Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry
Main Author: | |
---|---|
Publication Date: | 2021 |
Other Authors: | , , , , |
Format: | Article |
Language: | eng fra |
Source: | Repositório Institucional da UNESP |
Download full: | http://dx.doi.org/10.1016/j.scispo.2020.09.005 http://hdl.handle.net/11449/206840 |
Summary: | Objective: To evaluate reliability of performance and metabolic expenditure during a shoulder abduction endurance test with isokinetic dynamometer. Methods: A total of 28 healthy adults participated in 4 sessions (Orientation, Familiarization, Test and Retest). The muscle endurance test was performed using 50% of the individual maximal isometric voluntary contraction strength (21.9 ± 5.8 Nm). Participants performed repeated 0–90° shoulder abductions until exhaustion in the isokinetic dynamometer at a velocity of 60°/s. Values of time, repetition, rhythm and total work were analyzed. Results: For test and retest, respectively, time to fatigue (seconds) was 95.5 ± 37.6 and 91.1 ± 32.8 (P = 0.27), and repetitions were 31.4 ± 12.1 and 29.9 ± 10.6 (P = 0.23). Reliability was satisfactory [Time: ICC = 0.83 (95% CI = 0.66; 0.92); Repetition: ICC = 0.83 (95% CI = 0. 67; 0.92); Rhythm: ICC = 0.55 (95% CI = 0.24; 0.77); Total work: ICC = 0.85 (95% CI = 0.69; 0.93)]. Conclusion: The isokinetic test for shoulder muscle endurance at 50% of maximal muscle strength has good reliability. |
id |
UNSP_caa769af7626b305dc4d3e81485df926 |
---|---|
oai_identifier_str |
oai:repositorio.unesp.br:11449/206840 |
network_acronym_str |
UNSP |
network_name_str |
Repositório Institucional da UNESP |
repository_id_str |
2946 |
spelling |
Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometryÉvaluation de la fiabilité de la mesure d'endurance musculaire de l'abduction de l’épaule à l'aide d'un dynamomètre isocinétiqueFatigueMuscle strength dynamometerReproducibility of resultsResistance trainingObjective: To evaluate reliability of performance and metabolic expenditure during a shoulder abduction endurance test with isokinetic dynamometer. Methods: A total of 28 healthy adults participated in 4 sessions (Orientation, Familiarization, Test and Retest). The muscle endurance test was performed using 50% of the individual maximal isometric voluntary contraction strength (21.9 ± 5.8 Nm). Participants performed repeated 0–90° shoulder abductions until exhaustion in the isokinetic dynamometer at a velocity of 60°/s. Values of time, repetition, rhythm and total work were analyzed. Results: For test and retest, respectively, time to fatigue (seconds) was 95.5 ± 37.6 and 91.1 ± 32.8 (P = 0.27), and repetitions were 31.4 ± 12.1 and 29.9 ± 10.6 (P = 0.23). Reliability was satisfactory [Time: ICC = 0.83 (95% CI = 0.66; 0.92); Repetition: ICC = 0.83 (95% CI = 0. 67; 0.92); Rhythm: ICC = 0.55 (95% CI = 0.24; 0.77); Total work: ICC = 0.85 (95% CI = 0.69; 0.93)]. Conclusion: The isokinetic test for shoulder muscle endurance at 50% of maximal muscle strength has good reliability.Physiotherapy Department São Paulo State University (UNESP), 305, Roberto Simonsen, Presidente PrudenteNational Research Centre for the Working Environment, Lersø Parkalle 105Sport Sciences Department of Health Science and Technology Aalborg UniversityPhysiotherapy Department Universidade Estadual do Norte do Paraná (UENP) JacarezinhoFederal University of Mato Grosso (UFMT) Mato GrossoPhysiotherapy Department São Paulo State University (UNESP), 305, Roberto Simonsen, Presidente PrudenteUniversidade Estadual Paulista (Unesp)National Research Centre for the Working EnvironmentAalborg UniversityJacarezinhoMato GrossoMicheletti, J. K. [UNESP]Andersen, L. L.Machado, A. F.Lopes, J. S.S.Souto, L. R.Pastre, C. M. [UNESP]2021-06-25T10:44:43Z2021-06-25T10:44:43Z2021-06-01info:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/articlee111-e119http://dx.doi.org/10.1016/j.scispo.2020.09.005Science and Sports, v. 36, n. 3, p. e111-e119, 2021.1778-41310765-1597http://hdl.handle.net/11449/20684010.1016/j.scispo.2020.09.0052-s2.0-85096125707Scopusreponame:Repositório Institucional da UNESPinstname:Universidade Estadual Paulista (UNESP)instacron:UNESPengfraScience and Sportsinfo:eu-repo/semantics/openAccess2024-06-18T18:43:51Zoai:repositorio.unesp.br:11449/206840Repositório InstitucionalPUBhttp://repositorio.unesp.br/oai/requestopendoar:29462024-08-05T17:23:37.882380Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP)false |
