Resumo: In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
id UNSP_7984ab702c0cc74e61a29852534a9b92
oai_identifier_str oai:repositorio.unesp.br:11449/127366
network_acronym_str UNSP
network_name_str Repositório Institucional da UNESP
repository_id_str 2946
spelling Load-application devices: a comparative strain gauge analysisDental implantsDental prosthesisImplant-supported dental prosthesisIn view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.Considerando os valores relativamente pequenos utilizados em odontologia para os ensaios de carregamento verticais axiais, foi desenvolvido um dispositivo de aplicação de carga (DAC) para substituir a máquina de ensaios universal (EMIC). O objetivo deste estudo foi desenvolver um DAC e compará-lo com a EMIC por meio da utilização de carregamentos axiais e não-axiais. Num bloco de poliuretano foi inserido um implante hexágono externo, o qual foi conectado a um pilar protético esteticone. Sobre o pilar protético foi parafusada uma coifa plástica e um pilar cônico foi modelado em resina acrílica, que foi moldada para a obtenção de dez enceramentos iguais que foram fundidos em níquel cromo. Quatro extensômetros foram diametralmente colados ao redor do implante. Cada corpo de prova foi submetido a cargas axiais central (C) e lateral (L) de 30 kgf, em ambos os dispositivos: G1) DAC/C; G2) DAC/L; G3) EMIC/C; G4) EMIC/L. Os dados (µε) foram analisados estatisticamente pelos testes de ANOVA para medidas repetidas e de Tukey (p<0,05). Não houve diferença estatisticamente significante entre os dispositivos DAC e EMIC, independente do tipo de carga. A aplicação de carga não-axial (NA) determinou um aumento significante de tensões ao redor do implante. Foi concluído que o DAC é uma opção confiável, a qual induz microtensão em implantes de forma semelhante à EMIC.Universidade Estadual Paulista São José dos Campos Dental School Department of Dental Materials and ProsthodonticsUniversidade Estadual Paulista São José dos Campos Dental School Department of Bioscience and Oral DiagnosisUniversidade Estadual Paulista São José dos Campos Dental School Department of Dental Materials and ProsthodonticsUniversidade Estadual Paulista São José dos Campos Dental School Department of Bioscience and Oral DiagnosisFundação Odontológica de Ribeirão PretoUniversidade Estadual Paulista (Unesp)Nishioka, Renato SussumuVasconcellos, Luis Gustavo Oliveira DeJóias, Renata PilliRode, Sigmar de Mello2015-08-26T19:19:21Z2015-08-26T19:19:21Z2015-06-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/article258-262application/pdfhttp://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300258&lng=en&nrm=iso&tlng=enBrazilian Dental Journal, v. 26, n. 3, p. 258-262, 2015.0103-6440http://hdl.handle.net/11449/12736610.1590/0103-6440201300321S0103-64402015000300258S0103-64402015000300258.pdf005666084228439734221189584299090000-0002-1458-601XSciELOreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengBrazilian Dental Journal0,476info:eu-repo/semantics/openAccess2023-12-28T06:14:02Zoai:repositorio.unesp.br:11449/127366Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462023-12-28T06:14:02Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false
dc.title.none.fl_str_mv Load-application devices: a comparative strain gauge analysis
title Load-application devices: a comparative strain gauge analysis
spellingShingle Load-application devices: a comparative strain gauge analysis
Nishioka, Renato Sussumu
Dental implants
Dental prosthesis
Implant-supported dental prosthesis
title_short Load-application devices: a comparative strain gauge analysis
title_full Load-application devices: a comparative strain gauge analysis
title_fullStr Load-application devices: a comparative strain gauge analysis
title_full_unstemmed Load-application devices: a comparative strain gauge analysis
title_sort Load-application devices: a comparative strain gauge analysis
author Nishioka, Renato Sussumu
author_facet Nishioka, Renato Sussumu
Vasconcellos, Luis Gustavo Oliveira De
Jóias, Renata Pilli
Rode, Sigmar de Mello
author_role author
author2 Vasconcellos, Luis Gustavo Oliveira De
Jóias, Renata Pilli
Rode, Sigmar de Mello
author2_role author
author
author
dc.contributor.none.fl_str_mv Universidade Estadual Paulista (Unesp)
dc.contributor.author.fl_str_mv Nishioka, Renato Sussumu
Vasconcellos, Luis Gustavo Oliveira De
Jóias, Renata Pilli
Rode, Sigmar de Mello
dc.subject.por.fl_str_mv Dental implants
Dental prosthesis
Implant-supported dental prosthesis
topic Dental implants
Dental prosthesis
Implant-supported dental prosthesis
description In view of the low loading values commonly employed in dentistry, a load-application device (LAD) was developed as option to the universal testing machine (UTM), using strain gauge analysis. The aim of this study was to develop a load-application device (LAD) and compare the LAD with the UTM apparatus under axial and non-axial loads. An external hexagonal implant was inserted into a polyurethane block and one EsthetiCone abutment was connected to the implant. A plastic prosthetic cylinder was screwed onto the abutment and a conical pattern crown was fabricated using acrylic resin. An impression was made and ten identical standard acrylic resin patterns were obtained from the crown impression, which were cast in nickel-chromium alloy (n=10). Four strain gauges were bonded diametrically around the implant. The specimens were subjected to central (C) and lateral (L) axial loads of 30 kgf, on both devices: G1: LAD/C; G2: LAD/L; G3: UTM/C; G4: UTM/L. The data (με) were statistically analyzed by repeated measures ANOVA and Tukey's test (p<0.05). No statistically significant difference was found between the UTM and LAD devices, regardless of the type of load. It was concluded that the LAD is a reliable alternative, which induces microstrains to implants similar to those obtained with the UTM.
publishDate 2015
dc.date.none.fl_str_mv 2015-08-26T19:19:21Z
2015-08-26T19:19:21Z
2015-06-01
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/article
format article
status_str publishedVersion
dc.identifier.uri.fl_str_mv http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300258&lng=en&nrm=iso&tlng=en
Brazilian Dental Journal, v. 26, n. 3, p. 258-262, 2015.
0103-6440
http://hdl.handle.net/11449/127366
10.1590/0103-6440201300321
S0103-64402015000300258
S0103-64402015000300258.pdf
0056660842284397
3422118958429909
0000-0002-1458-601X
url http://www.scielo.br/scielo.php?script=sci_arttext&pid=S0103-64402015000300258&lng=en&nrm=iso&tlng=en
http://hdl.handle.net/11449/127366
identifier_str_mv Brazilian Dental Journal, v. 26, n. 3, p. 258-262, 2015.
0103-6440
10.1590/0103-6440201300321
S0103-64402015000300258
S0103-64402015000300258.pdf
0056660842284397
3422118958429909
0000-0002-1458-601X
dc.language.iso.fl_str_mv eng
language eng
dc.relation.none.fl_str_mv Brazilian Dental Journal
0,476
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv 258-262
application/pdf
dc.publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
publisher.none.fl_str_mv Fundação Odontológica de Ribeirão Preto
dc.source.none.fl_str_mv SciELO
reponame:Repositório Institucional da UNESP
instname:Universidade Estadual Paulista (UNESP)
instacron:UNESP
instname_str Universidade Estadual Paulista (UNESP)
instacron_str UNESP
institution UNESP
reponame_str Repositório Institucional da UNESP
collection Repositório Institucional da UNESP
repository.name.fl_str_mv Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)
repository.mail.fl_str_mv
_version_ 1799965429998813184