Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis

Bibliographic Details
Main Author: Gomes, Grazielle Franco
Publication Date: 2023
Other Authors: Tinajero Aroni, Mónica Estefanía, Oliveira, Lucas Portela, Arioli Filho, João Neudenir, Binda, Carolina Mollo, Mollo Júnior, Francisco de Assis
Format: Article
Language: eng
Source: Brazilian journal of oral sciences (Online)
Download full: https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8668354
Summary: Aim: To analyze the accuracy of extraoral systems (Ceramill Map400+, AutoScan-DS200+, and E2) in full implantprosthetic rehabilitation three-dimensionally. Methods: A metallic edentulous maxilla with four implants was digitalized by a contact scanner (MDX-40 - Roland, control) and used as a control image to compare with other images generated by three laboratory scanners (10 samples per group). Letters identified all the four components: A and D angled 45º, and B and C parallel. The BioCAD software exported the images (.STL) to compare and verify deviations of the analogs on the X, Y, and Z axes. The nonparametric Kruskal-Wallis test and the two-way ANOVA on ranks with a post hoc Tukey test analyzed the data with 5% significance. Results: No statistical differences were observed in the accuracy between the extraoral scanners (p=0.0806). However, when analyzing only the components, component D was more accurate when scanned with Ceramill Map400+ compared with AutoScan DS200+ (p<0.001) and with E2 (p=0.002). Conclusions: All extraoral systems assessed showed digitalization accuracy but with more deviations in angled implants. The Ceramill Map400+ scanner showed the best results for the digital impression of a complete arch.
id UNICAMP-8_85dd4391506f7c0a8098ebc8bc7953b3
oai_identifier_str oai:ojs.periodicos.sbu.unicamp.br:article/8668354
network_acronym_str UNICAMP-8
network_name_str Brazilian journal of oral sciences (Online)
repository_id_str
spelling Implant digital impression accuracy using extraoral scanners: a three-dimensional analysisDental impression techniqueDental implantsDental prosthesisDental prosthesis, implant-supportedAim: To analyze the accuracy of extraoral systems (Ceramill Map400+, AutoScan-DS200+, and E2) in full implantprosthetic rehabilitation three-dimensionally. Methods: A metallic edentulous maxilla with four implants was digitalized by a contact scanner (MDX-40 - Roland, control) and used as a control image to compare with other images generated by three laboratory scanners (10 samples per group). Letters identified all the four components: A and D angled 45º, and B and C parallel. The BioCAD software exported the images (.STL) to compare and verify deviations of the analogs on the X, Y, and Z axes. The nonparametric Kruskal-Wallis test and the two-way ANOVA on ranks with a post hoc Tukey test analyzed the data with 5% significance. Results: No statistical differences were observed in the accuracy between the extraoral scanners (p=0.0806). However, when analyzing only the components, component D was more accurate when scanned with Ceramill Map400+ compared with AutoScan DS200+ (p<0.001) and with E2 (p=0.002). Conclusions: All extraoral systems assessed showed digitalization accuracy but with more deviations in angled implants. The Ceramill Map400+ scanner showed the best results for the digital impression of a complete arch.Universidade Estadual de Campinas2023-07-10info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/otherapplication/pdfhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/866835410.20396/bjos.v22i00.8668354Brazilian Journal of Oral Sciences; v. 22 (2023): Continuous Publication; e238354Brazilian Journal of Oral Sciences; Vol. 22 (2023): Continuous Publication; e2383541677-3225reponame:Brazilian journal of oral sciences (Online)instname:Universidade Estadual de Campinas (UNICAMP)instacron:UNICAMPenghttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8668354/32189Brazil; ContemporanyCopyright (c) 2022 Grazielle Franco Gomes, Mónica Estefanía Tinajero Aroni, Lucas Portela Oliveira, João Neudenir Arioli Filho, Carolina Mollo Binda, Francisco de Assis Mollo Júniorhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessGomes, Grazielle FrancoTinajero Aroni, Mónica EstefaníaOliveira, Lucas PortelaArioli Filho, João NeudenirBinda, Carolina MolloMollo Júnior, Francisco de Assis2023-07-12T13:22:22Zoai:ojs.periodicos.sbu.unicamp.br:article/8668354Revistahttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/PUBhttps://periodicos.sbu.unicamp.br/ojs/index.php/bjos/oaibrjorals@fop.unicamp.br||brjorals@fop.unicamp.br1677-32251677-3217opendoar:2023-07-12T13:22:22Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)false
