Determination of Hg in water by CVAAS using 2-aminothiazole modified silica

Detalhes bibliográficos
Autor(a) principal: Silva, F. A. [UNESP]
Data de Publicação: 2005
Outros Autores: De Alcântara, I. L. [UNESP], Roldan, P. S. [UNESP], Padilha, C. C.F. [UNESP], De Araújo, A. B. [UNESP], Valente, J. P.S. [UNESP], Florentino, A. O. [UNESP], Padilha, P. M. [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1007/s00572-004-0293-6
http://hdl.handle.net/11449/224696
Resumo: This paper discusses a rapid and sensitive method developed to determine trace levels of mercury in natural water samples by cold vapor atomic absorption spectrometry using a preconcentration system composed by mini-column packed with 100 mg of 2-aminothiazol modified silica gel (SiAT) coupled on-line with the spectrometer's cold vapor generator system. The optimum preconcentration conditions are also described here. The preconcentrated Hg(II) ions were eluted directly from the column to the spectrometer's cold vapor generator system using 100 μL of 2 mol L-1 hydrochloric acid and the retention efficiency achieved exceeded 95%. The enrichment factors determined were 29, 38 and 46 using 3, 4 and 5 mL of preconcentrated aqueous solutions containing 400 ng L-1 of Hg. The detection limit calculated was 5 ng L-1. The preconcentration procedure was applied to determine trace level mercury in spiked river water samples.
id UNSP_2d14ab02be05c0416e0c95ea66988bf5
oai_identifier_str oai:repositorio.unesp.br:11449/224696
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Determination of Hg in water by CVAAS using 2-aminothiazole modified silicaCVAASFlow-injection analysisMercuryModified silicaPreconcentrationThis paper discusses a rapid and sensitive method developed to determine trace levels of mercury in natural water samples by cold vapor atomic absorption spectrometry using a preconcentration system composed by mini-column packed with 100 mg of 2-aminothiazol modified silica gel (SiAT) coupled on-line with the spectrometer's cold vapor generator system. The optimum preconcentration conditions are also described here. The preconcentrated Hg(II) ions were eluted directly from the column to the spectrometer's cold vapor generator system using 100 μL of 2 mol L-1 hydrochloric acid and the retention efficiency achieved exceeded 95%. The enrichment factors determined were 29, 38 and 46 using 3, 4 and 5 mL of preconcentrated aqueous solutions containing 400 ng L-1 of Hg. The detection limit calculated was 5 ng L-1. The preconcentration procedure was applied to determine trace level mercury in spiked river water samples.Instituto de Biociências Departamento de Química e Bioquímica/UNESP, Caixa Postal 510, 18618-000, Botucatu, SPInstituto de Química Departamento de Química Analítica/UNESP, Caixa Postal 355, 14800-900, Araraquara, SPInstituto de Biociências Departamento de Física e Biofísica/UNESP, Caixa Postal 510, 18618-000, Botucatu, SPInstituto de Biociências Departamento de Química e Bioquímica/UNESP, Caixa Postal 510, 18618-000, Botucatu, SPInstituto de Química Departamento de Química Analítica/UNESP, Caixa Postal 355, 14800-900, Araraquara, SPInstituto de Biociências Departamento de Física e Biofísica/UNESP, Caixa Postal 510, 18618-000, Botucatu, SPUniversidade Estadual Paulista (UNESP)Silva, F. A. [UNESP]De Alcântara, I. L. [UNESP]Roldan, P. S. [UNESP]Padilha, C. C.F. [UNESP]De Araújo, A. B. [UNESP]Valente, J. P.S. [UNESP]Florentino, A. O. [UNESP]Padilha, P. M. [UNESP]2022-04-28T20:06:55Z2022-04-28T20:06:55Z2005-07-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article47-55http://dx.doi.org/10.1007/s00572-004-0293-6Ecletica Quimica, v. 30, n. 3, p. 47-55, 2005.0100-4670http://hdl.handle.net/11449/22469610.1007/s00572-004-0293-62-s2.0-31344464410Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengEcletica Quimicainfo:eu-repo/semantics/openAccess2022-04-28T20:06:55Zoai:repositorio.unesp.br:11449/224696Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462022-04-28T20:06:55Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Determination of Hg in water by CVAAS using 2-aminothiazole modified silica
