Pressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758)

Detalhes bibliográficos
Autor(a) principal: Gonçalves, Gentil Ferreira
Data de Publicação: 2005
Tipo de documento: Tese
Idioma: por
Título da fonte: Manancial - Repositório Digital da UFSM
Texto Completo: http://repositorio.ufsm.br/handle/1/4022
Resumo: Veterinary medicine is benefitted by technological advances in diagnostic area by the spreading of scientific knowlagement. In order that new technologies may be used, information about normal standards for each type of examination is necessary, so that they may be used routinely and adequately prescribed for each patient. The Doppler ultrasound is beginning to be used in veterinary medicine for diverse purposes. The objectives of this study were to verify the Doppler ultrasound flow of the external ophthalmic artery in mixed breed cats anesthetized with tiletamine and zolazepam, and to correlate the average mean arterial pressure (MAP) surveyed by direct method in the same animals. There were used 20 mixed breed cats, both male and female, with body mass between 2 and 4 kilograms, proceeding from the Sociedade de Auxílio aos Animais de Umuarama - PR (SAAU). The animals received intra-muscular anesthesia with tiletamine and zolazepam (6,0 mg/kg). The femoral artery was assepticale cannulated and a manometer connected to an air column was connected to the catheter. The MAP was surveyed before and every 15 minutes until the end of the ultrasound examination. The flow of the external ophthalmic artery was measured through the ultrasond equipment Toshiba Powervision ATLHDI 3500, with an echo-doppler and a sectorial transducer of 6.0 MHz, directly applied to the cornea. Each eye had the artery flow surveyed by the equipment s own device, 3 samples being taken. The vascular resistance index was calculated based on the mean values of systolic and diastolic flow of each vasses. The values were tabulated and Student t test was applied to verify differences between the averages. Test of logistic regression was applied to the values of the MAP and the means of the artery flow to verify the correlation between the surveyed values. An average value for the MAP of 144.9 ± 26.68 mmHg and a flow of 14.28 ± 41.3 cm/sec for the external ophthalmic artery in the right eye in systole, 23.95 ± 11.46 cm/sec in diastole and 42.75 ± 12.64 cm/sec in the left eye in systole, 25.45 ± 9.61 cm/sec in diastole, were verified, there being no significant difference between the eyes. Correlation was not evidenced between the values of the MAP and the blood flow in the ophthalmic artery in both the eyes. The calculated index of vascular resistance was of 0.4175 ± 0.0774 for the external ophthalmic artery in the right eye and 0,4015 ± 0.0719 for the left eye, without any significant difference between the eyes. The results point to an intrinsic mechanism of flow control, controlled by local factors in the external ophthalmic artery. The values of the resistance index denote a low flow artery. Concluding, this study revealed the reference values, above cited, for the MAP and the blood flow in the external ophthalmic artery in mixed breed cats, anesthetized with tiletamine and zolazepam, and the information that there is no correlation between these values.
