Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching

Detalhes bibliográficos
Autor(a) principal: Carvalho, Bruno Andrade Cantharino De
Data de Publicação: 2015
Outros Autores: Vedovatto, Eduardo, Carvalho, Paulo Sérgio Perri de, Mazaro, José Vitor Quinelli, Falcón-antenucci, Rosse Mary [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300284&lng=en&nrm=iso&tlng=en
http://hdl.handle.net/11449/127324
Resumo: This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
id UNSP_3cb24ebac28ca18172dca4e0c07884fd
oai_identifier_str oai:repositorio.unesp.br:11449/127324
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switchingDental implantsPlatform switchingReverse torqueMechanical cyclingThis in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.Este estudo in vitro avaliou o efeito da ciclagem mecânica no torque dos parafusos de retenção em implantes de hexágono externo com plataforma switching (PS), plataforma regular (RP) e plataforma larga (WP). Foram utilizados 30 corpos de prova divididos em 3 grupos equitativamente: PS, RP e WP. Cada corpo de prova foi preparado com implantes: 3,75x10 mm para o grupo RP e 5,0x10 mm para os grupos PS e WP, e seu respectivo abutment com o torque de 32 Ncm. Todos os grupos foram submetidos a 106 ciclos com 100 N de força (o que corresponde a aproximadamente 40 meses de mastigação). Os resultados foram obtidos com o torque reverso de cada espécime e os dados foram avaliados com ANOVA comparado com o teste de Tukey (p<0,05). O grupo PS apresentou diferença estatisticamente significante no torque de remoção do parafuso (30,06±5,42) comparado com os grupos RP (23,75±2,76) e WP (21,32±3,53) (p<0,05); os grupos RP e WP não apresentaram diferença estatisticamente significante entre si. Concluiu-se que o grupo PS apresentou maior valor de torque reverso sugerindo menor susceptibilidade de afrouxamento do parafuso de fixação do abutment.Faculdade de Odontologia São Leopoldo Mandic Department of Oral ImplantologyUniversidade Estadual Paulista Araçatuba Dental School Department of Dental Materials and ProsthodonticsUniversidade Estadual Paulista Araçatuba Dental School Department of Dental Materials and ProsthodonticsFundação Odontológica de Ribeirão PretoSão Leopoldo Mandic (SLMANDIC)Universidade Estadual Paulista (Unesp)Carvalho, Bruno Andrade Cantharino DeVedovatto, EduardoCarvalho, Paulo Sérgio Perri deMazaro, José Vitor QuinelliFalcón-antenucci, Rosse Mary [UNESP]2015-08-26T19:19:11Z2015-08-26T19:19:11Z2015-06-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article284-287application/pdfhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300284&lng=en&nrm=iso&tlng=enBrazilian Dental Journal, v. 26, n. 3, p. 284-287, 2015.0103-6440http://hdl.handle.net/11449/12732410.1590/0103-6440201300296S0103-64402015000300284S0103-64402015000300284.pdf1239305418355498SciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Dental Journal0,476info:eu-repo/semantics/openAccess2023-10-26T06:06:19Zoai:repositorio.unesp.br:11449/127324Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-10-26T06:06:19Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching
title Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching
spellingShingle Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching
Carvalho, Bruno Andrade Cantharino De
Dental implants
Platform switching
Reverse torque
Mechanical cycling
title_short Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching
title_full Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching
title_fullStr Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching
title_full_unstemmed Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching
title_sort Effect of mechanical cycling on screw torque in external hexagon implants with and without platform switching
author Carvalho, Bruno Andrade Cantharino De
author_facet Carvalho, Bruno Andrade Cantharino De
Vedovatto, Eduardo
Carvalho, Paulo Sérgio Perri de
Mazaro, José Vitor Quinelli
Falcón-antenucci, Rosse Mary [UNESP]
author_role author
author2 Vedovatto, Eduardo
Carvalho, Paulo Sérgio Perri de
Mazaro, José Vitor Quinelli
Falcón-antenucci, Rosse Mary [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv São Leopoldo Mandic (SLMANDIC)
Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Carvalho, Bruno Andrade Cantharino De
Vedovatto, Eduardo
Carvalho, Paulo Sérgio Perri de
Mazaro, José Vitor Quinelli
Falcón-antenucci, Rosse Mary [UNESP]
dc.subject.por.fl_str_mv Dental implants
Platform switching
Reverse torque
Mechanical cycling
topic Dental implants
Platform switching
Reverse torque
Mechanical cycling
description This in vitro study evaluated the effect of mechanical cycling on the torque of retaining screw in external hexagon implants with platform switching (PS), regular platform (RP) and wide platform (WP). A total of 30 specimens were equally divided into 3 groups: PS, PR and WP. Each specimen was prepared with implants: 3.75 x 10 mm for RP group and 5.0x10 mm for PS and WP groups and its respective abutment with 32 Ncm torque. All groups were subjected to 106 cycles with 100 N (corresponding to about 40 months of chewing). The results were obtained with the reverse torque of each specimen and data were evaluated using ANOVA and Tukey test (p<0.05). The PS group showed statistically significant difference in screw removal torque (30.06±5.42) compared with RP (23.75±2.76) and WP (21.32±3.53) (p<0.05) groups; the RP and WP groups showed no statistically significant difference between them. It was concluded that the PS group showed higher reverse torque value, suggesting lower susceptibility of the abutment screw loosening.
publishDate 2015
dc.date.none.fl_str_mv 2015-08-26T19:19:11Z
2015-08-26T19:19:11Z
2015-06-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300284&lng=en&nrm=iso&tlng=en
Brazilian Dental Journal, v. 26, n. 3, p. 284-287, 2015.
0103-6440
http://hdl.handle.net/11449/127324
10.1590/0103-6440201300296
S0103-64402015000300284
S0103-64402015000300284.pdf
1239305418355498
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300284&lng=en&nrm=iso&tlng=en
http://hdl.handle.net/11449/127324
identifier_str_mv Brazilian Dental Journal, v. 26, n. 3, p. 284-287, 2015.
0103-6440
10.1590/0103-6440201300296
S0103-64402015000300284
S0103-64402015000300284.pdf
1239305418355498
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Dental Journal
0,476
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 284-287
application/pdf
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799964702993809408