dc.title.none.fl_str_mv |
Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry Évaluation de la fiabilité de la mesure d'endurance musculaire de l'abduction de l’épaule à l'aide d'un dynamomètre isocinétique |
title |
Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry |
spellingShingle |
Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry Micheletti, J. K. [UNESP] Fatigue Muscle strength dynamometer Reproducibility of results Resistance training |
title_short |
Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry |
title_full |
Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry |
title_fullStr |
Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry |
title_full_unstemmed |
Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry |
title_sort |
Reliability of shoulder abduction muscle endurance measured using isokinetic dynamometry |
author |
Micheletti, J. K. [UNESP] |
author_facet |
Micheletti, J. K. [UNESP] Andersen, L. L. Machado, A. F. Lopes, J. S.S. Souto, L. R. Pastre, C. M. [UNESP] |
author_role |
author |
author2 |
Andersen, L. L. Machado, A. F. Lopes, J. S.S. Souto, L. R. Pastre, C. M. [UNESP] |
author2_role |
author author author author author |
dc.contributor.none.fl_str_mv |
Universidade Estadual Paulista (Unesp) National Research Centre for the Working Environment Aalborg University Jacarezinho Mato Grosso |
dc.contributor.author.fl_str_mv |
Micheletti, J. K. [UNESP] Andersen, L. L. Machado, A. F. Lopes, J. S.S. Souto, L. R. Pastre, C. M. [UNESP] |
dc.subject.por.fl_str_mv |
Fatigue Muscle strength dynamometer Reproducibility of results Resistance training |
topic |
Fatigue Muscle strength dynamometer Reproducibility of results Resistance training |
description |
Objective: To evaluate reliability of performance and metabolic expenditure during a shoulder abduction endurance test with isokinetic dynamometer. Methods: A total of 28 healthy adults participated in 4 sessions (Orientation, Familiarization, Test and Retest). The muscle endurance test was performed using 50% of the individual maximal isometric voluntary contraction strength (21.9 ± 5.8 Nm). Participants performed repeated 0–90° shoulder abductions until exhaustion in the isokinetic dynamometer at a velocity of 60°/s. Values of time, repetition, rhythm and total work were analyzed. Results: For test and retest, respectively, time to fatigue (seconds) was 95.5 ± 37.6 and 91.1 ± 32.8 (P = 0.27), and repetitions were 31.4 ± 12.1 and 29.9 ± 10.6 (P = 0.23). Reliability was satisfactory [Time: ICC = 0.83 (95% CI = 0.66; 0.92); Repetition: ICC = 0.83 (95% CI = 0. 67; 0.92); Rhythm: ICC = 0.55 (95% CI = 0.24; 0.77); Total work: ICC = 0.85 (95% CI = 0.69; 0.93)]. Conclusion: The isokinetic test for shoulder muscle endurance at 50% of maximal muscle strength has good reliability. |
publishDate |
2021 |
dc.date.none.fl_str_mv |
2021-06-25T10:44:43Z 2021-06-25T10:44:43Z 2021-06-01 |
dc.type.status.fl_str_mv |
info:eu-repo/semantics/publishedVersion |
dc.type.driver.fl_str_mv |
info:eu-repo/semantics/article |
format |
article |
status_str |
publishedVersion |
dc.identifier.uri.fl_str_mv |
http://dx.doi.org/10.1016/j.scispo.2020.09.005 Science and Sports, v. 36, n. 3, p. e111-e119, 2021. 1778-4131 0765-1597 http://hdl.handle.net/11449/206840 10.1016/j.scispo.2020.09.005 2-s2.0-85096125707 |
url |
http://dx.doi.org/10.1016/j.scispo.2020.09.005 http://hdl.handle.net/11449/206840 |
identifier_str_mv |
Science and Sports, v. 36, n. 3, p. e111-e119, 2021. 1778-4131 0765-1597 10.1016/j.scispo.2020.09.005 2-s2.0-85096125707 |
dc.language.iso.fl_str_mv |
eng fra |
language |
eng fra |
dc.relation.none.fl_str_mv |
Science and Sports |
dc.rights.driver.fl_str_mv |
info:eu-repo/semantics/openAccess |
eu_rights_str_mv |
openAccess |
dc.format.none.fl_str_mv |
e111-e119 |
dc.source.none.fl_str_mv |
Scopus reponame:Repositório Institucional da UNESP instname:Universidade Estadual Paulista (UNESP) instacron:UNESP |
instname_str |
Universidade Estadual Paulista (UNESP) |
instacron_str |
UNESP |
institution |
UNESP |
reponame_str |
Repositório Institucional da UNESP |
collection |
Repositório Institucional da UNESP |
repository.name.fl_str_mv |
Repositório Institucional da UNESP - Universidade Estadual Paulista (UNESP) |
repository.mail.fl_str_mv |
|
_version_ |
1808128804041785344 |