id UFSM-20_c7266273d1ba556e14a1313d9b1a4cfc
oai_identifier_str oai:repositorio.ufsm.br:1/4022
network_acronym_str UFSM-20
network_name_str Manancial - Repositório Digital da UFSM
repository_id_str 3913
spelling 2017-06-062017-06-062005-02-21GONÇALVES, Gentil Ferreira. Arterial pressure and blood flow in the external ophthalmic artery in cats (Felis catus, Linnaeus, 1758). 2005. 80 f. Tese (Doutorado em Medicina Veterinária) - Universidade Federal de Santa Maria, Santa Maria, 2005.http://repositorio.ufsm.br/handle/1/4022Veterinary medicine is benefitted by technological advances in diagnostic area by the spreading of scientific knowlagement. In order that new technologies may be used, information about normal standards for each type of examination is necessary, so that they may be used routinely and adequately prescribed for each patient. The Doppler ultrasound is beginning to be used in veterinary medicine for diverse purposes. The objectives of this study were to verify the Doppler ultrasound flow of the external ophthalmic artery in mixed breed cats anesthetized with tiletamine and zolazepam, and to correlate the average mean arterial pressure (MAP) surveyed by direct method in the same animals. There were used 20 mixed breed cats, both male and female, with body mass between 2 and 4 kilograms, proceeding from the Sociedade de Auxílio aos Animais de Umuarama - PR (SAAU). The animals received intra-muscular anesthesia with tiletamine and zolazepam (6,0 mg/kg). The femoral artery was assepticale cannulated and a manometer connected to an air column was connected to the catheter. The MAP was surveyed before and every 15 minutes until the end of the ultrasound examination. The flow of the external ophthalmic artery was measured through the ultrasond equipment Toshiba Powervision ATLHDI 3500, with an echo-doppler and a sectorial transducer of 6.0 MHz, directly applied to the cornea. Each eye had the artery flow surveyed by the equipment s own device, 3 samples being taken. The vascular resistance index was calculated based on the mean values of systolic and diastolic flow of each vasses. The values were tabulated and Student t test was applied to verify differences between the averages. Test of logistic regression was applied to the values of the MAP and the means of the artery flow to verify the correlation between the surveyed values. An average value for the MAP of 144.9 ± 26.68 mmHg and a flow of 14.28 ± 41.3 cm/sec for the external ophthalmic artery in the right eye in systole, 23.95 ± 11.46 cm/sec in diastole and 42.75 ± 12.64 cm/sec in the left eye in systole, 25.45 ± 9.61 cm/sec in diastole, were verified, there being no significant difference between the eyes. Correlation was not evidenced between the values of the MAP and the blood flow in the ophthalmic artery in both the eyes. The calculated index of vascular resistance was of 0.4175 ± 0.0774 for the external ophthalmic artery in the right eye and 0,4015 ± 0.0719 for the left eye, without any significant difference between the eyes. The results point to an intrinsic mechanism of flow control, controlled by local factors in the external ophthalmic artery. The values of the resistance index denote a low flow artery. Concluding, this study revealed the reference values, above cited, for the MAP and the blood flow in the external ophthalmic artery in mixed breed cats, anesthetized with tiletamine and zolazepam, and the information that there is no correlation between these values.A medicina veterinária vem se beneficiando dos avanços tecnológicos dos meios diagnósticos em medicina, e da facilitação da divulgação da ciência. Para que novas tecnologias sejam utilizadas são necessárias informações acerca dos padrões normais para cada tipo de exame, para que se possa utilizá-lo na rotina e destiná-lo adequadamente para cada paciente. A fluxometria ultra-sonográfica está começando a ser utilizada em medicina veterinária com propósitos e fins diversos. Para destiná-la a um fim específico, o presente trabalho teve por objetivos verificar a fluxometria ultra-sonográfica da artéria oftálmica externa em gatos sem raça definida e anestesiados com tiletamina e zolazepam, e correlacioná-la à pressão arterial média aferida por método direto. Para tanto foram utilizados 20 gatos sem raça definida, entre machos e fêmeas, com massa corpórea entre 2 e 4 quilogramas, hígidos, provenientes da Sociedade de Amparo aos Animais de Umuarama - PR (SAAU). Os animais receberam anestesia intramuscular com tiletamina e zolazepam na dose de 6,0 mg/kg. A artéria femoral foi canulada de forma asséptica e um manômetro acoplado a uma coluna de ar foi conectada ao cateter, a PAM foi aferida antes