Effect of phosphoric acid concentration and anodizing time on the properties of anodic films on titanium
Autor(a) principal: | |
---|---|
Data de Publicação: | 2015 |
Outros Autores: | , , , |
Tipo de documento: | Artigo |
Idioma: | eng |
Título da fonte: | Repositório Institucional da UNESP |
Texto Completo: | http://hdl.handle.net/11449/227999 |
Resumo: | In this study, it was investigated the influence of electrolyte concentration and anodizing time on the electrochemical behaviour and morphology of anodic films formed on commercially pure Ti. Electrochemical methods and surface analyses were used to characterize the films. It was found that the electrolyte concentration and anodizing time affect the growth and protective characteristics of films in a physiologic medium. It was possible to observe their non-uniformity on Ti substrates under the tested conditions. In potentiodynamic profiles, it was observed that passivation current values are affected by an anodizing time increase. Variations in impedance spectra were associated with an increase of defects within the film. |
id |
UNSP_13cb9f1cb313b21d3392e7e9760d95e0 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/227999 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Effect of phosphoric acid concentration and anodizing time on the properties of anodic films on titaniumAnodic filmsAnodizingBiomedical implantsChloride mediumTitaniumIn this study, it was investigated the influence of electrolyte concentration and anodizing time on the electrochemical behaviour and morphology of anodic films formed on commercially pure Ti. Electrochemical methods and surface analyses were used to characterize the films. It was found that the electrolyte concentration and anodizing time affect the growth and protective characteristics of films in a physiologic medium. It was possible to observe their non-uniformity on Ti substrates under the tested conditions. In potentiodynamic profiles, it was observed that passivation current values are affected by an anodizing time increase. Variations in impedance spectra were associated with an increase of defects within the film.Physics and Chemistry Department, São Paulo State University, Guaratinguetá Campus, Dr. Ariberto Pereira da Cunha Ave. 333Physics and Chemistry Department, São Paulo State University, Guaratinguetá Campus, Dr. Ariberto Pereira da Cunha Ave. 333Universidade Estadual Paulista (UNESP)Torres, Dimas L. [UNESP]Pereira, Marinalda C. [UNESP]Silva, José W. J. [UNESP]Codaro, Eduardo N. [UNESP]Acciari, Heloisa A. [UNESP]2022-04-29T07:26:06Z2022-04-29T07:26:06Z2015-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article841-848Journal of Engineering Science and Technology, v. 10, n. 7, p. 841-848, 2015.1823-4690http://hdl.handle.net/11449/2279992-s2.0-84933515333Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengJournal of Engineering Science and Technologyinfo:eu-repo/semantics/openAccess2022-04-29T07:26:06Zoai:repositorio.unesp.br:11449/227999Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462022-04-29T07:26:06Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Effect of phosphoric acid concentration and anodizing time on the properties of anodic films on titanium |
title |
Effect of phosphoric acid concentration and anodizing time on the properties of anodic films on titanium |
spellingShingle |
Effect of phosphoric acid concentration and anodizing time on the properties of anodic films on titanium Torres, Dimas L. [UNESP] Anodic films Anodizing Biomedical implants Chloride medium Titanium |
title_short |
Effect of phosphoric acid concentration and anodizing time on the properties of anodic films on titanium |
title_full |
Effect of phosphoric acid concentration and anodizing time on the properties of anodic films on titanium |
title_fullStr |
Effect of phosphoric acid concentration and anodizing time on the properties of anodic films on titanium |
title_full_unstemmed |
Effect of phosphoric acid concentration and anodizing time on the properties of anodic films on titanium |
title_sort |
Effect of phosphoric acid concentration and anodizing time on the properties of anodic films on titanium |
author |
Torres, Dimas L. [UNESP] |
author_facet |
Torres, Dimas L. [UNESP] Pereira, Marinalda C. [UNESP] Silva, José W. J. [UNESP] Codaro, Eduardo N. [UNESP] Acciari, Heloisa A. [UNESP] |
author_role |
author |
author2 |
Pereira, Marinalda C. [UNESP] Silva, José W. J. [UNESP] Codaro, Eduardo N. [UNESP] Acciari, Heloisa A. [UNESP] |
author2_role |
author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (UNESP) |
dc.contributor.author.fl_str_mv |
Torres, Dimas L. [UNESP] Pereira, Marinalda C. [UNESP] Silva, José W. J. [UNESP] Codaro, Eduardo N. [UNESP] Acciari, Heloisa A. [UNESP] |
dc.subject.por.fl_str_mv |
Anodic films Anodizing Biomedical implants Chloride medium Titanium |
topic |
Anodic films Anodizing Biomedical implants Chloride medium Titanium |
description |
In this study, it was investigated the influence of electrolyte concentration and anodizing time on the electrochemical behaviour and morphology of anodic films formed on commercially pure Ti. Electrochemical methods and surface analyses were used to characterize the films. It was found that the electrolyte concentration and anodizing time affect the growth and protective characteristics of films in a physiologic medium. It was possible to observe their non-uniformity on Ti substrates under the tested conditions. In potentiodynamic profiles, it was observed that passivation current values are affected by an anodizing time increase. Variations in impedance spectra were associated with an increase of defects within the film. |
publishDate |
2015 |
dc.date.none.fl_str_mv |
2015-01-01 2022-04-29T07:26:06Z 2022-04-29T07:26:06Z |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
Journal of Engineering Science and Technology, v. 10, n. 7, p. 841-848, 2015. 1823-4690 http://hdl.handle.net/11449/227999 2-s2.0-84933515333 |
identifier_str_mv |
Journal of Engineering Science and Technology, v. 10, n. 7, p. 841-848, 2015. 1823-4690 2-s2.0-84933515333 |
url |
http://hdl.handle.net/11449/227999 |
dc.language.iso.fl_str_mv |
eng |
language |
eng |
dc.relation.none.fl_str_mv |
Journal of Engineering Science and Technology |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
841-848 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1799964522584211456 |