Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães

Detalhes bibliográficos
Autor(a) principal: Passareli, João Victor Goulart Consoni
Data de Publicação: 2019
Tipo de documento: Dissertação
Idioma: por
Título da fonte: Biblioteca Digital de Teses e Dissertações da UNOESTE
Texto Completo: http://bdtd.unoeste.br:8080/jspui/handle/jspui/1231
Resumo: The aim of this study was to compare the accuracy of Tonovet and Tonovet Plus (rebound), Tono-Pen Avia Vet (applanation) and Kowa (Goldmann applanation) tonometers in dogs. Intraocular pressure (IOP) was measured in 130 eyes of 65 dogs. A post-mortem study was performed comparing manometry versus tonometry values and calculating the correlation coefficient (r2), an in vivo study comparing actual IOP (manometry) with tonometers and an outpatient study in healthy eyes and eyes with signs of glaucoma and uveitis. The results obtained in the postmortem study of (r2) values in decreasing order were: Kowa (0.989), Tonovet Plus (0.984), Tonovet (0.981) and Tono-Pen Avia Vet (0.847). The IOP values in mmHg in the in vivo study were: aneroid manometer (16.8 ± 2.5.7), Tonovet (18.1 ± 2.9), Tonovet Plus (20.6 ± 2.3), Tono Pen Avia Vet (17.1 ± 2.5) and Kowa (16.1 ± 1.7); healthy outpatients: Tonovet (16.8 ± 3.8), Tonovet Plus (19.2 ± 2.9), Tono-Pen Avia Vet (16.2 ± 2.4) and Kowa (15.0 ± 1.3); glaucoma: Tonovet (30.2 ± 3.5), Tonovet Plus (35.0 ± 6.1), Tono-Pen Avia Vet (29.5 ± 4.2) and Kowa (23.9 ± 5.0); and uveitis: Tonovet (14.2 ± 1.4), Tonovet Plus (17.6 ± 1.9), Tono-Pen Avia Vet (13.7 ± 2.1) and Kowa (12.6 ± 1.7). We can conclude that there was a strong correlation between IOP values and manometry in all tonometers. The highest values were with Tonovet Plus and the lowest with Kowa HA-2. All tonometers were accurate in measuring IOP in dogs, including the latest Tonovet Plus, which showed an excellent correlation coefficient.
id UOES_e5bb6d135ffff4a83ba3af56e86c6e70
oai_identifier_str oai:bdtd.unoeste.br:jspui/1231
network_acronym_str UOES
network_name_str Biblioteca Digital de Teses e Dissertações da UNOESTE
repository_id_str
spelling Andrade, Silvia Maria Caldeira Francohttp://lattes.cnpq.br/1455954245374682Cassu, Renata Navarrohttp://lattes.cnpq.br/1930132389295889Andrade , Alexandre Lima dehttp://lattes.cnpq.br/640417649530617138559357858http://lattes.cnpq.br/1111867734231962Passareli, João Victor Goulart Consoni2020-03-10T19:16:36Z2019-11-29Passareli, João Victor Goulart Consoni. Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães. 2019. 37f. Dissertação (Mestrado em Ciência Animal) - Universidade do Oeste Paulista, Presidente Prudente, 2019.http://bdtd.unoeste.br:8080/jspui/handle/jspui/1231The aim of this study was to compare the accuracy of Tonovet and Tonovet Plus (rebound), Tono-Pen Avia Vet (applanation) and Kowa (Goldmann applanation) tonometers in dogs. Intraocular pressure (IOP) was measured in 130 eyes of 65 dogs. A post-mortem study was performed comparing manometry versus tonometry values and calculating the correlation coefficient (r2), an in vivo study comparing actual IOP (manometry) with tonometers and an outpatient study in healthy eyes and eyes with signs of glaucoma and uveitis. The results obtained in the postmortem study of (r2) values in decreasing order were: Kowa (0.989), Tonovet Plus (0.984), Tonovet (0.981) and Tono-Pen Avia Vet (0.847). The IOP values in mmHg in the in vivo study were: aneroid manometer (16.8 ± 2.5.7), Tonovet (18.1 ± 