dc.title.none.fl_str_mv Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis
title Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis
spellingShingle Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis
Gomes, Grazielle Franco
Dental impression technique
Dental implants
Dental prosthesis
Dental prosthesis, implant-supported
title_short Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis
title_full Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis
title_fullStr Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis
title_full_unstemmed Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis
title_sort Implant digital impression accuracy using extraoral scanners: a three-dimensional analysis
author Gomes, Grazielle Franco
author_facet Gomes, Grazielle Franco
Tinajero Aroni, Mónica Estefanía
Oliveira, Lucas Portela
Arioli Filho, João Neudenir
Binda, Carolina Mollo
Mollo Júnior, Francisco de Assis
author_role author
author2 Tinajero Aroni, Mónica Estefanía
Oliveira, Lucas Portela
Arioli Filho, João Neudenir
Binda, Carolina Mollo
Mollo Júnior, Francisco de Assis
author2_role author
author
author
author
author
dc.contributor.author.fl_str_mv Gomes, Grazielle Franco
Tinajero Aroni, Mónica Estefanía
Oliveira, Lucas Portela
Arioli Filho, João Neudenir
Binda, Carolina Mollo
Mollo Júnior, Francisco de Assis
dc.subject.por.fl_str_mv Dental impression technique
Dental implants
Dental prosthesis
Dental prosthesis, implant-supported
topic Dental impression technique
Dental implants
Dental prosthesis
Dental prosthesis, implant-supported
description Aim: To analyze the accuracy of extraoral systems (Ceramill Map400+, AutoScan-DS200+, and E2) in full implantprosthetic rehabilitation three-dimensionally. Methods: A metallic edentulous maxilla with four implants was digitalized by a contact scanner (MDX-40 - Roland, control) and used as a control image to compare with other images generated by three laboratory scanners (10 samples per group). Letters identified all the four components: A and D angled 45º, and B and C parallel. The BioCAD software exported the images (.STL) to compare and verify deviations of the analogs on the X, Y, and Z axes. The nonparametric Kruskal-Wallis test and the two-way ANOVA on ranks with a post hoc Tukey test analyzed the data with 5% significance. Results: No statistical differences were observed in the accuracy between the extraoral scanners (p=0.0806). However, when analyzing only the components, component D was more accurate when scanned with Ceramill Map400+ compared with AutoScan DS200+ (p<0.001) and with E2 (p=0.002). Conclusions: All extraoral systems assessed showed digitalization accuracy but with more deviations in angled implants. The Ceramill Map400+ scanner showed the best results for the digital impression of a complete arch.
publishDate 2023
dc.date.none.fl_str_mv 2023-07-10
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
info:eu-repo/semantics/other
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8668354
10.20396/bjos.v22i00.8668354
url https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8668354
identifier_str_mv 10.20396/bjos.v22i00.8668354
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://periodicos.sbu.unicamp.br/ojs/index.php/bjos/article/view/8668354/32189
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.coverage.none.fl_str_mv Brazil; Contemporany
dc.publisher.none.fl_str_mv Universidade Estadual de Campinas
publisher.none.fl_str_mv Universidade Estadual de Campinas
dc.source.none.fl_str_mv Brazilian Journal of Oral Sciences; v. 22 (2023): Continuous Publication; e238354
Brazilian Journal of Oral Sciences; Vol. 22 (2023): Continuous Publication; e238354
1677-3225
reponame:Brazilian journal of oral sciences (Online)
instname:Universidade Estadual de Campinas (UNICAMP)
instacron:UNICAMP
instname_str Universidade Estadual de Campinas (UNICAMP)
instacron_str UNICAMP
institution UNICAMP
reponame_str Brazilian journal of oral sciences (Online)
collection Brazilian journal of oral sciences (Online)
repository.name.fl_str_mv Brazilian journal of oral sciences (Online) - Universidade Estadual de Campinas (UNICAMP)
repository.mail.fl_str_mv brjorals@fop.unicamp.br||brjorals@fop.unicamp.br
_version_ 1800216404101693440