Simultaneous determination of Fe and Zn in dried blood spot by HR-CS GF AAS using solid sampling

Detalhes bibliográficos
Autor(a) principal: Vieira, Alan L. [UNESP]
Data de Publicação: 2021
Outros Autores: Ferreira, Edilene C. [UNESP], Oliveira, Silvana R., Barbosa, Fernando, Neto, José A. Gomes [UNESP]
Tipo de documento: Artigo
Idioma: eng
Título da fonte: Repositório Institucional da UNESP
Texto Completo: http://dx.doi.org/10.1016/j.microc.2020.105637
http://hdl.handle.net/11449/205434
Resumo: Dried Blood Spot (DBS) was evaluated as a solid sampling (SS) strategy for the simultaneous determination of Fe and Zn in blood samples by Solid Sampling High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (SS HR-CS GF AAS). The alternative lines of Fe and Zn at 307.572 and 307.589 nm, respectively, were evaluated. A good correlation between the area of DBS (in mm2) and volume of blood (in µL) was observed up to 200 µL of blood. A 3.4 mm diameter paper disk, equivalent 3.86 ± 0.13 µL, was punched from the DBS and employed for blood analysis. Random sampling through the area of the paper circle produced by 50 μL blood samples showed no chromatographic effects. The upside of the solid sampling 'boat type' graphite platform was coated with a W-based film. This coating allowed around 350 firings. The use of 3 µL of 15% v/v H2O2 solution as chemical modifier improved both the thermal stability and peak profile of Zn for aqueous medium (standard solution deposited onto Whatman paper), possibly because of the weakening of Zn-paper interactions or even by the formation of thermally more stable Zn oxides. Solid standards used for calibration in the 0.1–3.0 µg Fe and 5.0–50.0 ng Zn ranges were prepared with Whatman 903® paper discs impregnated with standard solutions of the analytes. Results for Fe and Zn determined by the proposed SS HR-CS GF AAS method were in agreement at a 95% confidence level (paired t-test) with those obtained by the comparative method (except for one sample) based on microwave-assisted acid digestion of blood and High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS F AAS). The limits of quantification were 10.2 mg/L (0.04 µg) for Fe and 1.2 mg/L (4.6 ng) for Zn. The relative standard deviation was < 10% (n = 12) for a sample containing 516 mg/L Fe and 8.7 mg/L Zn, and the sample throughput was equivalent to ca. 90 s per measurement.
id UNSP_6c7c40534eac9924116d31b22cf36d76
oai_identifier_str oai:repositorio.unesp.br:11449/205434
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Simultaneous determination of Fe and Zn in dried blood spot by HR-CS GF AAS using solid samplingDried blood spotFeHR-CS GF AASSolid samplingZnDried Blood Spot (DBS) was evaluated as a solid sampling (SS) strategy for the simultaneous determination of Fe and Zn in blood samples by Solid Sampling High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (SS HR-CS GF AAS). The alternative lines of Fe and Zn at 307.572 and 307.589 nm, respectively, were evaluated. A good correlation between the area of DBS (in mm2) and volume of blood (in µL) was observed up to 200 µL of blood. A 3.4 mm diameter paper disk, equivalent 3.86 ± 0.13 µL, was punched from the DBS and employed for blood analysis. Random sampling through the area of the paper circle produced by 50 μL blood samples showed no chromatographic effects. The upside of the solid sampling 'boat type' graphite platform was coated with a W-based film. This coating allowed around 350 firings. The use of 3 µL of 15% v/v H2O2 solution as chemical modifier improved both the thermal stability and peak profile of Zn for aqueous medium (standard solution deposited onto Whatman paper), possibly because of the weakening of Zn-paper interactions or even by the formation of thermally more stable Zn oxides. Solid standards used for calibration in the 0.1–3.0 µg Fe and 5.0–50.0 ng Zn ranges were prepared with Whatman 903® paper discs impregnated with standard solutions of the analytes. Results for Fe and Zn determined by the proposed SS HR-CS GF AAS method were in agreement at a 95% confidence level (paired t-test) with those obtained by the comparative method (except for one sample) based on microwave-assisted acid digestion of blood and High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS F AAS). The limits of quantification were 10.2 mg/L (0.04 µg) for Fe and 1.2 mg/L (4.6 ng) for Zn. The relative standard deviation was < 10% (n = 12) for a sample containing 516 mg/L Fe and 8.7 mg/L Zn, and the sample throughput was equivalent to ca. 90 s per measurement.Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)São Paulo State University – UNESPFaculdade de Ciências Farmacêuticas de Ribeirão Preto Universidade de São PauloSão Paulo State University – UNESPFAPESP: 2018/24069-3FAPESP: 2019/07537-6Universidade Estadual Paulista (Unesp)Universidade de São Paulo (USP)Vieira, Alan L. [UNESP]Ferreira, Edilene C. [UNESP]Oliveira, Silvana R.Barbosa, FernandoNeto, José A. Gomes [UNESP]2021-06-25T10:15:12Z2021-06-25T10:15:12Z2021-01-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlehttp://dx.doi.org/10.1016/j.microc.2020.105637Microchemical Journal, v. 160.0026-265Xhttp://hdl.handle.net/11449/20543410.1016/j.microc.2020.1056372-s2.0-85095454261Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengMicrochemical Journalinfo:eu-repo/semantics/openAccess2021-10-23T14:26:55Zoai:repositorio.unesp.br:11449/205434Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462021-10-23T14:26:55Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Simultaneous determination of Fe and Zn in dried blood spot by HR-CS GF AAS using solid sampling