e a cada 15 minutos até o término do exame ultra-sonográfico. A fluxometria da artéria oftálmica externa foi obtida através do equipamento de ultra-sonografia Toshiba Powervision ATL-HDI 3500, dotado de eco-doppler, com transdutor setorial de 6,0 MHz, aplicado diretamente sobre a córnea. Cada olho teve o fluxo de sua artéria aferido pelo programa do próprio aparelho, sendo tomadas 3 amostras. O índice de resistência vascular foi calculado com base nos valores do fluxo sistólico e diastólico médio de cada vaso. Os valores foram tabulados e teste t de Student foi aplicado para verificação de diferenças entre as médias. Teste de regressão logística foi aplicado aos valores da PAM e aos do fluxo em cada artéria, para verificar a existência de correlação entre os valores aferidos. Obteve-se um valor médio para a PAM de 144,9 ± 26,68 mmHg e uma velocidade de fluxo de 41,3 ± 14,28 cm/seg para a artéria oftálmica externa no olho direito em sístole, 23,95 ± 11,46 cm/seg em diástole e 42,75 ± 12,64 cm/seg no olho esquerdo em sístole, 25,45 ± 9,61 cm/seg em diástole, não existindo diferença significativa entre os olhos. Não foi constatada correlação entre os valores da PAM e o fluxo sangüíneo na artéria oftálmica em nenhum dos olhos. O índice de resistência vascular calculado foi de 0,4175 para a artéria oftálmica externa no olho direito e 0,4015 para a do olho esquerdo, sem diferença significativa entre os olhos. Os resultados apontam para um mecanismo intrínseco de controle do fluxo, controlado por fatores locais na artéria oftálmica externa. Os valores do índice de resistência denotam uma artéria de baixo fluxo. Como conclusão têm-se os valores de referência acima citados para a PAM e para o fluxo sangüíneo na artéria oftálmica externa em gatos sem raça definida anestesiados com tiletamina e zolazepam, e a informação de que não existe correlação entre esses valores.application/pdfporUniversidade Federal de Santa MariaPrograma de Pós-Graduação em Medicina VeterináriaUFSMBRMedicina VeterináriaGatosOftalmologiaPressão arterialFluxometriaArtéria oftálmicaCatOphthalmologyBlood pressureArterial flowOphthalmic arteryCNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIAPressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758)Arterial pressure and blood flow in the external ophthalmic artery in cats (Felis catus, Linnaeus, 1758)info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/doctoralThesisPippi, Ney Luishttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4783382P7Mazzanti, Alexandrehttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4795593E6Rossi, Alvaro Garciahttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4784143D7Godoy, Carmen Lice Buchmann dehttp://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4790150U6http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4708639A3Gonçalves, Gentil Ferreira500500000007400300300300300300e7d62db5-d9ba-4842-bf91-8dd7b40e28b152147a23-cc96-4fed-adcd-71801ab66b3f3ce7cb86-ac0f-4408-a772-84345155724fd6ebd605-0779-44b7-a05a-ab7a1f1b91f598ed7b5c-4820-4236-913d-a68dfba80dfainfo:eu-repo/semantics/openAccessreponame:Manancial - Repositório Digital da UFSMinstname:Universidade Federal de Santa Maria (UFSM)instacron:UFSMORIGINALGENTIL GONCALVES.PDFapplication/pdf10083504http://repositorio.ufsm.br/bitstream/1/4022/1/GENTIL%20GONCALVES.PDF19d6b3451c33d3b6e11d557d59a6c636MD51TEXTGENTIL GONCALVES.PDF.txtGENTIL GONCALVES.PDF.txtExtracted texttext/plain88190http://repositorio.ufsm.br/bitstream/1/4022/2/GENTIL%20GONCALVES.PDF.txtc8a72700d2e48f52ff2e94da93252a45MD52THUMBNAILGENTIL GONCALVES.PDF.jpgGENTIL GONCALVES.PDF.jpgIM Thumbnailimage/jpeg5159http://repositorio.ufsm.br/bitstream/1/4022/3/GENTIL%20GONCALVES.PDF.jpg4ea2f390f179344c4272162443d53c4cMD531/40222017-07-25 11:03:22.791oai:repositorio.ufsm.br:1/4022Repositório Institucionalhttp://repositorio.ufsm.br/PUBhttp://repositorio.ufsm.br/oai/requestopendoar:39132017-07-25T14:03:22Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)false
dc.title.por.fl_str_mv Pressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758)
dc.title.alternative.eng.fl_str_mv Arterial pressure and blood flow in the external ophthalmic artery in cats (Felis catus, Linnaeus, 1758)
title Pressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758)
spellingShingle Pressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758)
Gonçalves, Gentil Ferreira
Gatos
Oftalmologia
Pressão arterial
Fluxometria
Artéria oftálmica
Cat
Ophthalmology
Blood pressure
Arterial flow
Ophthalmic artery
CNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIA
title_short Pressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758)