title Determination of Hg in water by CVAAS using 2-aminothiazole modified silica
spellingShingle Determination of Hg in water by CVAAS using 2-aminothiazole modified silica
Silva, F. A. [UNESP]
CVAAS
Flow-injection analysis
Mercury
Modified silica
Preconcentration
title_short Determination of Hg in water by CVAAS using 2-aminothiazole modified silica
title_full Determination of Hg in water by CVAAS using 2-aminothiazole modified silica
title_fullStr Determination of Hg in water by CVAAS using 2-aminothiazole modified silica
title_full_unstemmed Determination of Hg in water by CVAAS using 2-aminothiazole modified silica
title_sort Determination of Hg in water by CVAAS using 2-aminothiazole modified silica
author Silva, F. A. [UNESP]
author_facet Silva, F. A. [UNESP]
De Alcântara, I. L. [UNESP]
Roldan, P. S. [UNESP]
Padilha, C. C.F. [UNESP]
De Araújo, A. B. [UNESP]
Valente, J. P.S. [UNESP]
Florentino, A. O. [UNESP]
Padilha, P. M. [UNESP]
author_role author
author2 De Alcântara, I. L. [UNESP]
Roldan, P. S. [UNESP]
Padilha, C. C.F. [UNESP]
De Araújo, A. B. [UNESP]
Valente, J. P.S. [UNESP]
Florentino, A. O. [UNESP]
Padilha, P. M. [UNESP]
author2_role author
author
author
author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (UNESP)
dc.contributor.author.fl_str_mv Silva, F. A. [UNESP]
De Alcântara, I. L. [UNESP]
Roldan, P. S. [UNESP]
Padilha, C. C.F. [UNESP]
De Araújo, A. B. [UNESP]
Valente, J. P.S. [UNESP]
Florentino, A. O. [UNESP]
Padilha, P. M. [UNESP]
dc.subject.por.fl_str_mv CVAAS
Flow-injection analysis
Mercury
Modified silica
Preconcentration
topic CVAAS
Flow-injection analysis
Mercury
Modified silica
Preconcentration
description This paper discusses a rapid and sensitive method developed to determine trace levels of mercury in natural water samples by cold vapor atomic absorption spectrometry using a preconcentration system composed by mini-column packed with 100 mg of 2-aminothiazol modified silica gel (SiAT) coupled on-line with the spectrometer's cold vapor generator system. The optimum preconcentration conditions are also described here. The preconcentrated Hg(II) ions were eluted directly from the column to the spectrometer's cold vapor generator system using 100 μL of 2 mol L-1 hydrochloric acid and the retention efficiency achieved exceeded 95%. The enrichment factors determined were 29, 38 and 46 using 3, 4 and 5 mL of preconcentrated aqueous solutions containing 400 ng L-1 of Hg. The detection limit calculated was 5 ng L-1. The preconcentration procedure was applied to determine trace level mercury in spiked river water samples.
publishDate 2005
dc.date.none.fl_str_mv 2005-07-01
2022-04-28T20:06:55Z
2022-04-28T20:06:55Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1007/s00572-004-0293-6
Ecletica Quimica, v. 30, n. 3, p. 47-55, 2005.
0100-4670
http://hdl.handle.net/11449/224696
10.1007/s00572-004-0293-6
2-s2.0-31344464410
url http://dx.doi.org/10.1007/s00572-004-0293-6
http://hdl.handle.net/11449/224696
identifier_str_mv Ecletica Quimica, v. 30, n. 3, p. 47-55, 2005.
0100-4670
10.1007/s00572-004-0293-6
2-s2.0-31344464410
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Ecletica Quimica
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 47-55
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799965497035325440