title Simultaneous determination of Fe and Zn in dried blood spot by HR-CS GF AAS using solid sampling
spellingShingle Simultaneous determination of Fe and Zn in dried blood spot by HR-CS GF AAS using solid sampling
Vieira, Alan L. [UNESP]
Dried blood spot
Fe
HR-CS GF AAS
Solid sampling
Zn
title_short Simultaneous determination of Fe and Zn in dried blood spot by HR-CS GF AAS using solid sampling
title_full Simultaneous determination of Fe and Zn in dried blood spot by HR-CS GF AAS using solid sampling
title_fullStr Simultaneous determination of Fe and Zn in dried blood spot by HR-CS GF AAS using solid sampling
title_full_unstemmed Simultaneous determination of Fe and Zn in dried blood spot by HR-CS GF AAS using solid sampling
title_sort Simultaneous determination of Fe and Zn in dried blood spot by HR-CS GF AAS using solid sampling
author Vieira, Alan L. [UNESP]
author_facet Vieira, Alan L. [UNESP]
Ferreira, Edilene C. [UNESP]
Oliveira, Silvana R.
Barbosa, Fernando
Neto, José A. Gomes [UNESP]
author_role author
author2 Ferreira, Edilene C. [UNESP]
Oliveira, Silvana R.
Barbosa, Fernando
Neto, José A. Gomes [UNESP]
author2_role author
author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
Universidade de São Paulo (USP)
dc.contributor.author.fl_str_mv Vieira, Alan L. [UNESP]
Ferreira, Edilene C. [UNESP]
Oliveira, Silvana R.
Barbosa, Fernando
Neto, José A. Gomes [UNESP]
dc.subject.por.fl_str_mv Dried blood spot
Fe
HR-CS GF AAS
Solid sampling
Zn
topic Dried blood spot
Fe
HR-CS GF AAS
Solid sampling
Zn
description Dried Blood Spot (DBS) was evaluated as a solid sampling (SS) strategy for the simultaneous determination of Fe and Zn in blood samples by Solid Sampling High-Resolution Continuum Source Graphite Furnace Atomic Absorption Spectrometry (SS HR-CS GF AAS). The alternative lines of Fe and Zn at 307.572 and 307.589 nm, respectively, were evaluated. A good correlation between the area of DBS (in mm2) and volume of blood (in µL) was observed up to 200 µL of blood. A 3.4 mm diameter paper disk, equivalent 3.86 ± 0.13 µL, was punched from the DBS and employed for blood analysis. Random sampling through the area of the paper circle produced by 50 μL blood samples showed no chromatographic effects. The upside of the solid sampling 'boat type' graphite platform was coated with a W-based film. This coating allowed around 350 firings. The use of 3 µL of 15% v/v H2O2 solution as chemical modifier improved both the thermal stability and peak profile of Zn for aqueous medium (standard solution deposited onto Whatman paper), possibly because of the weakening of Zn-paper interactions or even by the formation of thermally more stable Zn oxides. Solid standards used for calibration in the 0.1–3.0 µg Fe and 5.0–50.0 ng Zn ranges were prepared with Whatman 903® paper discs impregnated with standard solutions of the analytes. Results for Fe and Zn determined by the proposed SS HR-CS GF AAS method were in agreement at a 95% confidence level (paired t-test) with those obtained by the comparative method (except for one sample) based on microwave-assisted acid digestion of blood and High-Resolution Continuum Source Flame Atomic Absorption Spectrometry (HR-CS F AAS). The limits of quantification were 10.2 mg/L (0.04 µg) for Fe and 1.2 mg/L (4.6 ng) for Zn. The relative standard deviation was < 10% (n = 12) for a sample containing 516 mg/L Fe and 8.7 mg/L Zn, and the sample throughput was equivalent to ca. 90 s per measurement.
publishDate 2021
dc.date.none.fl_str_mv 2021-06-25T10:15:12Z
2021-06-25T10:15:12Z
2021-01-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://dx.doi.org/10.1016/j.microc.2020.105637
Microchemical Journal, v. 160.
0026-265X
http://hdl.handle.net/11449/205434
10.1016/j.microc.2020.105637
2-s2.0-85095454261
url http://dx.doi.org/10.1016/j.microc.2020.105637
http://hdl.handle.net/11449/205434
identifier_str_mv Microchemical Journal, v. 160.
0026-265X
10.1016/j.microc.2020.105637
2-s2.0-85095454261
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Microchemical Journal
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.source.none.fl_str_mv Scopus
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1797789763977084928