title_full Pressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758)
title_fullStr Pressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758)
title_full_unstemmed Pressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758)
title_sort Pressão arterial média e o fluxo sangüíneo da artéria oftálmica externa em gatos (Felis catus Linnaeus, 1758)
author Gonçalves, Gentil Ferreira
author_facet Gonçalves, Gentil Ferreira
author_role author
dc.contributor.advisor1.fl_str_mv Pippi, Ney Luis
dc.contributor.advisor1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4783382P7
dc.contributor.referee1.fl_str_mv Mazzanti, Alexandre
dc.contributor.referee1Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4795593E6
dc.contributor.referee2.fl_str_mv Rossi, Alvaro Garcia
dc.contributor.referee2Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4784143D7
dc.contributor.referee3.fl_str_mv Godoy, Carmen Lice Buchmann de
dc.contributor.referee3Lattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4790150U6
dc.contributor.authorLattes.fl_str_mv http://buscatextual.cnpq.br/buscatextual/visualizacv.do?id=K4708639A3
dc.contributor.author.fl_str_mv Gonçalves, Gentil Ferreira
contributor_str_mv Pippi, Ney Luis
Mazzanti, Alexandre
Rossi, Alvaro Garcia
Godoy, Carmen Lice Buchmann de
dc.subject.por.fl_str_mv Gatos
Oftalmologia
Pressão arterial
Fluxometria
Artéria oftálmica
topic Gatos
Oftalmologia
Pressão arterial
Fluxometria
Artéria oftálmica
Cat
Ophthalmology
Blood pressure
Arterial flow
Ophthalmic artery
CNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIA
dc.subject.eng.fl_str_mv Cat
Ophthalmology
Blood pressure
Arterial flow
Ophthalmic artery
dc.subject.cnpq.fl_str_mv CNPQ::CIENCIAS AGRARIAS::MEDICINA VETERINARIA
description Veterinary medicine is benefitted by technological advances in diagnostic area by the spreading of scientific knowlagement. In order that new technologies may be used, information about normal standards for each type of examination is necessary, so that they may be used routinely and adequately prescribed for each patient. The Doppler ultrasound is beginning to be used in veterinary medicine for diverse purposes. The objectives of this study were to verify the Doppler ultrasound flow of the external ophthalmic artery in mixed breed cats anesthetized with tiletamine and zolazepam, and to correlate the average mean arterial pressure (MAP) surveyed by direct method in the same animals. There were used 20 mixed breed cats, both male and female, with body mass between 2 and 4 kilograms, proceeding from the Sociedade de Auxílio aos Animais de Umuarama - PR (SAAU). The animals received intra-muscular anesthesia with tiletamine and zolazepam (6,0 mg/kg). The femoral artery was assepticale cannulated and a manometer connected to an air column was connected to the catheter. The MAP was surveyed before and every 15 minutes until the end of the ultrasound examination. The flow of the external ophthalmic artery was measured through the ultrasond equipment Toshiba Powervision ATLHDI 3500, with an echo-doppler and a sectorial transducer of 6.0 MHz, directly applied to the cornea. Each eye had the artery flow surveyed by the equipment s own device, 3 samples being taken. The vascular resistance index was calculated based on the mean values of systolic and diastolic flow of each vasses. The values were tabulated and Student t test was applied to verify differences between the averages. Test of logistic regression was applied to the values of the MAP and the means of the artery flow to verify the correlation between the surveyed values. An average value for the MAP of 144.9 ± 26.68 mmHg and a flow of 14.28 ± 41.3 cm/sec for the external ophthalmic artery in the right eye in systole, 23.95 ± 11.46 cm/sec in diastole and 42.75 ± 12.64 cm/sec in the left eye in systole, 25.45 ± 9.61 cm/sec in diastole, were verified, there being no significant difference between the eyes. Correlation was not evidenced between the values of the MAP and the blood flow in the ophthalmic artery in both the eyes. The calculated index of vascular resistance was of 0.4175 ± 0.0774 for the external ophthalmic artery in the right eye and 0,4015 ± 0.0719 for the left eye, without any significant difference between the eyes. The results point to an intrinsic mechanism of flow control, controlled by local factors in the external ophthalmic artery. The values of the resistance index denote a low flow artery. Concluding, this study revealed the reference values, above cited, for the MAP and the blood flow in the external ophthalmic artery in mixed breed cats, anesthetized with tiletamine and zolazepam, and the information that there is no correlation between these values.
