The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method

Detalhes bibliográficos
Autor(a) principal: Franco, Aline Batista Gonçalves
Data de Publicação: 2022
Outros Autores: Carvalho, Geraldo Alberto Pinheiro de, Franco, Amanda Gonçalves, Napimoga, Juliana Trindade Clemente, Napimoga, Marcelo Henrique, Bueno, Carlos Eduardo da Silveira, Amaral, Flávia Lucisano Botelho do
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Research, Society and Development
Texto Completo: https://rsdjournal.org/index.php/rsd/article/view/26183
Resumo: This study aims to assess the biomechanical behavior of the alveolar bone surrounding the implants over protocol with metal, Polyether ether ketone (PEEK) and Zantex bars, in normal and osteoporotic conditions.  For the simulation, geometric models of the mandibular arch were designed containing 5 implants and two variables. The first variable is the bone condition - normal and osteoporotic-, and the second is the material used in the protocol bars – metal, PEEK and Zantex. Simulation was performed using the Finite Elements Method. Results showed that the largest load peaks were concentrated in the medullary bone, both in the normal and osteoporotic conditions. The osteoporotic bone was subjected to more loads than the normal bone in all simulated structures. PEEK and Zantex bars are generally effective load dissipators, showing better performance than Ni-Cr in both types of bone. It is important to assess the bone condition and its relationship with the material used in protocol-type prostheses infrastructure.  
id UNIFEI_fc5646167f57eceda85122494f5cc2f2
oai_identifier_str oai:ojs.pkp.sfu.ca:article/26183
network_acronym_str UNIFEI
network_name_str Research, Society and Development
repository_id_str
spelling The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element MethodBiomecánica ósea, en condiciones normales y osteoporóticas, implantes circundantes bajo protocolos, y barras de metal, Zantex y PEEK: un análisis por el método de los elementos finitosBiomecânica óssea, em condição normal e osteoporótica, circundante a implantes sob protocolos, e das barras em metal, Zantex e PEEK: uma análise pelo Método de Elementos FinitosOsteoporosisDental prothesisFinite element analysis.OsteoporosisProtesis dentalAnalyse des éléments finis.OsteoporosePrótese dentáriaAnálise de elementos finitos.This study aims to assess the biomechanical behavior of the alveolar bone surrounding the implants over protocol with metal, Polyether ether ketone (PEEK) and Zantex bars, in normal and osteoporotic conditions.  For the simulation, geometric models of the mandibular arch were designed containing 5 implants and two variables. The first variable is the bone condition - normal and osteoporotic-, and the second is the material used in the protocol bars – metal, PEEK and Zantex. Simulation was performed using the Finite Elements Method. Results showed that the largest load peaks were concentrated in the medullary bone, both in the normal and osteoporotic conditions. The osteoporotic bone was subjected to more loads than the normal bone in all simulated structures. PEEK and Zantex bars are generally effective load dissipators, showing better performance than Ni-Cr in both types of bone. It is important to assess the bone condition and its relationship with the material used in protocol-type prostheses infrastructure.  El objetivo de este trabajo fue evaluar el comportamiento biomecánico del hueso alveolar, en condiciones normales y osteoporóticas, rodeando implantes bajo protocolo, con barras metálicas, Poliéter-éter-cetona (PEEK) y Zantex. Para la simulación se construyeron modelos geométricos del arco mandibular que contenían 5 implantes con dos variables. El primero fue la presencia de hueso normal y osteoporótico, y el segundo fue el material utilizado para fabricar las barras de protocolo, metal, PEEK y Zantex. La simulación se realizó por el Método de Elementos Finitos. Los resultados mostraron que los picos de carga más altos se concentraron en el hueso medular, tanto normal como osteoporótico. El hueso osteoporótico recibió más cargas que el hueso normal para todas las estructuras simuladas. Las barras de PEEK y Zantex demostraron ser elementos disipadores de estrés efectivos en general, con una disipación de fuerza mayor que el Ni-Cr en ambos tipos de huesos. Se concluye la importancia de evaluar el estado óseo y su relación entre el material utilizado en la infraestructura protésica tipo protocolo.O objetivo deste trabalho foi avaliar o comportamento biomecânico do osso alveolar, nas condições normal e osteoporótica, circundante a implantes sob protocolo, com barras em metal, Poliéter-éter-cetona (PEEK) e Zantex. Para a simulação foram construídos modelos geométricos de arco mandibular contendo 5 implantes com duas variáveis. A primeira foi a presença de osso normal e osteoporótico, e a segunda o material na confecção das barras de protocolo, metal, PEEK e Zantex. A simulação foi realizada pelo Método de Elementos Finitos. Os resultados mostraram que os maiores picos de carga foram concentrados no osso medular, tanto normal quanto osteoporótico. O osso osteoporótico recebeu mais cargas que o osso normal todas as estruturas simuladas. As barras em PEEK e Zantex se mostraram em geral elementos dissipadores de tensões efetivos, com uma dissipação de forças maior que Ni-Cr em ambos os tipos de ossos. Conclui-se a importância da avaliação condição óssea e sua relação entre o material utilizado em infraestrutura de próteses tipo protocolo.  Research, Society and Development2022-02-06info:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionapplication/pdfhttps://rsdjournal.org/index.php/rsd/article/view/2618310.33448/rsd-v11i2.26183Research, Society and Development; Vol. 11 No. 2; e59111226183Research, Society and Development; Vol. 11 Núm. 2; e59111226183Research, Society and Development; v. 11 n. 2; e591112261832525-3409reponame:Research, Society and Developmentinstname:Universidade Federal de Itajubá (UNIFEI)instacron:UNIFEIenghttps://rsdjournal.org/index.php/rsd/article/view/26183/22890Copyright (c) 2022 Aline Batista Gonçalves Franco; Geraldo Alberto Pinheiro de Carvalho; Amanda Gonçalves Franco; Juliana Trindade Clemente Napimoga; Marcelo Henrique Napimoga; Carlos Eduardo da Silveira Bueno; Flávia Lucisano Botelho do Amaralhttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccess Franco, Aline Batista GonçalvesCarvalho, Geraldo Alberto Pinheiro de Franco, Amanda Gonçalves Napimoga, Juliana Trindade Clemente Napimoga, Marcelo HenriqueBueno, Carlos Eduardo da Silveira Amaral, Flávia Lucisano Botelho do2022-02-07T01:42:50Zoai:ojs.pkp.sfu.ca:article/26183Revistahttps://rsdjournal.org/index.php/rsd/indexPUBhttps://rsdjournal.org/index.php/rsd/oairsd.articles@gmail.com2525-34092525-3409opendoar:2024-01-17T09:44:17.243736Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)false
dc.title.none.fl_str_mv The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method
Biomecánica ósea, en condiciones normales y osteoporóticas, implantes circundantes bajo protocolos, y barras de metal, Zantex y PEEK: un análisis por el método de los elementos finitos
Biomecânica óssea, em condição normal e osteoporótica, circundante a implantes sob protocolos, e das barras em metal, Zantex e PEEK: uma análise pelo Método de Elementos Finitos
title The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method
spellingShingle The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method
Franco, Aline Batista Gonçalves
Osteoporosis
Dental prothesis
Finite element analysis.