2.9), Tonovet Plus (20.6 ± 2.3), Tono Pen Avia Vet (17.1 ± 2.5) and Kowa (16.1 ± 1.7); healthy outpatients: Tonovet (16.8 ± 3.8), Tonovet Plus (19.2 ± 2.9), Tono-Pen Avia Vet (16.2 ± 2.4) and Kowa (15.0 ± 1.3); glaucoma: Tonovet (30.2 ± 3.5), Tonovet Plus (35.0 ± 6.1), Tono-Pen Avia Vet (29.5 ± 4.2) and Kowa (23.9 ± 5.0); and uveitis: Tonovet (14.2 ± 1.4), Tonovet Plus (17.6 ± 1.9), Tono-Pen Avia Vet (13.7 ± 2.1) and Kowa (12.6 ± 1.7). We can conclude that there was a strong correlation between IOP values and manometry in all tonometers. The highest values were with Tonovet Plus and the lowest with Kowa HA-2. All tonometers were accurate in measuring IOP in dogs, including the latest Tonovet Plus, which showed an excellent correlation coefficient.O objetivo deste estudo foi comparar a acurácia dos tonômetros Tonovet e Tonovet Plus (rebote), Tono-Pen Avia Vet (aplanação) e Kowa (aplanação Goldmann) em cães. Foram mensurados a pressão intraocular (PIO) em 154 olhos de 77 cães. Através de um estudo post-mortem correlacionando os valores da manometria versus tonometria e calculando o coeficiente de correlação (r2), um estudo in vivo comparando a PIO real (manometria) com os tonômetros e um estudo ambulatorial em olhos saudáveis, e em olhos com sinais de glaucoma e uveíte. Os resultados obtidos no estudo post-mortem dos valores de (r2) em ordem decrescente foram: Kowa (0,989), Tonovet Plus (0,984), Tonovet (0,981) e Tono-Pen (0,847). Os valores da PIO em mmHg no estudo in vivo foram: manômetro aneroide (16,8 ± 2,5,7), Tonovet (18,1 ± 2,9), Tonovet Plus (20,6 ± 2,3), Tono-Pen (17,1 ± 2,5) e Kowa (16,1 ± 1.7); ambulatorial sadios: Tonovet (16,8 ± 3,8), Tonovet Plus (19,2 ± 2,9), Tono-Pen (16,2 ± 2,4) e Kowa (15,0 ± 1,3); glaucoma: Tonovet (30,2 ± 3,5), Tonovet Plus (35,0 ± 6,1), Tono-Pen (29,5 ± 4,2) e Kowa (23,9 ± 5,0); e uveíte: Tonovet (14,2 ± 1,4), Tonovet Plus (17,6 ± 1,9), Tono-Pen (13,7 ± 2,1) e Kowa (12,6 ± 1,7). Conclui-se que houve uma forte correlação entre os valores da PIO com a manometria em todos os tonômetros. Os valores mais altos de PIO foram com Tonovet Plus e os mais baixos com Kowa HA-2. Todos os tonômetros foram precisos na medição da PIO em cães, incluindo o mais recente, Tonovet Plus, que mostrou um excelente coeficiente de correlação.Submitted by Michele Mologni (mologni@unoeste.br) on 2020-03-10T19:16:36Z No. of bitstreams: 1 João Victor Goulart Consoni Passareli.pdf: 1141173 bytes, checksum: bce2f7ba9618dc0f43f69b5e50cb8ac5 (MD5)Made available in DSpace on 2020-03-10T19:16:36Z (GMT). No. of bitstreams: 1 João Victor Goulart Consoni Passareli.pdf: 1141173 bytes, checksum: bce2f7ba9618dc0f43f69b5e50cb8ac5 (MD5) Previous issue date: 2019-11-29application/pdfhttp://bdtd.unoeste.br:8080/jspui/retrieve/3558/Jo%c3%a3o%20Victor%20Goulart%20Consoni%20Passareli.pdf.jpgporUniversidade do Oeste PaulistaMestrado em Ciência AnimalUNOESTEBrasilMestrado em Ciência AnimalTonometria de aplanação, manometria direta, cães, tonometria de Goldmann, tonometria de rebote.Applanation tonometry, direct manometry, dogs, Goldmann tonometry rebound tonometry.CIENCIAS AGRARIAS::MEDICINA VETERINARIAComparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cãesComparison between Tonovet, Tonovet Plus, Tono-Pen Avia Vet and Kowa HA-2 portable tonometers for measuring intraocular pressure in dogsinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/masterThesis18867256397436141355005006001886725639743614135453670264235017319info:eu-repo/semantics/openAccessreponame:Biblioteca