Rüther, Ricardo
contributor_str_mv Rüther, Ricardo
dc.subject.classification.pt_BR.fl_str_mv Engenharia civil
Sistemas de energia eletrica
Inversores eletricos
topic Engenharia civil
Sistemas de energia eletrica
Inversores eletricos
description Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Civil, Florianópolis, 2010
publishDate 2012
dc.date.accessioned.fl_str_mv 2012-10-25T08:18:40Z
dc.date.available.fl_str_mv 2012-10-25T08:18:40Z
dc.date.issued.fl_str_mv 2012-10-25T08:18:40Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://repositorio.ufsc.br/xmlui/handle/123456789/94284
dc.identifier.other.pt_BR.fl_str_mv 282788
identifier_str_mv 282788
url http://repositorio.ufsc.br/xmlui/handle/123456789/94284
dc.language.iso.fl_str_mv por
language por
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 189 p.| il., grafs., tabs.
dc.source.none.fl_str_mv reponame:Repositório Institucional da UFSC
instname:Universidade Federal de Santa Catarina (UFSC)
instacron:UFSC
instname_str Universidade Federal de Santa Catarina (UFSC)
instacron_str UFSC
institution UFSC
reponame_str Repositório Institucional da UFSC
collection Repositório Institucional da UFSC
bitstream.url.fl_str_mv https://repositorio.ufsc.br/bitstream/123456789/94284/1/282788.pdf
https://repositorio.ufsc.br/bitstream/123456789/94284/2/282788.pdf.txt
https://repositorio.ufsc.br/bitstream/123456789/94284/3/282788.pdf.jpg
bitstream.checksum.fl_str_mv 91dc56195c3f49876322336934efa206
38cc6ca6cd5dab9db39239d3713473d4
d095538d0a53b9d8269db61acb984b85
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Repositório Institucional da UFSC - Universidade Federal de Santa Catarina (UFSC)
repository.mail.fl_str_mv
_version_ 1766805355817336832