publishDate 2005
dc.date.issued.fl_str_mv 2005-02-21
dc.date.accessioned.fl_str_mv 2017-06-06
dc.date.available.fl_str_mv 2017-06-06
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/doctoralThesis
format doctoralThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv GONÇALVES, Gentil Ferreira. Arterial pressure and blood flow in the external ophthalmic artery in cats (Felis catus, Linnaeus, 1758). 2005. 80 f. Tese (Doutorado em Medicina Veterinária) - Universidade Federal de Santa Maria, Santa Maria, 2005.
dc.identifier.uri.fl_str_mv http://repositorio.ufsm.br/handle/1/4022
identifier_str_mv GONÇALVES, Gentil Ferreira. Arterial pressure and blood flow in the external ophthalmic artery in cats (Felis catus, Linnaeus, 1758). 2005. 80 f. Tese (Doutorado em Medicina Veterinária) - Universidade Federal de Santa Maria, Santa Maria, 2005.
url http://repositorio.ufsm.br/handle/1/4022
dc.language.iso.fl_str_mv por
language por
dc.relation.cnpq.fl_str_mv 500500000007
dc.relation.confidence.fl_str_mv 400
300
300
300
300
300
dc.relation.authority.fl_str_mv e7d62db5-d9ba-4842-bf91-8dd7b40e28b1
52147a23-cc96-4fed-adcd-71801ab66b3f
3ce7cb86-ac0f-4408-a772-84345155724f
d6ebd605-0779-44b7-a05a-ab7a1f1b91f5
98ed7b5c-4820-4236-913d-a68dfba80dfa
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade Federal de Santa Maria
dc.publisher.program.fl_str_mv Programa de Pós-Graduação em Medicina Veterinária
dc.publisher.initials.fl_str_mv UFSM
dc.publisher.country.fl_str_mv BR
dc.publisher.department.fl_str_mv Medicina Veterinária
publisher.none.fl_str_mv Universidade Federal de Santa Maria
dc.source.none.fl_str_mv reponame:Manancial - Repositório Digital da UFSM
instname:Universidade Federal de Santa Maria (UFSM)
instacron:UFSM
instname_str Universidade Federal de Santa Maria (UFSM)
instacron_str UFSM
institution UFSM
reponame_str Manancial - Repositório Digital da UFSM
collection Manancial - Repositório Digital da UFSM
bitstream.url.fl_str_mv http://repositorio.ufsm.br/bitstream/1/4022/1/GENTIL%20GONCALVES.PDF
http://repositorio.ufsm.br/bitstream/1/4022/2/GENTIL%20GONCALVES.PDF.txt
http://repositorio.ufsm.br/bitstream/1/4022/3/GENTIL%20GONCALVES.PDF.jpg
bitstream.checksum.fl_str_mv 19d6b3451c33d3b6e11d557d59a6c636
c8a72700d2e48f52ff2e94da93252a45
4ea2f390f179344c4272162443d53c4c
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Manancial - Repositório Digital da UFSM - Universidade Federal de Santa Maria (UFSM)
repository.mail.fl_str_mv
_version_ 1794523862563553280