Digital de Teses e Dissertações da UNOESTEinstname:Universidade do Oeste Paulista (UNOESTE)instacron:UNOESTETHUMBNAILJoão Victor Goulart Consoni Passareli.pdf.jpgJoão Victor Goulart Consoni Passareli.pdf.jpgimage/jpeg3383http://bdtd.unoeste.br:8080/tede/bitstream/jspui/1231/3/Jo%C3%A3o+Victor+Goulart+Consoni+Passareli.pdf.jpgc22d6efc9737997042c03dc13d74183eMD53ORIGINALJoão Victor Goulart Consoni Passareli.pdfJoão Victor Goulart Consoni Passareli.pdfapplication/pdf1141173http://bdtd.unoeste.br:8080/tede/bitstream/jspui/1231/2/Jo%C3%A3o+Victor+Goulart+Consoni+Passareli.pdfbce2f7ba9618dc0f43f69b5e50cb8ac5MD52LICENSElicense.txtlicense.txttext/plain; charset=utf-82067http://bdtd.unoeste.br:8080/tede/bitstream/jspui/1231/1/license.txt47745281809acb27fb322a97f2d9cb88MD51jspui/12312020-03-11 01:00:11.266oai:bdtd.unoeste.br: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 Digital de Teses e Dissertaçõeshttp://bdtd.unoeste.br:8080/jspui/PUBhttp://bdtd.unoeste.br:8080/oai/requestbdtd@unoeste.bropendoar:2020-03-11T04:00:11Biblioteca Digital de Teses e Dissertações da UNOESTE - Universidade do Oeste Paulista (UNOESTE)false
dc.title.por.fl_str_mv Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães
dc.title.alternative.eng.fl_str_mv Comparison between Tonovet, Tonovet Plus, Tono-Pen Avia Vet and Kowa HA-2 portable tonometers for measuring intraocular pressure in dogs
title Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães
spellingShingle Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães
Passareli, João Victor Goulart Consoni
Tonometria de aplanação, manometria direta, cães, tonometria de Goldmann, tonometria de rebote.
Applanation tonometry, direct manometry, dogs, Goldmann tonometry rebound tonometry.
CIENCIAS AGRARIAS::MEDICINA VETERINARIA
title_short Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães
title_full Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães
title_fullStr Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães
title_full_unstemmed Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães
title_sort Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães
author Passareli, João Victor Goulart Consoni
author_facet Passareli, João Victor Goulart Consoni
author_role author
dc.contributor.advisor1.fl_str_mv Andrade, Silvia Maria Caldeira Franco
dc.contributor.advisor1Lattes.fl_str_mv http://lattes.cnpq.br/1455954245374682
dc.contributor.referee1.fl_str_mv Cassu, Renata Navarro
dc.contributor.referee1Lattes.fl_str_mv http://lattes.cnpq.br/1930132389295889
dc.contributor.referee2.fl_str_mv Andrade , Alexandre Lima de
dc.contributor.referee2Lattes.fl_str_mv http://lattes.cnpq.br/6404176495306171
dc.contributor.authorID.fl_str_mv 38559357858
dc.contributor.authorLattes.fl_str_mv http://lattes.cnpq.br/1111867734231962
dc.contributor.author.fl_str_mv Passareli, João Victor Goulart Consoni
contributor_str_mv Andrade, Silvia Maria Caldeira Franco
Cassu, Renata Navarro
Andrade , Alexandre Lima de
dc.subject.por.fl_str_mv Tonometria de aplanação, manometria direta, cães, tonometria de Goldmann, tonometria de rebote.
topic Tonometria de aplanação, manometria direta, cães, tonometria de Goldmann, tonometria de rebote.
Applanation tonometry, direct manometry, dogs, Goldmann tonometry rebound tonometry.
CIENCIAS AGRARIAS::MEDICINA VETERINARIA
dc.subject.eng.fl_str_mv Applanation tonometry, direct manometry, dogs, Goldmann tonometry rebound tonometry.