Osteoporosis
Protesis dental
Analyse des éléments finis.
Osteoporose
Prótese dentária
Análise de elementos finitos.
title_short The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method
title_full The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method
title_fullStr The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method
title_full_unstemmed The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method
title_sort The biomechanics of the bone and of metal, Zantex and PEEK bars in normal and osteoporotic condition, surrounding implants over protocols: an analysis by the Finite Element Method
author Franco, Aline Batista Gonçalves
author_facet Franco, Aline Batista Gonçalves
Carvalho, Geraldo Alberto Pinheiro de
Franco, Amanda Gonçalves
Napimoga, Juliana Trindade Clemente
Napimoga, Marcelo Henrique
Bueno, Carlos Eduardo da Silveira
Amaral, Flávia Lucisano Botelho do
author_role author
author2 Carvalho, Geraldo Alberto Pinheiro de
Franco, Amanda Gonçalves
Napimoga, Juliana Trindade Clemente
Napimoga, Marcelo Henrique
Bueno, Carlos Eduardo da Silveira
Amaral, Flávia Lucisano Botelho do
author2_role author
author
author
author
author
author
dc.contributor.author.fl_str_mv Franco, Aline Batista Gonçalves
Carvalho, Geraldo Alberto Pinheiro de
Franco, Amanda Gonçalves
Napimoga, Juliana Trindade Clemente
Napimoga, Marcelo Henrique
Bueno, Carlos Eduardo da Silveira
Amaral, Flávia Lucisano Botelho do
dc.subject.por.fl_str_mv Osteoporosis
Dental prothesis
Finite element analysis.
Osteoporosis
Protesis dental
Analyse des éléments finis.
Osteoporose
Prótese dentária
Análise de elementos finitos.
topic Osteoporosis
Dental prothesis
Finite element analysis.
Osteoporosis
Protesis dental
Analyse des éléments finis.
Osteoporose
Prótese dentária
Análise de elementos finitos.
description This study aims to assess the biomechanical behavior of the alveolar bone surrounding the implants over protocol with metal, Polyether ether ketone (PEEK) and Zantex bars, in normal and osteoporotic conditions.  For the simulation, geometric models of the mandibular arch were designed containing 5 implants and two variables. The first variable is the bone condition - normal and osteoporotic-, and the second is the material used in the protocol bars – metal, PEEK and Zantex. Simulation was performed using the Finite Elements Method. Results showed that the largest load peaks were concentrated in the medullary bone, both in the normal and osteoporotic conditions. The osteoporotic bone was subjected to more loads than the normal bone in all simulated structures. PEEK and Zantex bars are generally effective load dissipators, showing better performance than Ni-Cr in both types of bone. It is important to assess the bone condition and its relationship with the material used in protocol-type prostheses infrastructure.  
publishDate 2022
dc.date.none.fl_str_mv 2022-02-06
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/26183
10.33448/rsd-v11i2.26183
url https://rsdjournal.org/index.php/rsd/article/view/26183
identifier_str_mv 10.33448/rsd-v11i2.26183
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv https://rsdjournal.org/index.php/rsd/article/view/26183/22890
dc.rights.driver.fl_str_mv https://creativecommons.org/licenses/by/4.0
info:eu-repo/semantics/openAccess
rights_invalid_str_mv https://creativecommons.org/licenses/by/4.0
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Research, Society and Development
publisher.none.fl_str_mv Research, Society and Development
dc.source.none.fl_str_mv Research, Society and Development; Vol. 11 No. 2; e59111226183
Research, Society and Development; Vol. 11 Núm. 2; e59111226183
Research, Society and Development; v. 11 n. 2; e59111226183
2525-3409
reponame:Research, Society and Development
instname:Universidade Federal de Itajubá (UNIFEI)
instacron:UNIFEI
instname_str Universidade Federal de Itajubá (UNIFEI)
instacron_str UNIFEI
institution UNIFEI
reponame_str Research, Society and Development
collection Research, Society and Development
repository.name.fl_str_mv Research, Society and Development - Universidade Federal de Itajubá (UNIFEI)
repository.mail.fl_str_mv rsd.articles@gmail.com
_version_ 1797052704585940992