dc.subject.cnpq.fl_str_mv CIENCIAS AGRARIAS::MEDICINA VETERINARIA
description The aim of this study was to compare the accuracy of Tonovet and Tonovet Plus (rebound), Tono-Pen Avia Vet (applanation) and Kowa (Goldmann applanation) tonometers in dogs. Intraocular pressure (IOP) was measured in 130 eyes of 65 dogs. A post-mortem study was performed comparing manometry versus tonometry values and calculating the correlation coefficient (r2), an in vivo study comparing actual IOP (manometry) with tonometers and an outpatient study in healthy eyes and eyes with signs of glaucoma and uveitis. The results obtained in the postmortem study of (r2) values in decreasing order were: Kowa (0.989), Tonovet Plus (0.984), Tonovet (0.981) and Tono-Pen Avia Vet (0.847). The IOP values in mmHg in the in vivo study were: aneroid manometer (16.8 ± 2.5.7), Tonovet (18.1 ± 2.9), Tonovet Plus (20.6 ± 2.3), Tono Pen Avia Vet (17.1 ± 2.5) and Kowa (16.1 ± 1.7); healthy outpatients: Tonovet (16.8 ± 3.8), Tonovet Plus (19.2 ± 2.9), Tono-Pen Avia Vet (16.2 ± 2.4) and Kowa (15.0 ± 1.3); glaucoma: Tonovet (30.2 ± 3.5), Tonovet Plus (35.0 ± 6.1), Tono-Pen Avia Vet (29.5 ± 4.2) and Kowa (23.9 ± 5.0); and uveitis: Tonovet (14.2 ± 1.4), Tonovet Plus (17.6 ± 1.9), Tono-Pen Avia Vet (13.7 ± 2.1) and Kowa (12.6 ± 1.7). We can conclude that there was a strong correlation between IOP values and manometry in all tonometers. The highest values were with Tonovet Plus and the lowest with Kowa HA-2. All tonometers were accurate in measuring IOP in dogs, including the latest Tonovet Plus, which showed an excellent correlation coefficient.
publishDate 2019
dc.date.issued.fl_str_mv 2019-11-29
dc.date.accessioned.fl_str_mv 2020-03-10T19:16:36Z
dc.type.status.fl_str_mv info:eu-repo/semantics/publishedVersion
dc.type.driver.fl_str_mv info:eu-repo/semantics/masterThesis
format masterThesis
status_str publishedVersion
dc.identifier.citation.fl_str_mv Passareli, João Victor Goulart Consoni. Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães. 2019. 37f. Dissertação (Mestrado em Ciência Animal) - Universidade do Oeste Paulista, Presidente Prudente, 2019.
dc.identifier.uri.fl_str_mv http://bdtd.unoeste.br:8080/jspui/handle/jspui/1231
identifier_str_mv Passareli, João Victor Goulart Consoni. Comparação entre os tonômetros portáteis Tonovet, Tonovet Plus, Tono-Pen Avia Vet e Kowa HA-2 na mensuração da pressão intraocular em cães. 2019. 37f. Dissertação (Mestrado em Ciência Animal) - Universidade do Oeste Paulista, Presidente Prudente, 2019.
url http://bdtd.unoeste.br:8080/jspui/handle/jspui/1231
dc.language.iso.fl_str_mv por
language por
dc.relation.program.fl_str_mv 1886725639743614135
dc.relation.confidence.fl_str_mv 500
500
600
dc.relation.department.fl_str_mv 1886725639743614135
dc.relation.cnpq.fl_str_mv 453670264235017319
dc.rights.driver.fl_str_mv info:eu-repo/semantics/openAccess
eu_rights_str_mv openAccess
dc.format.none.fl_str_mv application/pdf
dc.publisher.none.fl_str_mv Universidade do Oeste Paulista
dc.publisher.program.fl_str_mv Mestrado em Ciência Animal
dc.publisher.initials.fl_str_mv UNOESTE
dc.publisher.country.fl_str_mv Brasil
dc.publisher.department.fl_str_mv Mestrado em Ciência Animal
publisher.none.fl_str_mv Universidade do Oeste Paulista
dc.source.none.fl_str_mv reponame:Biblioteca Digital de Teses e Dissertações da UNOESTE
instname:Universidade do Oeste Paulista (UNOESTE)
instacron:UNOESTE
instname_str Universidade do Oeste Paulista (UNOESTE)
instacron_str UNOESTE
institution UNOESTE
reponame_str Biblioteca Digital de Teses e Dissertações da UNOESTE
collection Biblioteca Digital de Teses e Dissertações da UNOESTE
bitstream.url.fl_str_mv http://bdtd.unoeste.br:8080/tede/bitstream/jspui/1231/3/Jo%C3%A3o+Victor+Goulart+Consoni+Passareli.pdf.jpg
http://bdtd.unoeste.br:8080/tede/bitstream/jspui/1231/2/Jo%C3%A3o+Victor+Goulart+Consoni+Passareli.pdf
http://bdtd.unoeste.br:8080/tede/bitstream/jspui/1231/1/license.txt
bitstream.checksum.fl_str_mv c22d6efc9737997042c03dc13d74183e
bce2f7ba9618dc0f43f69b5e50cb8ac5
47745281809acb27fb322a97f2d9cb88
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
repository.name.fl_str_mv Biblioteca Digital de Teses e Dissertações da UNOESTE - Universidade do Oeste Paulista (UNOESTE)
repository.mail.fl_str_mv bdtd@unoeste.br
_version_ 1766605150013620224